INTRODUCTION
The VE8001A/VE8001AR Networked Page Zone
Extender enables voice access to a single zone of
one-way paging over an IP-based LAN/WAN. This
allows page zone extension anywhere on the
network. The VE8001A is designed for wall or table
placement. The VE8001AR is designed for 19”
mounting (1U).
SPECIFICATIONS
Features
1 Audio Input
2 Audio Outputs
2 Form C Relays
1 Contact Closure Input
RJ-45 jack for network connection
Front panel activity LED
Provides audio for up to 40 Valcom one-way
amplified speaker assemblies
AUX audio input via RCA jack
Contact closure or VOX operation of audio input
Removable screw terminal connectors provided
for audio and relay interface
AUX input music mutes during page
Output control contact closure provided during
paging output
Compatible with 25 or 70 Volt amplifiers
Barrel jack for optional DC power
Power over Ethernet 802.3af Compatible
Dimensions/Weight (VE8001A)
1.38 H x 6.13" W x 5.25" D
(3.50cm H x 15.6cm W x 13.33cm D)
Weight: 1.25 lbs. (0.57 kg)
Dimensions/Weight (VE8001AR)
1 Standard 19” Rack Unit
1.75” H x 16.50” W x 5.25” D
(4.45 cm x 41.91 cm x 13.33 cm)
Weight: 5.10 lbs. (2.32 kg)
VE8001A
VE8001AR
Nominal Specifications
Input Impedance: 600 Ohms
Input Level: -10dBm nominal
Voice Switch Sensitivity: -21dBm
Music Source Input Impedance: 8 to 600 Ohms
Music Input Level: -10dBm nominal
Output Impedance: 50 Ohms
Output Level: - 10dBm nominal
Relay Current: 1 Amp @ 24VDC
Nominal Power Requirements
Via rear panel barrel connector:
Voltage: 24VDC
Current: 325mA
Via 802.3af PoE Ethernet Switch:
802.3af: Class 3
Environment
Temperature: 0 to +40° C
Humidity: 0 to 85% non-precipitating
Packing List
Qty
Item
1
VE8001A or VE8001AR
1
VSP Document
2
Mounting Brackets
4
Rubber Pads (VE8001A only)
6
Wood Screws (VE8001A only)

2947825
CAUTION: To reduce the risk of electric shock,
Do not remove cover.
No user serviceable parts inside.
Refer servicing to qualified service personnel.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
This symbol indicates that dangerous
voltage constituting a risk of electric
shock is present within this unit.
This symbol indicates that there are
important operating and maintenance
instructions in the literature accompanying
this unit.
INSTALLATION
NOTE: The telephone system referred to in this
manual is the customer premise equipment
such as an electronic key system, a PBX or a
dedicated single line telephone sets. The
VE8001A/VE8001AR is not intended for direct or
indirect connection to the public telephone
network. When used with a customer premise
telephone system such as a key system or PBX
system, these units are interfaced to the system
via a fully protected page port or system central
office port, which is a fully protected interface
device. Also, the host system must be
configured to disallow central office trunk
conferencing in order to prevent indirect
connection to the public network.
Precautionary Designations
FCC Information
This equipment has been tested and found to
comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference when
the equipment is operated in a commercial
environment. This equipment generates, uses
and can radiate radio frequency energy and if
not installed and used in accordance with the
instruction manual, may cause harmful
interference to radio communications.
Operation of this equipment in a residential area
may cause harmful interference in which case
the user will be required to correct the
interference at his own expense.
Mounting
The VE8001A is designed for wall or table
mounting. The VE8001AR is designed for 19” rack
mounting (1U).
Table: Provided with the VE8001A are four rubber
pads. Peel these pads off their carrier backing and
place at the four corners of the bottom of the unit.
Wall: Secure mounting brackets to the VE8001A,
then secure the VE8001A to the wall. See Figure 1.
Rack: Secure mounting brackets to the VE8001AR.
See Figure 1. Place the VE8001AR into a standard
19” rack and secure to rack with proper hardware
(not included).
Figure 1.
Power Connections
The preferred method of powering a
VE8001A/VE8001AR is via a Power over Ethernet
(PoE) switch meeting the 802.3af specification.
If the rear panel barrel connector is used for power,
the preferred power supply is a Valcom VIP-324D.
Make all required signal connections before
applying power to the unit. If powering via 802.3af,
make sure all signal connections via the back panel
are made then connect the VE8001A/VE8001AR to
the Ethernet switch.
If power is supplied via the barrel connector, make
sure all signal connections are secure. Attach the
unit to the network via the front panel RJ-45
Ethernet connector. Apply power by plugging the
power supply into the VE8001A/VE8001AR via the
barrel connector on the rear of the
VE8001A/VE8001AR.

