Unoisetion YH-5301S User manual

Unoisetion Cavitation 3D RF Wegiht Loss Cellulite Remove
Lipo Laser 650Nm Device
Model: YH-5301S

Chapter 1: Safety Warnings
I. Electricity & Machinery Safety
1.The machine is either 110V And 220V. So whatever the voltage u can use before
starting the machine.
2. Please keep the voltage at stable condition.
II. Contraindication Safety
1. People with heart disease, high blood pressure, or configured cardiac Pacemaker.
2. People with acute inflammation, asthma, deep vein thrombosis, thyroncus, cancer.
3. People with hemorrhagic diseases, trauma or who is bleeding.
4. Pregnant women
5. Medical plastic artificial or metal parts inside the body such as metal teeth or
silicone breast implants.
6. People with abnormal immune system.
7. People with numb or insensitive to heat.
8. If you are feeling unwell, Prohibited in the ears, nose, eye throat and do not use this
device in advance and tell your doctor.
9. Children under 12 years old are not allowed.
III.Treatment Safety
1. Treatment Time is less than 30mins/Body Part/Each Treatment.
2. The energy setting is from low to high gradually which should be subject to skin
comfortableness for different people.
3. The patient had better wear the protective eye glasses.
4. If you cannot tolerant heat or uncomfortable, please stop the treatment in advance
and turn to your doctor for help.
Chapter 2: Installment and Use
I .Working Condition
Using at normal temperatures and pressure. Please do not stay in too cold, too hot, too
dry and too wet

II. Technical Parameters
Parameters
Power supply Input:100V-240V
Power :190W
Uoisetion 40K Cavitation Head
Frequency:40KHz
Power:15W
Sextupolar 3D RF for Body
Freqeuncy:1MHz
Power:50W
Quadrupole RF with Vacuum
Freqeuncy:1MHz
Power:50W
Vacuum: <-80kPa
Pressure: >250kPa
Air flow: >10L/minute
Noise level: <70dB (30cm away)
Quadrupole 3D RF for face
Freqeuncy:1MHz
Power:30W
3D Bipolar RF
Freqeuncy:1MHz
Power:10W
Laser wavelength: 635nm ~650nm
Energy output :68 x 5mw
Mains power output: 100VA
Classification :Electrical Class 1, Type B applied part
Cooling requirements :Air cooled
Electrical requirements: 100v--240VTimer: 30 minutes adjustable

IV. How to install the Accessories?
V. Program Setting
1. Use the red power button to start the machine, the screen will show “Welcome”.

2. Click any place of the screen to enter into the main interface.
A. 40K Cavitation
1. Press button to enter into 40k unoisetion function display as bellow:

2. Please click to set working time.
3. Please click to increase or decrease the ENERGY
4. Please click and to chose working model.
5. Please click to start or pause function.
6. Please click to come back to the main function interface.
B. Body Vaccum & RF
1 Press button to enter into Body RF Vacuum operation display as bellow:

2. Please click to set working time.
3. Please click to increase or decrease the RF ENERGY.
4. Please click and to set the time for the
suction and release.
5. Please click M1, M2, M3, M4 to choose the model.
6. Please click to start or pause function.
7. Please click to come back to the main function interface.
C. BODY RF
1. Press button then login BODY RF operation display as bellow:

2. Please click to set working time.
3. Please click to increase or decrease the RF ENERGY.
4. Please click to control the led light on the head.
5. Please click to come back to the main function interface.
D. Face RF&BIO
1. Press button then login Face Radio Frequency&BIO operation
display

(Press botton to choose RF or bio function)
2. Please click to set working time.
3. Please click to increase or decrease the ENERGY.

4. Please click to start or pause function.
6. Please click to come back to the main function interface.
E. Eye Radio Frequency
1. Press button then login Eye Radio Frequency operation display.

(Press button to choose RF or BIO)
2. Please click to set working time.
3. Please click to increase or decrease the RF ENERGY.
4. Please click to start or pause function.
5. Please click to come back to the main function interface.
F. Lipo Laser
1. Press button to enter into Lipo Laser operation display as bellow.

2. Click“M1”, “M2 ” or “M3”to choose different treating modes. M1, M2, M3 (ps:
Mode 1, Mode 2, Mode 3 means different wave modes). M1 is continuous; M2 is
500ms( 2Hz); M3 is 100ms (10Hz).
3. WORKING TIME: click and to add or decrease time.
4. Click to start and stop.
5. Click to clear the energy settings.
6. Click back to the main menu.
7. Click to “+” and “-“ the energy.
The laser pads can all working together or work separately as you like.

1. Choose A, then all pads of A working together, Choose B, then all pads of B
working together.
2. Choose A and B, then all pads can working together.
3. If you choose any single one, then the pad can work separately. And each one can
be adjusted the energy.
About Treatment
1)Abdomen, thigh, buttock, arms slimming
Please clean the skin and then put the ultrasound gel on the treatment area, then turn on the
machine, set the time and energy. Please set the energy from low to high to get the best
comfortable temperature, then follow this steps:
1. Use the Body RF head 5 mins
2. Use the unoisetion 40k cavitation head 20-25min
3. Use the Body RF Vacuum head 10-15min
4. Use the Body RF head 15~20 min.
5. Use Lipo lasr pads around 25~30 min.
Work time: 2-3 times/ week
2)Face, eyes around, neck skin lifting:
Please clean the skin and then put the rf gel on the treatment area, then turn on the machine , set

the time and energy, pls set the energy from low to high to get the best comfortable temperature,
then follow this steps:
1. Use face radio frequency head for face for 15-20 min
2. Use eye radio frequency head for eye around for 10-15min
Work time: 2-3 times/ week
BUTTOCKS
ILLUSTRATIN of OPERATION
FACE
Treated time: 30 minutes
Massage the mandible center in circles to produce deep heat.
2. Massage lower jaw in lines.
3. Massage the triangle zone of both sides of the face in circles.
4. Massage from jaw to angulus oris to ear in lines.
THIGH

Treated time: 30 minutes
1. From down to upper, pushing to the groin to dredge the lymph.
2. From down to upper, circling push by anticlockwise can help decomposing
fatness.
3. Also can push by come-and-go to decompose fatness.
4. Pull from the knee and muscle texture to upper, can improve the curve.
Treated time: 20 to 30 minutes
1. Along the lymph direction, pulling to the waist.
2. From upper to down, by anticlockwise gesture, pull come-and-go.

3. Along the muscle of arm, pull up to lift and tight the muscle.
BACK
Treated time: 20 to 30 minutes
1. First by come-and-go, pushing the bladder nerve 2 to 3 times.
2. Circling by anticlockwise to stimulate the underarm lymph node.
3. On the back, by anticlockwise circling, can help to decompose the
fatness.
4. Using lymph drainage gesture, pull the toxin to the lymph node, can help
improving the back curve.


Table of contents