United Technologies interlogix ACL805SUW-RDMF Assembly instructions

© 2017 UTC Fire & Security. All rights reserved. 1 / 6 2017-10-13
ACL805SUW-RDMF
Reader Installation Sheet
EN
Surface Mount Keypad with Mifare reader
Figure 1: Angled front view
Mounting
Figure 2: Mounting instructions
3(3 x 30mm)
1 (M3 x 6mm)
Description
The ACL805SUW-RDMF is a Multiprotocol
digital keypad and Mifare reader for access
control applications with backlit keys and
selectable output protocol. These surface
mount readers includes a buzzer and a tri-
color LED for state indication (access
granted, access denied or idle).
ACL805SUW-RDMF is capable of reading
Mifare cards/fobs (13.56 MHz).

© 2017 UTC Fire & Security. All rights reserved. 2 / 6 2017-10-13
Wiring
Figure 3: Wiring instructions
Specifications
Operating voltage
9 to 14 VDC
Current consumption
210 mA at 12 VDC
Interface Mifare Reader
Wiegand 32 or 56 bit,
according to the ID length of the card
Wiegand 32 description
32 data bits
Pulse width: 100 µs
Pause: 1 ms
Wiegand 56 description
56 data bits
Pulse width: 100 µs
Pause: 1 ms
Interface Keypad
Wiegand 26, 30, 34, 40, 42, 58 bit,
8 bit per key, 6 bit per key, 4 bit per key
Wiegand 26 description
even parity + 24 data bits + odd parity
Pulse width: 100 µs
Pause: 1 ms
P1 = even parity calculated over the bits 2 to 13
P2 = odd parity calculated over the bits 14 to 25
Wiegand 30 description
even parity + 28 data bits + odd parity
Pulse width: 100 µs
Pause: 1 ms
P1 = even parity calculated over the bits 2 to 15
P2 = odd parity calculated over the bits 16 to 29
Wiegand 34 description
even parity + 32 data bits + odd parity
Pulse width: 100 µs
Pause: 1 ms
P1 = even parity calculated over the bits 2 to 17
P2 = odd parity calculated over the bits 18 to 33
Wiegand 40 description
even parity + 38 data bits + odd parity
Pulse width: 100 µs
Pause: 1 ms
P1 = even parity calculated over the bits 2 to 20
P2 = odd parity calculated over the bits 21 to 39
Wiegand 42 description
even parity + 40 data bits + odd parity
Pulse width: 100 µs
Pause: 1 ms
P1 = even parity calculated over the bits 2 to 21
P2 = odd parity calculated over the bits 22 to 41
1
tamp
Tamper
2
tamp
Tamper
3
LG-
LED Green minus
4
LR-
LED Red minus
5
GND
Ground
6
+12 V
9 to 14 VDC
7
D0
Data 0
8
D1
Data 1
gray
blue
yellow
orange
black
red
green
white
1
2
3
4
5
6
7
8
LR-
D1
D0
tamp
GND
+12 V
LG-
tamp

© 2017 UTC Fire & Security. All rights reserved. 3 / 6 2017-10-13
Wiegand 58 description
even parity + 56 data bits + odd parity
Pulse width: 100 µs
Pause: 1 ms
P1 = even parity calculated over the bits 2 to 29
P2 = odd parity calculated over the bits 30 to 57
Wiegand 8 bit per key description
8 data bits (sent on each key press)
Pulse width: 100 µs
Pause: 1 ms
Wiegand 6 bit per key description
6 data bits (sent on each key press)
Pulse width: 100 µs
Pause: 1 ms
Wiegand 4 bit per key description
4 data bits (sent on each key press)
Pulse width: 100 µs
Pause: 1 ms
Read range
Up to 6 cm,
depending on the card type
PIN Code length
1 to 8 digits
LED control
Yes, by wires
LED
Green : Externally controlled
Red : Externally controlled
Orange : Idle, Key press and Menu
Tamper
Yes
Cable distance
50 m according to Wiegand standard
Panel connection
Cable, 1 m
Material of design housing
ABS
Dimensions (W x H x D)
100 x 94 x 30 mm
Operating Temperature
Relative humidity
−20 to +50°C
0 to 95% noncondensing
IP rating
IP65
Color
-S = Silver, -G = Grey
Weight (shipping)
Weight (product)
550 g
250 g
Backlight and Buzzer
1. Backlight in idle mode Orange ON/OFF
2. Buzzer on card read ON/OFF