3947825
AUX
IN
INPUTS
AUDIO CC PAGE
1234
+24V DC
K1 K2
NO
COM
NC
NC
COM
NO
AUX
OUTPUTS
ON
Network Connection
The VE8001A/VE8001AR has one RJ-45 network
connector on the front panel. Use a standard
Ethernet patch cable to connect the
VE8001A/VE8001AR to an Ethernet switch.
Rear View
Signal Connections
The VE8001A/VE8001AR has signal connectors on
the rear panel:
RCA jack for AUX audio input
2 Audio outputs
2 Form C relays
1 Audio input
1 Contact Closure input
AUX Input: Local audio may be input via the
rear panel RCA jack. Nominal input impedance
is 600 Ohms. Connect any compatible audio
source using an RCA patch cable. Audio
supplied through the rear panel RCA jack is
transformer coupled to both Audio Out terminals
when paging is idle. This is typically used for
background music.
Audio Out: Two audio output connections are
provided. The terminals labeled “Page” provide a
signal output compatible with Valcom self-amplified
speakers. Up to 40 Valcom speakers can be
connected to the Page output. The terminals
labeled “AUX” provide a signal output compatible
with most amplifiers and should be used where a
transformer-coupled output is desired.
DIP Switch: The four-pole DIP switch controls a
supervision signal on the “Page” audio output line.
For systems where supervision is used, setting DIP
switches 1 & 2 to ON enables supervision on the
Page audio output connections. Where supervision
is not used, set DIP switches 1 & 2 to OFF.
Switches 3 & 4 are not used.
Audio Input/Contact Closure: One Audio Input
and one Contact Closure input are provided.
Neither input is polarity sensitive. The contact
closure is labeled "CC". The audio input
terminals are labeled "AUDIO".
Relay Channels: Access to the two form C relays
is provided via a six pin screw terminal block. The
relays are labeled K1 and K2. Each relay is
brought out on three terminals. The common
contact is the middle terminal with the normally
closed contact on the right and the normally open
contact on the left. Relay contacts are rated for 1A
@ 24VDC.
Status Indicator Lights
The VE8001A/VE8001AR has 3 status indication
lights on the front panel:
STATUS: Flashes during normal operation and
solid during system startup.
Green LED: (Link) Indicates Ethernet connection
when illuminated.
Yellow LED: (Activity) Indicator flashes to indicate
network activity.
SETUP
Information specific to your application will need to
be programmed into the VE8001A/VE8001AR using
a computer. The PC used for programming should
be connected to the same subnet as the
VE8001A/VE8001AR. Setup will be done using the
IP Solutions Setup Tool. Download the latest
version of the free IP Solutions Setup Tool from the
Valcom web site at www.valcom.com/vipsetuptool.

4947825
TECHNICAL ASSISTANCE
When trouble is reported, verify power is being
supplied to the unit and there are no broken
connections. If a spare unit is available, substitute
a spare unit for the suspected defective unit.
Assistance in troubleshooting is available from the
factory. Call (877) 427-2166 and ask for
Valcom Engineered Solutions Technical Support, or
visit our website at www.ValcomES.com.
Valcom equipment is not field repairable.
Valcom, Inc. maintains service facilities in Roanoke,
VA. Should repairs be necessary, attach a tag to
the unit clearly stating your company name,
address, phone number, contact person and the
nature of the problem. Send the unit to:
Valcom, Inc.
Repair & Return Dept.
5614 Hollins Road
Roanoke, Va. 24019-5056
VALCOM LIMITED WARRANTY
Valcom, Inc. warrants its products only to the original purchaser, for its own use, to be free from defects in materials and workmanship under conditions of
normal use and service for a period of one year from the date of shipment. This Limited Warranty obligation shall be limited to the replacement, repair or refund
of any such defective device within the warranty period, provided that:
1. inspection by Valcom, Inc. indicates the validity of the claim;
2. the defect is not the result of damage, misuse or negligence after the original shipment;
3. the product has not been altered in any way or repaired by others and that factory sealed units are unopened (a service charge plus parts
and labor will be applied to units defaced or physically damaged);
4. freight charges for the return of products to Valcom are prepaid;
5. all units 'out of warranty' are subject to a service charge. The service charge will cover minor repairs (major repairs will be subject to
additional charges for parts and labor).
This Limited Warranty is in lieu of and excludes all other warranties, expressed or implied and in no event shall Valcom, Inc. be liable for any
anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection with the purchase, operation,
maintenance, installation, removal or use of the product. The maximum liability of Valcom under this warranty is limited to the purchase price of the
specific Product covered by the warranty.
Disclaimer. Except for the Limited Warranty provided herein, the product is provided “as-is” without any warranty of any kind whatsoever including, without
limitation, any WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT.
This warranty specifically excludes damage incurred in shipment. In the event a product is received in damaged condition, the carrier should be notified
immediately. Claims for such damage should be filed with the carrier involved in accordance with the F.O.B. point.
Headquarters:
Valcom, Inc.
5614 Hollins Road Roanoke, VA 24019-5056
Phone: (540) 563-2000 FAX: (540) 362-9800
This manual suits for next models
1
Other Valcom Extender manuals

Valcom
Valcom Class Connection VE8004 User manual

Valcom
Valcom VIP-804A User manual

Valcom
Valcom IP Solutions VIP-802 User manual

Valcom
Valcom VIP-804 User manual

Valcom
Valcom VIP-801-IC User manual

Valcom
Valcom VE5090AL User manual

Valcom
Valcom V-1095 User manual

Valcom
Valcom VE8004A User manual

Valcom
Valcom IP Solutions VIP-800 User manual

Valcom
Valcom V-1095A User manual