SETTING THE KEYPAD ADDRESS
T e keypad can eit er be set for an address of 00-30, or to
t e non-addressable mode (31). T e keypad's default
address is 31.
To c ange t e keypad's address, do t e following:
1. Enter address mode: Power up t e keypad. Wit in 60
seconds of power-up, press and old down t e [1] and [3]
keys at t e same time for 3 seconds. (If unable to enter
address mode, power up and try again.)
T e current keypad address will be displayed, and t e
cursor will be under t e "tens" digit. If 10 seconds ave
passed wit no key entry, t e keypad automatically exits
address mode. You must power down, power up and
start address mode again.
NOTE
NOTENOTE
NOTE: T e keypad will not enter address mode if t e
panel to w ic it is connected is in programming mode.
2. Set t e current address to "00": Press [0] to clear t e
current "tens" digit. T e cursor will move to t e "ones"
digit position. Press [0] to clear t e current "ones" digit.
T e cursor will move back to t e "tens" digit position.
3. Enter t e keypad's address: Enter t e proper "tens" digit
of t e keypad's address. T e cursor will move to t e
"ones" digit position. Enter t e proper "ones" digit of t e
keypad's address. Note t at address "31" sets t e
keypad to non-addressable mode.
4. Exit address mode:
Press [] to save t e displayed address and exit address
mode.
VIEWING THE KEYPAD ADDRESS
Press and old down t e [1] and [3] keys at t e same time
for about 3 seconds. T e current address is displayed. No
key entry is allowed. Press any key to exit or wait 10
seconds to exit viewing mode.
FUNCTION KEY LABELS
A set of ad esive-backed labels wit some typical function
symbols (i.e., fire, police, personal emergency, etc.) is
provided. T ese labels can be placed on or next to t e keys
to identify eac key's function for t e end user (as
determined by t e control panel's capability and
programming; see t e control's instructions).
OPERATING THE KEYPAD
For operating instructions, see t e User Guide for t e
control panel used wit t is keypad.
SPECIFICATIONS
P ysical:
P ysical:P ysical:
P ysical:
6150: 4-7/8"H x 6-1/4"W x 1"D
6160: 5-5/16"H x 7-3/8"W x 1-3/16"D
Displays:
Displays:Displays:
Displays:
6150: Fixed-Word LCD (backlit).
6160: 2 x 16 alp a-numeric supertwist LCD,
backlit.
Sounder:
Sounder:Sounder:
Sounder:
6150: Piezo-electric (fire alarm is loud, pulsing
single tone; (all Keypads) burglary alarm is
loud, continuous, dual tone).
6160: Speaker.
Voltage:
Voltage:Voltage:
Voltage: 12VDC (power-limited)
Current:
Current:Current:
Current:
6150: 70mA (ARMED LED lit, LCD backlig t and
sounder on), reduces to 40mA w en panel is
operating in standby mode (backlig t off).
6160: 150mA (ARMED LED lit, LCD backlig t
and sounder on), reduces to 40mA w en
panel is operating in standby mode
(backlig t off).
NFPA
NFPANFPA
NFPA-
--
-72
7272
72 Compliant.
REFER TO INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED FOR WARRANTY
INFORMATION AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM.
The product should not be disposed of with other household waste. Check for the nearest authorized collection centers or authorized recyclers. The
correct disposal of end-of-life equipment will help prevent potential negative consequences for the environment and human health.
Any attempt to reverse-engineer this device by decoding proprietary protocols, de-compiling firmware, or any similar actions is strictly prohibited.
Responsible Party / Issuer of Supplier’s Declaration of Conformity: Ademco Inc., a subsidiary of Resideo Technologies, Inc., 2 Corporate Center
Drive., Melville, NY 11747, Ph: 516-577-2000
.
WARRANTY INFORMATION
For the latest warranty information, please go to:
http://www.security.honeywellhome.com/warranty
The Honeywell Home Trademark is used under license from Honeywell International Inc.
This product is manufactured by Resideo Technologies, Inc. and its affiliates
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
© 2020 Resideo Technologies, Inc.
www.resideo.com
K3590-ADV5D 9/10 Rev D