TEMPTRAC - INSTRUCTIONS FOR USE
FCC ID: Z9F-TEMPSENSOR
IC : 11852A-TEMPSENSOR
SETUP GUIDE – TEMPTRAC
www.valortpms.com
2
1. INTRODUCTION OF TEMPTRAC
This Temptrac developed for refrigerated transport vehicles. It can send temperature data to
the data receiver in time, so that customers can monitor the temperature in the refrigerator. It
has the advantages of simple installation, high precision of temperature test and long service
life.Temptrac is a new temperature transmitter based on evaluation of transmitter in truck
series. It does not detect pressure data but only monitor temperature, which the temperature
accuracy is higher and working mode is easier than the truck series transmitter. In addition,
Temptrac inherits most of the functions of truck series transmitter, including RF data
transmission, frequency:433.92MHz;-20dbm≥transmitting power≥-60dbm;low-frequency
activation, factory test mode and so on.
www.valortpms.com
3
INSTALLATION GUIDE – TEMPTRAC
Truck Diagram
There Are 2 Installation Steps For This Product:
2. TRUCK CAB INSTALLATION
NOTE: The Transceiver needs to be installed near
the GO7 Unit.
1. Connect the supplied GO Wire Harness to the
Transceiver.
2. Connect the other end of the supplied Valor
Wire Harness to the Geotab IOX-CAN Harness.
3. The Geotab IOX-CAN Harness connects to the
GO7 device. Connect to the vehicle where indicated.
4. Data is communicated over the Geotab IOX-CAN.
5. Route the antenna to the rear of the cab and mount in a
safe place away from step and pinch points.
Each zone transmits separately:
 records ever 0.5 degree change
 records temperature when power is turned on
 records every 30 min when temperature is stable
 exceptions for temperature threshold are set by vehicle in
MyGeotab
The Geotab Report can chart temperature
data in either Celcius or Farrenheit.
My Geotab Reporting
Valor + Geotab Setup
3. REEFER UNIT INSTALLATION
NOTE: Turn on Sensors prior to installation (back of unit). Sensors are active
once turned on. In humid environments or where sensor can get wet
after turning on sensor, use dialectic silicon,or sealant on sensor power
switch.
6. There is a sensor for each zone and each sensor is assigned to a
zone. The sensor for zone one is marked
as such (Zone 1), while the sensor for zone two is unmarked.
Each sensor has a unique identifier code
which is pre-programmed into the Transceiver.
7. Install the sensors directly onto the Reefer Zones’
inside wall or ceiling using either the supplied velcro or
with screws (not supplied).
8. The sensors wirelessly transmit data to the Transceiver.
ZONE 1 ZONE 2
Antenna
Sensors
Geotab
GO Device
Transceiver
SETUP GUIDE – TEMPTRAC
www.valortpms.com
4
FCC Statement
This device complies with part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) this device may not cause harm ful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void
the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
‐ Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
‐Consult the dealer or an experienced radio/TV technician for help.
Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm between the radiator and
your body.
SETUP GUIDE – TEMPTRAC
www.valortpms.com
5
ISED Statement
‐ English: This device complies with Industry Canada license‐exempt RSS standard(s). Operation is
subject to the following two conditions: (1) This device may not cause interference, and (2) This device
must accept any interference, including interference that may cause undesired operation of the device.
The digital apparatus complies with Canadian CAN ICES‐3 (B)/NMB‐3(B).
‐ French: Le présentappareilestconforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitationestautorisée aux deux conditions suivantes: (1) l'appareil ne doit
pas produire de brouillage, et (2) l'utilisateur de l'appareildoit accepter tout
brouillageradioélectriquesubi, mêmesi le brouillageest susceptible d'encompromettre le fonctionnement.
Cet appareil numérique de la Classe B est conforme à la norme NMB-003 du Canada.
This radio transmitter (ISED certifi cation number: 11852A-TEMPSENSOR) has been approved by
Industry Canada to operate with theantenna types listed with the maximum permissible gain indicated.
Antenna types not included in this list, having a gain greater than the maximum gain indicated for that
type, are strictly prohibited for use with thisdevice.
Le présentémetteur radio (ISED certifi cation number: 11852A-TEMPSENSOR) aétéapprouvé par
Industrie Canada pour fonctionner avecles types d’antenneénumérés ci-dessous et ayant un gain
admissible maximal. Les types d’antenne non inclusdanscetteliste, etdont le gain estsupérieur au gain
maximal indiqué, sontstrictementinterdits pour l’exploitation de l’émetteur.
Radiation Exposure Statement
This equipment complies with Canada radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20cm between
the radiator & your body.
Déclaration d'exposition aux radiations
Cet équipement est conforme Canada limites d'exposition aux radiations dans un environnement non
contrôlé. Cet équipement doit être installé et utilisé à distance minimum de 20cm entre le radiateur et
votre corps.
Hereby, [Shanghai Baolong Automotive Corporation], declares that this [TEPM sensor-QY1026] is
in compliance with the essential requirements and other relevant provisions of Directive 2014/53/
EU.The full test of the EU declaration of conformity is available at the following internet address:
www.baolong.biz

Other Valor Measuring Instrument manuals

Valor EXTREME DUTY TPMS User manual

Valor

Valor EXTREME DUTY TPMS User manual

Valor 203 User manual

Valor

Valor 203 User manual

Valor EXTREME DUTY TPMS User manual

Valor

Valor EXTREME DUTY TPMS User manual

Valor TPMS GAUGE User manual

Valor

Valor TPMS GAUGE User manual

Popular Measuring Instrument manuals by other brands

KAM BLUE MOVER 500 SD FSCAN instruction manual

KAM

KAM BLUE MOVER 500 SD FSCAN instruction manual

Lovato DML1 manual

Lovato

Lovato DML1 manual

Niigata seiki BEVEL BOX instruction manual

Niigata seiki

Niigata seiki BEVEL BOX instruction manual

ETI ENA33LCD User and service manual

ETI

ETI ENA33LCD User and service manual

PCB Piezotronics 3741B1210G Installation and operating manual

PCB Piezotronics

PCB Piezotronics 3741B1210G Installation and operating manual

PCB Piezotronics IMI SENSORS 645B02 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS 645B02 Installation and operating manual

Reed Instruments HT-6510A instruction manual

Reed Instruments

Reed Instruments HT-6510A instruction manual

Iijima PACK MASTER RO-105S user guide

Iijima

Iijima PACK MASTER RO-105S user guide

Nuvoair Air Smart Spirometer user manual

Nuvoair

Nuvoair Air Smart Spirometer user manual

Young 32400 SERIAL INTERFACE instructions

Young

Young 32400 SERIAL INTERFACE instructions

Northern Design MultiCube950mV installation guide

Northern Design

Northern Design MultiCube950mV installation guide

Lafayette Instrument NICHOLAS MMT 01160 instruction manual

Lafayette Instrument

Lafayette Instrument NICHOLAS MMT 01160 instruction manual

Sierra InnovaSonic 210 Quick install guide

Sierra

Sierra InnovaSonic 210 Quick install guide

SEFRAM 9835 instruction manual

SEFRAM

SEFRAM 9835 instruction manual

Hilti PP10 operating instructions

Hilti

Hilti PP10 operating instructions

Brainstorm Electronics SR-15+ Operation manual

Brainstorm Electronics

Brainstorm Electronics SR-15+ Operation manual

Honeywell SLN 700 Quick start installation guide

Honeywell

Honeywell SLN 700 Quick start installation guide

Endress+Hauser Smartec CLD18 operating instructions

Endress+Hauser

Endress+Hauser Smartec CLD18 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.