GENERAL
The V-136RT is a single-path dial select
microprocessor controlled intercom and page control
unit used with a 1A2 key system to provide 36 zones
of bell or buzzer signalling.
The V-136RT control unit has received an FCC type
KX registration; designed to be used with FCC
registered key telephone systems. In accordance with
FCC rules with applicable tariffs, this paging unit
may only be installed with the authorization of the
host system. Installations may be made by Valcom,
Inc., an authorized agent of the same, equipment
manufacturers, telephone companies, registered
telephone refurbishers, and those qualified for
installation of FCC registered systems under FCC
Rules Section 68.215. The FCC Registration
Number, BAF9I7-69366-KX-N, will be listed in the
affidavits filed with the telephone company; it will be
also be recorded in the system log kept by installation
and maintenance personnel. The local telephone
company is to be notified when this intercom unit is
installed.
SPECIFICATIONS
Features
•Dial tone
•Ringback tone
•Last number dialed rering
•Conference call (tone only)
•Combined rotary or tone dialing
•Dial/ringback tone mute
•Mixed bell and buzzer operation
•Single or double burst signaling
Numbering Plan
•The dialing codes are 0, 5 - 39
Dimensions/Weight
•7.1"H x 5.9"W x 2.1"D
(18.03cm x 14.99cm x 5.33cm)
•3.25 lbs. (1.47 kg)
Power Requirements
Voltage Working Limits Current
Talk Battery -21.5 to –26 Vdc 90mA
Signal Battery -21.5 to –26 Vdc 350mA
Electrical Characteristics
Parameter Working Limits
Input Imp. T and R 600 ohm (incl. inst.)
Signal Contacts 1.5 amps
Signal Time 1 second
Dial Pulses 8-12 PPS
60-40 Break ratio +/- 10%
Tone Frequencies Industry Standard
Frequency
Bandwidth 3%
Twist 6db
Detect 40MS
Interdigital Time 40MS
Environmental
Temperature 0oto 50o
Humidity 0 to 85%
Non-precipitating

2947136
INSTALLATION
Precautions
All precautions have been taken at the factory to
insure that the equipment functions properly when
installed correctly. Please observe the following
precautions before applying power to the equipment
or the equipment may be damaged and the warranty
voided.
•Unplug the power supply before making any
connections to the control unit.
•Do not locate the control unit closer than 18
inches or further than 5 feet from the power
supply.
•Do not use a lamp tester to check signals, use a
voltmeter. A lamp tester when first applied is a
short circuit to electronic circuits.
•Do not apply power to the control unit until all
connections have been double-checked.
Mounting
Mount the V-136RT on a 7" KTU mounting, relay
rack or on the wall.
Connections
•Fasten a 25 pair cable to the unit and terminate
all leads on a 66 type block per Figure 1, 2 or 3.
•Strap 1 ground, B ground, lamp ground, 18 Vac
and 105 Vac signal grounds common at power
supply.
•Refer to Figure 1 for connections; use the chart
in Figure 1 to set the option programming.
NOTE: Option switches 3 and 4 must be in the off
position for proper operation with bells or
buzzers.
•Refer to Figure 2 for connections for 36 stations
of buzzer signalling. This figure may also be
used for 36 stations of bell signalling by
replacing the 18 Vac buzz voltage with 105
Vac ring voltage.
•Refer to Figure 3 for connections for mixed
signalling with 20 stations of bells and 16
stations of buzzers.
OPERATION
To make an intercom call, go off-hook and dial the
number of the desired station. Dial tone will be
broken after the first number is dialed. A one second
ringback tone will indicate that the called station is
being signalled.
To rering the same station, press the "*" button. The
station will be signalled as long as the * button is
held. To rering rotary, dial "1". The station will be
signalled for one second each time a "1" is dialed.
For conference calling (tone only), dial the first
station number, press the "#" button to receive dial
tone, then dial the next station number.
General Method of Operation
When the calling party goes off-hook, the switch
hook contacts in the telephone set close the tip and
ring to form a loop. Loop closure detection logic
then operates the lamps at all stations and returns dial
tone to the telephone set. Dial detection circuitry will
then receive dialing information and operate relays
and/or circuitry to supply signalling voltage to the
desired station.
TECHNICAL ASSISTANCE
When trouble is reported, verify that:
•All telephone sets are in proper working order
•Power is being supplied to the unit
•There are no broken connections at the
connecting block
•The conductors of color coded cables are
terminated in the proper order
If trouble still exists, additional checks should be
made using the following equipment:
•Voltmeter
•Tone-dial single-line instrument (for tone-dial
systems)
•Telephone Test Set
•Clip leads
Before proceeding further, check the voltages at the
connecting block. An undetected blown fuse or low
voltage will cause improper control operation. DC
voltage measurements are made with respect to (+)
ground.
If a spare unit is available, continue to troubleshoot
by substituting the spare unit for the suspected unit.
If the trouble has not been located, refer to the
Troubleshooting Chart. Identify the symptoms and
perform the corrective actions indicated. After all the
suggested tests have been performed, the trouble still
exists, call Valcom at (540) 427-3900 and ask for

3947136
Technical Support, or call (540) 427-6000 for
Valcom 24-hour Automated Support or visit our
website at http:www.valcom.com.
Valcom equipment is not field repairable. Valcom,
Inc. maintains service facilities in Roanoke, VA.
Should repairs be necessary, attach a tag to the unit
clearly stating company name, address, phone
number, contact person, and the nature of the
problem. Send the unit to:
Valcom, Inc.
Repair and Return Dept.
5614 Hollins Road
Roanoke, VA 24019-5056
TROUBLESHOOTING CHART
PROBLEM CORRECTIVE ACTION
No side tone.
No dial tone.
No lamps.
No audible signal at station dialed.
Double signaling.
Continuous signaling
Stations 10 through 29
Stations 30 through 39,
0, and 5 through 9
Check "A" battery connections, polarity. and voltage.
Check option switch 1. Check "B" battery connections, polarity, and
voltage.
Check lamp supply voltage and input. Verify that grounds are common
at power supply.
Check signal voltage at supply and frame locations. Verify bell and
buzzer returns are common at power supply.
Check option switch 2.
Check option switch 3.
Check option switch 4.
VALCOM LIMITED WARRANTY
Valcom, Inc. warrants its products to be free from defects in materials and workmanship under conditions of normal use and service
for a period of one year from the date of shipment. The obligation under this warrantyshall be limited to the replacement, repair or
refund of any such defective device within the warranty period, provided that:
1. inspection by Valcom, Inc. indicates the validityof the claim,
2. the defect is not the result of damage, misuse, or negligence after the original shipment.
3. the product has not been altered in any way or repaired by others and that factory sealed units are unopened (A service
charge plus parts and labor will be applied to units defaced or physically damaged),
4. freight charges for the return of products to Valcom are prepaid,
5. all units ‘out of warranty’ are subject to a service charge. The service charge will cover minor repairs (Major repairs will be
subject to additional charges for parts and labor).
This warranty is in lieu of and excludes all other warranties, expressed or implied, and in no event shall Valcom, Inc. be
liable for any anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection
with the purchase, operation, or use of the product.
This warrantyspecifically excludes damage incurred in shipment. In the event a product is received in damaged condition, the
carrier should be notified immediately. Claims for such damage should be filed with the carrier involved in accordance with the
F.O.B. point. Headquarters: In Canada

4947136
Valcom, Inc. CMX Corporation
1111 Industry Avenue 35 Van Kirk Drive #11 and 12
Roanoke, VA 24013 Brampton, Ontario L7A1A5
Phone: (540) 427-3900 Phone: (905) 456-1072
FAX: (540) 427-3517 FAX: (905) 456-2269

5947136
W/BL
BL/W
W/O
O/W
W/GR
GR/W
W/BR
BR/W
W/S
S/W
R/BL
BL/R
R/O
O/R
R/G
G/R
R/BR
BR/R
R/S
S/R
BK/BL
BL/BK
BK/O
O/BK
BK/G
G/BK
BK/BR
BR/BK
BK/S
S/BK
Y/BL
BL/Y
Y/O
O/Y
Y/G
G/Y
Y/BR
BR/Y
Y/S
S/Y
V/BL
BL/V
V/O
O/V
V/G
G/V
V/BR
BR/V
V/S
S/V
ABC DEF
T
R
LB
L
PC
S10
S11
S12
S13
S14
S15
S16
S17
S18
S19
S20
S21
S22
S23
S24
S25
S26
S27
S28
S29
S30
S31
S32
S33
S34
S35
S36
S37
S38
S39
S0
S5
S6
S7
S8
S9
S1 IN
S2 IN
AG
AB
BG
BB
R10
R11
R12
R13
R14
R15
R16
R17
R18
R19
R20
R21
R22
R23
R24
R25
R26
R27
R28
R29
R30
R31
R32
R33
R34
R35
R36
R37
R38
R39
R0
R5
R6
R7
R8
R9
CABLE FROM
CONTROL UNIT SPLIT BLOCK
66B350
BUZZER
OR
BELL
RETURN
ICM KEYS
POWER SUPPLY
ICM KEYS
PAGE CONTROL
AUDIBLE SIGNAL
POWER SUPPLY
NOTES:
1) BELL/BUZZER GROUP ONE:
STATIONS 10-29
2
) BELL/BUZZER GROUP TWO:
STATIONS 30-39, 0, 5-9
3) AUDIBLE SIGNAL: 18VAC
BUZZ OR 105VAC RING
4
) POWER SUPPLY: A BAT.
-24VDC FILTERED TALK
BATTERY. B BAT. -24 VDC
UNFILTERED BATTERY
SW
NO DIAL
TONE DIAL
TONE
1
2 DOUBLE SINGLE
BURST BURST
ON OFF
OPTIONS
3STA 10-
STA 29
BUZZER
STA 10-
STA 29
4 BUZZER
BELL:
STA 30-
39, 0,
5 - 9
1
2
3
4
OFF ON
FIGURE 1: CONNECTING BLOCK ARRANGEMENT V-136RT
5) AUDIBLE GND., LAMP GND.,
A GND. AND B GND. MUST
BE COMMON AT POWER
SUPPLY.
6) OPTION PROGRAMMING:
CONTINUOUS
CONTINUOUS
STA 30-
39, 0,
5 - 9
26
1
27
2
28
3
29
4
30
5
31
6
32
7
33
8
34
9
35
10
36
11
37
12
38
13
39
14
40
15
41
16
42
17
43
18
44
19
45
20
46
21
47
22
48
23
49
24
50
25
BUZZER
OR BELL
SIGNAL
GROUP
ONE
BUZZER
OR BELL
SIGNAL
GROUP
TWO
BELL

6947136
W/BL
BL/W
W/O
O/W
W/GR
GR/W
W/BR
BR/W
W/S
S/W
R/BL
BL/R
R/O
O/R
R/G
G/R
R/BR
BR/R
R/S
S/R
BK/BL
BL/BK
BK/O
O/BK
BK/G
G/BK
BK/BR
BR/BK
BK/S
S/BK
Y/BL
BL/Y
Y/O
O/Y
Y/G
G/Y
Y/BR
BR/Y
Y/S
S/Y
V/BL
BL/V
V/O
O/V
V/G
G/V
V/BR
BR/V
V/S
S/V
ABC DEF
T
R
LB
L
PC
S10
S11
S12
S13
S14
S15
S16
S17
S18
S19
S20
S21
S22
S23
S24
S25
S26
S27
S28
S29
S30
S31
S32
S33
S34
S35
S36
S37
S38
S39
S0
S5
S6
S7
S8
S9
S1 IN
S2 IN
AG
AB
BG
BB
R10
R11
R12
R13
R14
R15
R16
R17
R18
R19
R20
R21
R22
R23
R24
R25
R26
R27
R28
R29
R30
R31
R32
R33
R34
R35
R36
R37
R38
R39
R0
R5
R6
R7
R8
R9
CABLE FROM
CONTROL NIT
FIGURE 2: CONNECTIONS FOR 36 STATIONS OF BUZZER SIGNALLING
BRIDGE
STRAP
STRAP
LG
LB
T
R
LG
L
STRAP
AG
-24
AB
BG
-24
BB
POWER
S PPLY
TELEPHONE
SETS
M LTIPLE TO
ALL PHONES SPLIT BLOCK
66B350
B ZZER
AT EACH
STATION
18 VAC
B ZZ
B ZZ
GND
B ZZ
B ZZ
B ZZ

7947136
W/BL
BL/W
W/O
O/W
W/GR
GR/W
W/BR
BR/W
W/S
S/W
R/BL
BL/R
R/O
O/R
R/G
G/R
R/BR
BR/R
R/S
S/R
BK/BL
BL/BK
BK/O
O/BK
BK/G
G/BK
BK/BR
BR/BK
BK/S
S/BK
Y/BL
BL/Y
Y/O
O/Y
Y/G
G/Y
Y/BR
BR/Y
Y/S
S/Y
V/BL
BL/V
V/O
O/V
V/G
G/V
V/BR
BR/V
V/S
S/V
ABC DEF
T
R
LB
L
PC
S10
S11
S12
S13
S14
S15
S16
S17
S18
S19
S20
S21
S22
S23
S24
S25
S26
S27
S28
S29
S30
S31
S32
S33
S34
S35
S36
S37
S38
S39
S0
S5
S6
S7
S8
S9
S1 IN
S2 IN
AG
AB
BG
BB
R10
R11
R12
R13
R14
R15
R16
R17
R18
R19
R20
R21
R22
R23
R24
R25
R26
R27
R28
R29
R30
R31
R32
R33
R34
R35
R36
R37
R38
R39
R0
R5
R6
R7
R8
R9
CABLE FROM
CONTROL NIT
FIGURE 3: CONNECTIONS FOR SPLIT SIGNALLING WITH 20 BELL STATIONS
AND 16 BUZZ STATIONS
BRIDGE
STRAP
STRAP
LG
LB
T
R
LG
L
AG
-24
AB
BG
-24
BB
POWER
S PPLY
TELEPHONE
SETS
M LTIPLE TO
ALL PHONES SPLIT BLOCK
66B350
BELL
STATIONS
18 VAC
B ZZ
B ZZ
GND
B ZZ
BELL
BELL
BELL
B ZZ
B ZZER
STATIONS
105VAC
RING
RING
GND

8947136
BATTERY
FEED
TONE
GEN.
TONE
DECODER
AB
AG
MICRO-
PROCESSOR
MEMORY
&
DIAL
P LSE
DETECTOR
K1
K2
K11
POWER
S PPLY
BB
BG
LAMP S P.
K11
LAMP
STA 9
STA 8
STA 31
STA 30
STA 29
STA 28
STA 11
STA10
SIG IN 1
V-136RT SIMPLIFIED SCHEMATIC
PC SIG IN 2
K3
K4
K2
K7
K8
K7
K6
K2
K7
K5
K6
K7
K1
K8
K10
TIP
RING
K9
Table of contents
Other Valcom Intercom System manuals

Valcom
Valcom VIP-581A-IC User manual

Valcom
Valcom V-2901A User manual

Valcom
Valcom V-1074 User manual

Valcom
Valcom V-136RTHF User manual

Valcom
Valcom V-2928 User manual

Valcom
Valcom VIP-176 User manual

Valcom
Valcom V-2924A User manual

Valcom
Valcom V-2924 User manual

Valcom
Valcom VIP-160A-IC User manual

Valcom
Valcom VIP-9894-1 User manual

Valcom
Valcom V-2926 User manual

Valcom
Valcom VIP-172AL User manual

Valcom
Valcom VIP-148L User manual

Valcom
Valcom V-2900 User manual

Valcom
Valcom VIP-801A User manual

Valcom
Valcom V-2904 User manual

Valcom
Valcom VE9894-1-Finish User manual

Valcom
Valcom V-2924A User manual

Valcom
Valcom V-2900 User manual

Valcom
Valcom V-ACS25 User manual