8. Start-up and Maintenance
Note:
1.)If no water can be pumped in 5 minutes after the pump is filled with water
and started up, turn off and refill the pump, or check the leakage of inlet
pipelines, then restart the pump.
For frost and freeze protection, remove the discharge plug on the air tank
and drain the water in the pump chamber completely. Before restart the
pump, it’s necessary to remove the filling plug, fill the pump fully with water,
and then screw the filling plug.
In case of no use for a long time, discharge the water in the pump chamber
and store the pump in a dry, well-ventilated place.
If the ambient temperature is high, make sure the pump works in a well-
ventilated place to avoid electrical faults caused by dew on electrical parts.
In case of overheat or abnormal operation of the pump motor, cut off the
power supply immediately, and check the faults according to the following
form.
2).
3).
4).
5).
Do not switch on the pump if the pump chamber is not fully
filled with water.
Do not touch the electric pump unless the power of pump is
cut off for over 5 minutes.
Do not remove the pump bonnet unless the water in pump
chamber is completely drained.
Stir the fan with a screwdriver to
check if the pump rotates flexibly
before startup. Remove the filling
plug and prime the pump
chamber fully with clean water,
then screw the filling plug. Keep
the valve wide opened during
startup. When the pump runs
normally, adjust the valve to the
required flow (The range of flow
and head is shown on the
nameplate).
1. Applications
It is applicable to household water supply, equipment support, well water
lifting, pipeline pressurization, garden watering, vegetable greenhouse
watering, fish farming and poultry raising, etc..
Transfer clean water and other non-corrosive liquids with low viscosity; do
not transport inflammable, explosive, gasified liquids and liquids containing
solid particles or fibers. The liquid PH value shall be between 6.5 and 8.5.
The pump can work automatically, equipped with pressure tank, pressure
switch and other necessary parts. Function features of the automatic pump
are as follows: when the power is on, turn on the water tap and the pump
will start working automatically; when the water tap is turned off, the pump
will stop working automatically. If a water tower is used along with the
automatic pump, connect to the upper limit switch and the pump will start or
stop working automatically with water level in the water tower.
Remark:
Read the instructions carefully and follow the rules for safe
operation.
The operator shall take full responsibility for personal injury,
pump damage and other property losses caused by violation
of safety cautions.
2. Model Description
XKJ x x
Pump body material: I (Cast Iron),
P (Plastic) or S (Stainless Steel)
Rated power (W)
Garden Jet Pump
A:
1. Drain Plug
2. Electric pump
3. Water tap
4. Outlet pipe
Incorrect Installation Diagram
Correct Installation Diagram A
B
B2B1
5. Filling plug
6. Tie-in
7. Inlet pipe
8. Foot valve
36
Do not use soft rubber tube for inlet
pipeline during pump installation.
The bottom valve shall be vertically
installed with a distance of 30 cm
from the water bottom to avoid
suction of sediment (A2).
All connections of the inlet pipeline
must be sealed. To ensure water
suction, it’s necessary to reduce the
quantity of bents of the pipeline.
The diameter of inlet pipeline must
not be less than that of the pump
inlet to avoid big hydraulic loss and
small water flow.
Pay attention to the water level
during operation. The bottom valve
shall not be above the water surface
(A1);
In case the inlet pipeline is more
than 10 m in length or over 4 m in
hoisting height, the diameter of the
inlet pipeline must be bigger than
that of the pump inlet.
Make sure that the pump is not
affected by the pipeline pressure
during pipeline installation.
It is recommended to install a filter
on inlet pipeline to avoid incoming of
solid particles to the electric pump.
Before first operation, the inlet
pipeline must be fully filled with
water and installed with a bottom
valve.
1.)
2).
3).
4).
5).
6).
7).
8).
Note for outlet pipeline installation:
The diameter of the outlet pipeline shall
be not less than that of the pump outlet
to reduce the pressure drop, high flow
rate and noise to the lowest level.
Notes for inlet pipeline installation:
9).
12
3
4
5
6
7
8
Max:8m
3. Technical Data
Max. flow: 53 L/min
Max. head: 30 m
Output power: 0.3 ~ 0.4 kW
Max. suction: 8 m
Protection class: IPX4
Insulation class: F
Max. ambient temperature: +40℃
4. Implementation Standards
IEC/EN 60335-1 Household and similar electrical appliances--safety
Part1: General requirements.
IEC/EN 60335-2-41 Household and similar electrical appliances--safety
Part2-41:Particular requirements for pump.
2006/95/EC Low voltage directive
5. Safety Precautions
Manual
ON OFF
OO
DANGEROUS
1. To ensure normal and safety operation of the electric
pump, read the manual carefully before use.
2. To avoid electric shock, make sure the pump is safely
grounded and equipped with an earth leakage circuit
breaker. Do not get the plug wet and do not use any
socket in an area with high humidity.
3. Do not touch the electric pump while working; do not
wash, swim near working area or let livestock into the
water to avoid accidents.