© 2019 UTC Fire & Security Americas Corporation, Inc. 1 / 2 P/N 1038436 • REV C • ISS 16JUL19
5500 Moisture Detection Series Installation
Instructions
Introduction
The 5500 Moisture Detection Series is designed to respond to
the presence of water and other nonflammable conductive
liquids. It is connected in the closed loop of an alarm system.
You can use up to four surface-mount 5515 sensors with the
5501 moisture processor.
You can use the processor with any closed loop control panel,
dialer, or wireless transmitter input circuit. The processor
comes with internal lithium batteries with an anticipated life of
10 to 15 years. The processor provides flexibility in mounting
with no need for an external power source and minimal
required wiring.
Operation
A time delay circuit is provided to reduce the chance of false
alarms. The processor requires the presence of moisture for
ten seconds before going into alarm mode. It will stay in alarm
mode until the moisture is removed from the sensor. When
tripped, the LED will flash at two-second intervals until the
sensor is dry. Optical coupling between sensor input and
processor output circuits provides isolation from ground.
Installation
To install the series, do the following:
1. Insert a small, flat-bladed screwdriver in the slot at the top
or bottom of the processor and pry the cover off the base.
2. Mount the processor using the mounting holes shown in
Figure 1 below.
3. Mount the 5515 sensors to any surface and in any
position, using screws or double-sided tape.
Wiring
Wire the sensors in parallel (Figure 1 below). You do not need
to observe polarity. The connection for output on the
processor, however, is polarity sensitive. Trigger the processor
and allow the control panel, dialer, or transmitter to operate to
verify the connection.
Testing
Press the test button (Figure 1 below) for 15 seconds to
simulate the presence of water and activate the processor (the
LED will flash). Release the button to restore the processor to
normal operation.
Figure 1: 5500 moisture detection series
2 5500 Moisture Detection Series Installation Instructions
Dimensions
Figure 2: Dimensions
Specifications
Loop type
Closed
Battery type
Lithium
Battery life
Approximately 10 to 15 years
Alarm response
10 seconds delay, then on as long as wet
Test button
Simulates moisture for test
LED
Flashes every 2 seconds on alarm
Trigger response
500 K ohm
Sensor isolation from
ground
Photo coupled
Sensing circuit
AC to eliminate electrolysis (1 Hz)
Cable Length
100 ft. (30 m) maximum
Loop resistance
10 ohms maximum (nonalarm)
1 M ohm minimum (alarm)
Operating temperature
5501 processor
5515 sensors
0 to 125°F (-17 to 51°C)
33 to 180°F (0 to 82°C)
Number of sensors per
processor
4 maximum
Ordering information
Model #
Description
Loop type
Color
Lead
5501
Moisture
processor
Closed
Mahogany
brown
Terminals
5515
Surface-
mount sensor
NA
Gray
10 ft. (3 m)
Regulatory information
Manufacturer
PLACED ON THE MARKET BY:
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 28092,
USA
AUTHORIZED EU REPRESENTATIVE:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Product warnings
and disclaimers
THESE PRODUCTS ARE INTENDED FOR
SALE TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. UTC FIRE & SECURITY
CANNOT PROVIDE ANY ASSURANCE THAT
ANY PERSON OR ENTITY BUYING ITS
PRODUCTS, INCLUDING ANY “AUTHORIZED
DEALER” OR “AUTHORIZED RESELLER”, IS
PROPERLY TRAINED OR EXPERIENCED TO
CORRECTLY INSTALL FIRE AND SECURITY
RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/ or scan the QR code.
Contact information
www.utcfireandsecurity.com or www.interlogix.com
For customer support, see www.interlogix.com/customer-
support

This manual suits for next models

2

Other United Technologies Security Sensor manuals

United Technologies Interlogix DDI602U-F1 Assembly instructions

United Technologies

United Technologies Interlogix DDI602U-F1 Assembly instructions

United Technologies Interlogix TX-E201 Assembly instructions

United Technologies

United Technologies Interlogix TX-E201 Assembly instructions

United Technologies Interlogix TX-E221 Assembly instructions

United Technologies

United Technologies Interlogix TX-E221 Assembly instructions

United Technologies Interlogix 5500 Series User manual

United Technologies

United Technologies Interlogix 5500 Series User manual

United Technologies Interlogix RF440I4 Assembly instructions

United Technologies

United Technologies Interlogix RF440I4 Assembly instructions

United Technologies Edwards SIGA-OSHD Assembly instructions

United Technologies

United Technologies Edwards SIGA-OSHD Assembly instructions

United Technologies Interlogix RF430I4 Assembly instructions

United Technologies

United Technologies Interlogix RF430I4 Assembly instructions

United Technologies interlogix DDI602 Assembly instructions

United Technologies

United Technologies interlogix DDI602 Assembly instructions

United Technologies Interlogix TX-E231 Assembly instructions

United Technologies

United Technologies Interlogix TX-E231 Assembly instructions

United Technologies Edwards Signature SIGA-OSHD Assembly instructions

United Technologies

United Technologies Edwards Signature SIGA-OSHD Assembly instructions

Popular Security Sensor manuals by other brands

NORLUX Ultranik UC01 installation manual

NORLUX

NORLUX Ultranik UC01 installation manual

Optex VX Infinity Series installation instructions

Optex

Optex VX Infinity Series installation instructions

UEi COA1PK instruction manual

UEi

UEi COA1PK instruction manual

Velleman PEREL EMS105 user manual

Velleman

Velleman PEREL EMS105 user manual

C-LOGIC 645-MD instruction manual

C-LOGIC

C-LOGIC 645-MD instruction manual

BEA IXIO-SO1 I user guide

BEA

BEA IXIO-SO1 I user guide

AdirPro MC-10 quick start guide

AdirPro

AdirPro MC-10 quick start guide

IOTA ILB-CP20-HE-SD-A instruction manual

IOTA

IOTA ILB-CP20-HE-SD-A instruction manual

hyfire HFI-DPT-05 instruction manual

hyfire

hyfire HFI-DPT-05 instruction manual

Medem AGDS-MC installation instructions

Medem

Medem AGDS-MC installation instructions

GREISINGER GMSD ex Series operating manual

GREISINGER

GREISINGER GMSD ex Series operating manual

Ecolink TX-E611 Installation sheet

Ecolink

Ecolink TX-E611 Installation sheet

Cardin Elettronica Mini CDR Series manual

Cardin Elettronica

Cardin Elettronica Mini CDR Series manual

Axis APS400W instruction manual

Axis

Axis APS400W instruction manual

PCB Piezotronics IMI SENSORS 641B01 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS 641B01 Installation and operating manual

EMX Industries USVD-4X instruction manual

EMX Industries

EMX Industries USVD-4X instruction manual

Maclean Energy MCE133 manual

Maclean Energy

Maclean Energy MCE133 manual

SECO-LARM ENFORCER RM-R100-TBQ user manual

SECO-LARM

SECO-LARM ENFORCER RM-R100-TBQ user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.