© 2017 UTC Fire & Security. All rights reserved. 4 / 6 2017-10-13
Settings in TruPortal Software
Settings in pcProxConfig Software
Go to System Administration/Card Formats.
Create custom Wiegand Format for Wiegand 56 bit and Wiegand 32 bits.
The reader will send the Wiegand format according to the card format. If the card presented has 56 bit
number, the reader will send Wiegand 56 bit. If the card presented has 32 bit number, the reader will send
Wiegand 32 bit.
Select Mifare CSN (Philips, NXP) as card type.
Use these settings in the pcProxConfig Software when reading Mifare Card via the TP-RDR-LRN desktop
Reader.

© 2017 UTC Fire & Security. All rights reserved. 5 / 6 2017-10-13
Keypad programming flowchart
Entering Menu is always done with B(3 s) + 000000 if the Master Code is not changed.
Submenu 1 - Change Master Code. The Master Code must be 6 digits. After enrolling new Master Code the
ACL875W automatically exits the Menu and the new master code must be typed to enter the menu.
Submenu 2 - Select Type of Wiegand. The Wiegand selected must be the same as the controller’s Wiegand Input
where the ACL805SUW-RDMF Keypad is being connected. Example: If you use a controller that recognizes Wiegand
34 bit, then enter the menu of ACL805SUW-RDMF, press 2, then press 3.
Submenu 3 - Select Output Protocol. Keypad have the following outputs:
3-1 Single Wiegand - Keypad will send code in wiegand format
3-3 Clock & Data - Keypad will send the code in Clock & Data format
3-5 8 bit per key - Each key press will be sent as 8 bit data immediately. Key press will be sent as following table:
3-6 6 bit per key - Each key press will be sent as 6 bit data immediately.
3-7 4 bit per key - Each key press will be sent as 4 bit data immediately.
Submenu 4 - PIN Code Length. If “0” is selected, then any PIN Code with any length can be sent, but the PIN Code is
typed with “A” for confirmation (ex. 123 + A). If 1 to 8 is selected the PIN Code length is set by the number selected.
Submenu 6 - Presets. The Presets are set of preprogrammed parameters for easy programming.
6-1 “Wiegand 26 bit Normal” - Type: Wiegand 26 bit; Output: Single Wiegand; PIN Length: 4 digits;
6-2 “Wiegand 34 bit Normal” - Type: Wiegand 34 bit; Output: Single Wiegand; PIN Length: 4 digits;
Submenu 7 - Site Code Length. Set the code length sent to Host. Default is “0”. To be used only in specific cases.
Submenu 8 - Enter Site Code. Put the site code always in 5 digit format (ex. 00170).
Key
0
1
2
3
4
5
6
7
8
9
A
B
Wiegand output
240
225
210
195
180
165
150
135
120
105
90
75

© 2017 UTC Fire & Security. All rights reserved. 6 / 6 2017-10-13
Submenu 9 - Turns ON/OFF the backlight in idle mode, buzzer on key press, parity bit.
Reset Master Code
1. Disconnect Power
2. Press and hold “A” and reconnect Power.
3. Hold the “A” Key for at least 3 seconds.
Default Master Code: 000000
Manufacturer
UTC Fire & Security Americas Corporation, Inc.
1275 Red Fox Rd., Arden Hills, MN 55112-6943, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Version
This document applies to ACL805SUW-RDMF hardware
Certification and Regulatory
information
This product herewith complies with requirements of EMC directive 2014/30/EU, Radio Equipment Directive
2014/53/EU. In addition it complies with RoHS directive EN50581:2012
Contact information
https://firesecurityproducts.comor www.interlogix.com
Product Warnings
and Disclaimers
THESE PRODUCTS ARE INTENDED FOR SALE TO, AND INSTALLATION BY, AN EXPERIENCED SECURITY
PROFESSIONAL. UTC FIRE & SECURITY CANNOT PROVIDE ANY ASSURANCE THAT ANY PERSON
OR ENTITY BUYING ITS PRODUCTS, INCLUDING ANY “AUTHORIZED DEALER”, IS PROPERLY
TRAINED OR EXPERIENCED TO CORRECTLY INSTALL SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers and product safety information, please check
https://www.utcfssecurityproducts.eu/productwarning/ or scan the following code: