UR FOG Plus Series Guide


SUMMARY
1 Package contents.............................................................................page 2
2 Introduction of the product
................................................................
page 3
3 Conditions of use and warnings.....
....................................................
page 3
4 Installations tips for fogging systems....................
.............................
page 4
5 Technical specifications.....................................................................page 5
6 How to activate the system..............................................................page 6
7 Mains power and power supply connections.....................................page 7
8 Description of input and output connections......................................page 8
9 Connection examples........................................................................page 10
10 Shooting time settings ........................................................................page 12
11 Installation, fluid bag exchange and reset.........................................page 13
12 Front LEDS Meaning..........................................................................page 14
13 Maintenance
......................................................................................
page 15
14 Defects and possible solution...........................................................page 16
15 Warranty.............................................................................................page 18
16 Maintenance.....................................................................................page 19
The conditions of use will be automatically accepted by breaking the security labels on the product.
1 PACKAGE CONTENT
Inside the package you will find:
1 The Unit Modular CPlus .
2. One 750 ml bag. (Optional 1000 ml)
3. A window label to indicate the device installation.
4. Installation and use manual.
219
WARNING! All UR FOG fogging systems should only be used with UR FOG-branded u-
ids. It is strictly forbidden to use any uid not previously authorized in writing by UR FOG srl. DATE BATTERY EXCHANGE BAG EXCHANGE SIGNATURE
YES NO n. NO
YES NO n. NO
YES NO n. NO
YES NO n. NO
YES NO n. NO
YES NO n. NO
YES NO n. NO
YES NO n. NO
YES NO n. NO
YES NO n. NO
YES NO n. NO
YES NO n. NO
YES NO n. NO
YES NO n. NO
YES NO n. NO
YES NO n. NO
YES NO n. NO
YES NO n. NO
YES NO n. NO
It is mandatory to fill out this table in accordance
with the international rules
16 MAINTENANCE

2INTRODUCTION OF THE PRODUCT
Thank you for purchasing UR Fog product.
The great patented technological innovations such as the moduled liquid injection system, the revolutionary heating system, and the Acti-
veCloud ready technology make the Modular CPlus fog generators the best fog devices with the best performance in the security market.
- Simple: Machine easy to install and able to be integrated to any existing alarm system.
The fog generated by UR Fog does not create particular problems or injuries for a human being for a short stay in a fogged room if
the system is used according to the manufacturer’s recommendations. Generated fog is certified as safe for people and animals from an
authorized international certification company and is proved that it does not leave any residual. UR Fog systems are certified respecting
European laws and regulations. Any certifications required in specific countries are a responsibility of the distributor of that specific country.
The documents related to certifications can be requested by mail to [email protected]. It is not guaranteed by the manufacturer the use
of UR Fog system in the presence of objects that may be damaged anyway by the contact with substances based on glycol, water and
alcohol. Any employee or worker that may be exposed to fog must be warned in advance and must be checked for any allergy to the sub-
stances listed above. At the date of printing of this manual it has never been pointed out any problem related to any allergy. UR Fog is in
no way responsible for any damage or condition of use that has not been required and specifically approved by any specific written request
prior to the installation of its products. For fog fluid please refer to UR Fog fluid safety data sheet published on the website and carefully
read it at www.urfog.com. Contact a doctor if for any reason you swallow fog fluid or if after contact with eyes or skin you have any
kind of reaction, and in any case wash it immediately with water and soap. Do never stay for a long time in a room filled with fog. Do not
use charged bags that are not the ones suggested by UR Fog and never try to recharge them, they are made for a single use. Follow your
national rules for the dispose of empty bags. Keep UR Fog bags out of reach of babies and animals. The nozzle may be hot and touching
it may cause burns. Do not look directly into the nozzle. Never use UR Fog products for any purpose that is not related to protection from
thief or robbery (the choice of the conditions of use in case of robbery will be suggested by your security consultant).
Never use different fog fluids or add any other substance into the cylinders. Do not use or keep charged UR Fog machines in vehicles and
do never transport UR Fog before 24 hours since it has been shut off. During transport it must be not armed.
3
3CONDITIONS OF USE AND WARNINGS
18
15 WARRANTY
The warranty of UR Fog is two years and is handled directly from the dealer or authorized installer, so please contact your supplier to
take advantage of warranty with the copy of the purchase document that contains the serial number of the machine. Not included in the
warranty: moving parts and/or damages depending on the incorrect use unless it is found a manufacturing defect in origin. Liquid and bags
are not covered by warranty.
BY BREAKING THE SECURITY LABELS AND THE OPENING OF THE MACHINE YOU WILL ACCEPT WHAT
IS WRITTEN ON THIS MANUAL AND ON THE WEB SITE: www.urfog.com
UR Fog srl, Via Toscana n°38 - 10099 - San Mauro Torinese - Italy
Tel 011/01.33.037 Fax 011/01.33.005
RESELLER/INSTALLER STAMP
(company to contact for the warranty)
Serial number..........…………………………………………………………......................
Date of installation..………………………………………………………….......................
Signature of installer ………………………………………………………………………....
At the end of the installation, write down the identification number of
the machines, the date of the installation and sign in the dedicated spaces.
Legal office: Via Giacinto Collegno 11 - 10143 - Torino - Italy

4
4 INSTALLATION TIPS FOR FOGGING SYSTEMS
Please observe the following instructions for installing UR Fog:
1. The unit must be installed avoiding to obstruct escape routes.
2. Verify the fog does not limit the visibility near: stairs, landings, moving objects that may cause: falls down, injuries or any damage to
persons.
3. Do not look directly into the nozzle. Use only authorized fluids and original bags.
4. The heather box may reach high temperatures, touch it may cause burns.
5. When UR Fog produces fog avoid staying closer than 1 meter from the unit.
7. Report the Fog Unit installation to the firefighters in your area and eventually to other institutions if needed. Before testing the unit
remember to report it to the firefighters in your area to avoid false alarms.
8. Remember to stick on a window in a visible place the included warning label.
9. Do not move the machine when it is still hot.
10. It is necessary to add an external switch to separate the fog generator from the alarm system and it should be activated before
the maintenance to avoid that input tests, for example, can activate the fog generator.
11. Never direct the fog jet towards an object or a wall less than 2 meters away and if possible increase the suggested minimum distance.
Thanks to the power of the jet, UR Fog reaches and exceeds more than 10 meters away in the first 3 seconds from the point where the
machine is installed.
12. Setting the shooting time interval between the minimum and maximum shown in the shooting table, avoid “overshooting” even if the
produced fog is dry and generally doesn’t leave residue. A shot that goes far beyond the recommended seconds can create a residue
problems in the room.
13. UR Fog continues to be effective for up to 2 hours without 220V and 110V mains power thanks to the insulation system which
maintains the temperature in the heating system.
14. Install at an height of about 2,5 meters not to let it be reached, avoiding possible tampering.
15. The unit has a nozzle inclination of 15° oriented to the floor.
16. The main body of UR Fog, which has the heating system enclosed inside a metal frame, should not be opened unless by specific and
authorized service centers. Do not open and touch for any reason the insulation before 24 hours the unit has been shut off. The internal part
may reach really high temperature.
17. Do not activate the UR Fog machine before the installation is completed.
18. Insert the bag as last installation procedure.
19. When the installation is finished, always test the system with a trial shoot (suggested 4 seconds)
20. After connection to mains power at least one hour is necessary to reach the minimum temperature needed to generate fog.
21. Install UR Fog avoiding any obstacles in front of it which can prevent the spreading of the fog.
22. The external temperature of UR Fog can be higher from room temperature up to 50 °C.
23. Connecting to the mains the edge of a stranded conductor should not be soft-soldered
24. The UR Fog machine should not be exposed to water spray or dripping.
25. The content of fluid bags is meccanically pre-determined , the tollerance is in the range -10% +10%
26. Request to UR Fog or its distributors to take part in courses for installers to ensure the optimal installation of the equipment.
17
DEFECT FOUND POSSIBLE CAUSE POSSIBLE SOLUTION
Red front led ON
Bag changed ,reset needed
Follow instructions Paragraph 13
Unit ARMED
(BLUE LED ON)
but don’t execute trig command
Green front led is OFF
Unit still warming , wait max 120min. with the unit
connected to the mains power for 1st time
activation
Wires error Verifify to have 12V beetween TRGP and TRGN
when alarm is ON.
Empty bag- replace it following instructions on
Paragraph 13
Mains power overload Try a complete power down (mains and battery)
to recover unit. With no results board needs to
be replaced
Electronic Board overheath Clean side air flow holes
Unit cannot be ARMED
BLU LED OFF
Wires error Verifify to have 12V beetween ARMP and ARMN
when alarm panel is active.

5 TECHNICAL SPECIFICATIONS
Weight without bag
Max fog emission in a single shot
Total fog emission capacity x bag
Fog bag capacity
Working time without mains power
Average power consumption during heating
Heating time
Average power consumption range
Maximum current consumption at 12 V
Batteries type suggested
Cover tamper
RTC real time clock
5
The “empty” signal does not mean only that the bag is empty,
but also warns that the system has shot at least 100 seconds (Modular 2 CPlus)
or 80 seconds (Modular 3 Cplus).Warning : press “RESET” button only when you
actually exchange the bag or you will lose the seconds counting.
WARNING :
- Do not disconnect the machine immediately after the shot
- Change the battery every two years
- Change the bag as soon as the “empty” signal appears
- The generator must have the side holes free for air ventilation
8 Kg
200 m3
750 ml
2 hours
170 W + 10
120 minutes
37- 41 W
1,2 A
Pb 2 Ah 12V
microswitch
Yes
800 m3
Pb 2 Ah 12V
MODULAR 2 PLUS
300 m3
Pb 2 Ah 12V
MODULAR 3 PLUS
400 m3
Pb 2 Ah 12V
MODULAR 4 PLUS
500 m3
Pb 2 Ah 12V
MODULAR 5 PLUS MODULAR 8 PLUS
9 Kg 10 Kg 10 Kg 11 Kg
1250 m31250 m31700 m31700 m31700 m3
750 ml 1000 ml 1000 ml 1000 ml
2 hours 2 hours 2 hours 2 hours
170 W + 10 280 W + 10 280 W + 10 280 W + 10
120 minutes 140 minutes 140 minutes 150 minutes
37 - 41 W 42 - 47 W 42 - 47 W 48 - 53 W
1,4 A 1,7 A 1,9 A 2,1 A
microswitch microswitch microswitch microswitch
Yes Yes Yes Yes
LAN & WIFI board support Yes Yes Yes Yes Yes
16
14 DEFECTS POSSIBLE SOLUTION
DEFECT FOUND POSSIBLE CAUSE POSSIBLE SOLUTION
Disturbance/ interference
or potential differences
between devices
In the evenience of high noise on mains power
(lightings) an error while reading thermocouple
values can occur. Execute a complete Power Down
(mains and battery) to recover unit. If even recovery
fails the unit may be faulty
In very large installations or with more than one fog
units connected to the same alarm panel , a mains
power difference can occur , in that evenience the
units have to be decoupled
Error in the thermal loop Error on thermocouple, resistor. Please refer to
technical service
All products are 100% tested
before shipping and a small
ammount of liquid could be
still in the warming unit
This condition is normal and can happen on first
installation, it will completely disappear in a while
when the unit will become completely hot.
Small fog flow coming out from
nozzle
RED Led ON (Error)
Too low battery level or exaust Replace Battery
Bag in Reserve or Empty Replace fluid Bag
No Mains power check mains power or F5 fuse
RED Led ON(Fault)
Heater Temperature too high or
thermocouple error
Switch off the unit and verify the screw on TC2
connector
Poor ventilation Switch off the unit and clean air holes

6
6 HOW TO ACTIVATE THE SYSTEM
To avoid injuries please securely fix the fogging machine to the wall according to the installation instructions.
It is suggested not to install the machine behind walls in a limited closed area without a specific ventilation, in order to prevent a
possible overheating.
CAUTION: It is always recommended to fix the fog generator to a wall even when it is placed on a flat surface. The optional VESA
bracket, mainly recommended for ceiling installation, can also simplify standard installation, by allowing to use back holes for the
passage of cables. Always verify that the bracket or the support surface are suitable for the weight of the machine.
After removing the machine from the package, unscrew the 4 screws fixing the front panel and remove it.
15
13 MAINTENANCE
UR FOG fogging systems don’t need special maintance , nevertheless is suggested a periodical check to the following parts by skilled
operators :
1) Verify battery and power supply status.
2) Verify screws are firmly closed.
3) Verify the output nozzle is not damaged and without anyting inside.
4) Verify pneumatic circuit.
5) Verify once a year liquid pump.
BATTERY AND POWER SUPPLY CHECK
Verify that the output of the power supply without any load (battery unplugged ) is 14,1 V on the PSU and 13,8 V on FASTON battery
connectors.If a different value is noticed , set the trimmer on power supply.
Verify battery status (integrity check , no overheating);is suggested to replace the battery on 2 years base due to the heavy load during
shots without mains power.
SCREWS
Verify that all fixing screws are correctly setted and eventually rescrew them.
OUTPUT NOZZLE
Verify that output nozzle is not damaged and that there is nothing inside blocking the fog ejection flow.
YEARLY PUMP FUNCTIONALITY TEST
The test is done executing a trial shot on the unit.To avoid creating too much fog during the test is suggested to stop the flow after a few
seconds dearming the unit under test.The fog flow will immediatly stop.

- The battery is necessary to use the system in a safe way. The battery is
recharged by system board.
- The placing of the lead-acid battery 2 Ah DC 12 V is under the heat
exchanger, in flat position with poles facing the plastic cover.
- In order to accede to the battery case is necessary to remove the frontal
cover.
7
7 MAINS POWER AND POWER SUPPLY CONNECTIONS
Mains power (110V or 230V ) source supplies energy to the heating system and to the internal power supply. A DC 12v 2.0Ah battery
(not included ) must be connect to the recharge circuit to allow unit to shoot even without mains power. The heating element is of 180W,
at the heating startup the power consumption is about 170W and in some minutes it goes down. The average consumption range is from
around 37 W (Modular 2) to 53 W (Modular 8). Ambient temperature and battery loading can influence the average power consumption.
Do not use inverter or UPS if you are not sure that they generate a true sine wave, not a rebuilt one. Please refer to the UPS
manufacturer the correspondance of such features before proceeding with the connection.
-The max current to be considered for the system is 3,15A
-The connection to the electricity grid (110v or 230V ) must be performed by a qualified technician.
-Connect the equipment to the electricity grid only after you have completed the installation.
- It is necessary to connect the ground terminal.
- The system must be connected to the mains trough on automatic switch (automatic switch, curie C, with Ih= 10 A and Idif= 30 mA,...)
with breching capacity based on the assumed fault current of the fogging system in the sampling point.
PLEASE NOTE THAT, AS ALL POWERED EQUIPMENT FROM THE ELECTRICITY GRID REQUIRING INSTALLATION,
IT IS SUBJECT TO COMPLIANCE WITH RULES OF THE COUNTRY IN WHICH IT IS INSTALLED
For section and types of wires, fuses, suitability of materials to installation sites etc..
REPLACE FUSE ONLY USING SAME TYPE ,FOLLOWING THOSE SPECIFICATIONS:
CERAMIC BODY FILLED WITH QUARTZ, REF. STD. EN60127-2-3/DIN41660 3,15Ah (EXAMPLE OMEGA GT520231)
1- Power supply main connections
2- Mains power
3- Ground connection
4- Battery holder (battery not included)
1
2
3
4
4
14
12 FRONT LEDS MEANING
RED LED (right)
ON: Error (Empty bag or low fluid , Mains power off/Battery low) or Fault
OFF : No error condition
BLU LED (center)
ON: Unit is armed and ready to shoot (with green led ON).
OFF: Unit is disarmed , shot not possible.
GREEN LED (left)
ON: Unit has reached the correct temperature
OFF: Unit in warming condition, no shot possible.
The top right RED led light (DL1) means unit is powered on. The RED FAULT led (DL7)
is located in the middle of the board.
EMPTY BAG
ARMED AND
READY
WARMING

8
8 DESCRIPTION OF INPUT AND OUTPUT CONNECTIONS
While connecting the machine to the mains power, it is raccomended to never disconnect existing ground cable.
The fact of disconnecting or modifing existing cables voids the warranty and can cause troubles or accidents
related to the temperature control.
Discrete signals port
The discrete signal port is hosted on a multiple way screwed connec-
tor, visible on the right side of Fig. 1.
In Tab. 1 is indicated the pinout, along with some important notes
about each signal.
IMPORTANT: the descriptions in Tab. 1 are valid if DIP-SWITCH 4 is
on OFF position (passive security, relays are normally NOT active).
The signals present on this port will always be available to the user
and will work in parallel with the commands received by the serial
interface. In no case a voltage greater than the board’s power supply
should be applied to any pin of this port, except for relay outputs that
can manage up to 60V, 500mA. Some interface options depend on
S3 (Dip Switch) conguration and W1 and W2 jumpers: Fig.2 shows
their position on the board.
FUNCTION
DIP
SWITCH
g 1
Tab. 1 13
11 INSTALLATION, EXCHANGE AND BAG RESET
N.B. When you close the cover, the buzzer will make a sound to confirm the tamper is closed.
Attention: Before opening the cover, make sure that the alarm control panel is in “service”
mode, so that the opening of the “anti-sabotage or tamper” circuit does not cause any alarm.
After that, insert a new bag until you hear the “click” of the metal plug (pictures at page 17) entering in its housing, then close the door.
Insert the plastic bag in the compartment as shown in
the picture
metal plug

9
10 CONNECTION EXAMPLES Label Direction Description
Modular Plus family fogging systems are designed to be simply connected to any existing Alarm Panel available on the
market.
In compliance to the existing rules and for security purpouse the activation of the fog emission should be as a result
of a “double conrmation” input.The meaning of the “ARM” signal is to be intended as a 1st conrmation.If a TRIG
command or a PIR validation input (if active) is received by the unit in “ARM” status (Blue led on), the unit will generate
fog for the time previusly dened and stored in the unit with the time setting procedure.
The unit is able to handle both activation procedure commonly available on fogging systems.
A) Siren emulation:
1)ARMING: when the alarm system is activated (local monitoring with sensors and active zones) a continuous signal
of rst consent must be sent to the unit (12v DC + to the ARMP PIN and 12v DC - to the ARMN PIN). The Blue LED on
the unit lights up to signal the armament status
2)SHOOTING: In case of activation of the alarm system for an event signaled by an area or sensor, the alarm panenl
must send a impulse signal (duration >500ms) to the unit (12v DC + to the PIN TRGP and 12v DC - to the PIN TRGN).
The device activates instantaneously and emits fog for the previously set time.
B) Relay activation:
1)ARMING: Dene on the alarm panel an area dedicated to the arming of the fog device. The relay in this area (NO)
will have to close when the alarm system is activated.
2)SHOOTING: Dene on the alarm panel an area dedicated to allow the emission of fog by the unit. The relay in this
area (NO) will have to close when the alarm system is activated by an event detected by an area or sensor.
Please note that is ARM costant signal is removed during the shooting, the units immediatly stops fog emission.
Optional shooting methods.
There are also some other activation methods on Modular Plus series , some of them depending also from other
optional devices, that let the installer able to satisfy the most common customer’s requests.
A) Additional TRIG button
The input IN0P/IN0N is an optional trig command device that can be added to command the fog emission.It acts
exactly as TRGP/TRGN input and follows the same rules.
B) Antirobbery TRIG button
The input IN1P/IN1N is an optional trig command that enables the device to create fog EVEN WITHOUT BEING AR-
MED.This option must be used only by a skilled about use and prescriptions person.To prevent accidental activation
this function must be activated by the installer only , that take the responsability to train users how and when use this
option.To activate antirobbery functions , move SW5 to ON position , turn off and back on the unit.
C)Cloud Monitoring/Activation by remote
The Modular Plus Series can be equipped with the URF0g ActiveCloud LAN board , that allows Ethernet (RJ45 or WiFi)
connectivity to full monitor , diagnostic and be interactive with the unit by remote.Please refer to you local URFog
dealer for more details
D)DUAL TECHNOLOGY PIR INPUT
A local PIR sensor can be installed near the device and directly connect to the Modular Plus board to activate the trig
only if presence is detected in the shooting area.This function is activated by closing the W1 (PIR INPUT ACTIVE) and
works in AND with the normal TRIG input received from the alarm panel.By closing ALSO W2 Jumper the PIR INPUT
conrmation will let the PIR work as standalone activation device.Turn off and back on the unit after Jumper setting.
12

10 11
Do not obstruct the nozzle when the generator is armed and bag is in.
The value in the first column indicates the volume of the room to be protected, with respective seconds of emission reported in the
second column. The value in m³ varies depending on the density to be obtained. With the suggested value it is possible to get the ma-
ximum density recommended to ensure the absence of any residual. In places where a little residual causes no problems, it is possible
to increase the shooting time. Please note that the more fog released, the more the time required to recover visibility. High levels of fog,
over recommended limits, can leave residual. Any residue usually goes away by itself within 24/48 hours, otherwise, being soluble in
water, it is enough to use a wet cloth for cleaning. If you desire to obtain an average of 1 meter visibility after 60 seconds, as specified
by the standard EN 50131-8 : 2019, as used as reference by all manufacturers of Fog generators, the number of shooting seconds it
is to be reduced in half.
SHOOTING TABLE MODULAR 4 PLUS (max 46 sec.)
SHOOTING TABLE MODULAR 5 PLUS (max 48 sec.)
SHOOTING TABLE MODULAR 8 PLUS (max 69 sec.)
m³ to protect Seconds of emission m³ to protect Seconds of emission m³ to protect Seconds of emission
50 (150*) 6 150 (450*) 21 300 (900*) 40
75 (225*) 9 200 (600*) 23 400 (1200*) 46
100 (300*) 12 250 (750*) 35
m³ to protect Seconds of emission m³ to protect Seconds of emission m³ to protect Seconds of emission
50 (150*) 6 150 (450*) 16 300 (900*) 27
75 (225*) 9 200 (600) 21 400 (1200*) 37
100 (300*) 12 250 (750*) 24 500 (1500*) 48
m³ to protect Seconds of emission m³ to protect Seconds of emission m³ to protect Seconds of emission
50 (150*) 5 200 (600*) 19 500 (1500*) 43
75 (225*) 8 250 (750*) 22 600 (1800*) 51
100 (300*) 10 300 (900*) 26 700 (2100*) 60
150 (450*) 14 400 (1200*) 35 800 (2400*) 69
*Industrial standard as from other manufacturers
SHOOTING TABLE MODULAR 2 PLUS (max 28 sec.)
m³ to protect Seconds of emission m³ to protect Seconds of emission m³ to protect Seconds of emission
50 (150*) 7 100 (300*) 14 200 (600*) 28
75 (225*) 9 150 (450*) 21
SHOOTING TABLE MODULAR 3 PLUS (max 40 sec.)
m³ to protect Seconds of emission m³ to protect Seconds of emission m³ to protect Seconds of emission
50 (150*) 7 150 (450*) 21 300 (900*) 40
75 (225*) 9 200 (600*) 28
100 (300*) 14 250 (750*) 35
RECOMMENDED SHOOTING SECONDS ACCORDING TO THE VOLUME SPACE TO PROTECT (m3)
Fogging systems Modular CPlus are able to produce fog continuously till the maximum time allowed , according to the model
specifications. There might be cases in which, due to specific characteristic of the location, levels of air temperature and pressure,
degree of the fog density and light in the target area, that the shooting time can be increased or decreased. For example, above
5 m of height the shooting time must be 20% more and above 7 m , every additional meter should be consideredas double.
(HxLxP) x D x V x R x I
HxLxP--------Height x Width x Depth of the area to protect
D-------------Density of the produced fog
V-------------Temperature and air pressure
R-------------Acceptable residue in case of saturation of V parameter
I--------------Intensity of the surface light
The following tables indicate the suggested fog emission in relation to the number of seconds of shooting set in average condition of
temperature, air pressure and humidity.
9 SHOOTING TIME SETTING
To set the shooting time, after removing the plastic front cover , in the middle of PCB is located the FIRETIME (S2) button.Holding down
the button , the 3 coloured front leds will flash and a sound is signal is executed by the buzzer , each flash/beep is equivalent to one
second of fog emission of the device.
Pressing the button again, the shooting time is not added to the one previously set, but will restart from zero.
If the button is pressed for a time higher of the unit capabilities , the fog emission will be set to the maximum allowed for the unit.
N.B. Before opening the cover ensure that the control panel is set to “service”, so that the opening of “anti-sabotage or
tamper” circuit does not cause any shooting.
N.B. Shooting time can be set according to whished seconds, but to correclty activate the bag reserve in full security, it
must be set to a minimun 4 seconds of shooting.
N.B. To correctly dimension the machines it is needed to verify that the saturation of the area occurs in faster time than the one
supposed for the theft.
Table of contents
Popular Control Unit manuals by other brands

CKD
CKD QEV2 instruction manual

Tyco
Tyco Star Hydrus S30 manual

Interspace Industries
Interspace Industries MasterCue V5 USB user manual

Valve Concepts
Valve Concepts 3200 Installation, operation and maintenance manual

Goetze
Goetze 810/410 Assembly and maintenance instructions

Marmitek
Marmitek AMM32 user manual