OPERATION
MANUAL
1. Do
not
mix
different
refrigerants
together
in one tank, or
they
could
not
be
separated
or used.
2. Before recovering the
refrigerant
, the tank should achieve the vacuum level: - 75cmHg(-29.6psi),
which is for purging non
-condensable
gases. Each tank was full of nitrogen when it was
manufactured
in the factory,
thus
the
nitrogen
should
be
evacuated
before
the first use.
3. The
switch
should
be at "0"
Position
before
operation
.All the
valves
must
be
closed
, the
input
and
output fittings should be covered with protective caps when the unit is not in operation. The air moisture
is
harmful
to the
recovery
result
and will
shorten
the life span of the unit.
4. A filter
drier
should always be used and should be replaced frequently. And each type of
refrigerant
must have its own filter. For the sake of ensuring the normal operation of the unit, please use the
filter
spec
ified by
our
company
. High
quality
f
ilter
drier
will bring
high
quality
services.
5.
Special-caution
is
needed
when
recovering
from
burnt
system
, and two dry
filter
is
needed
.
6. The
unit
has an
Internal
High
Pressure
Shut-Off
switch.
If the
pressure
inside
the
system
is
above
rated shut-off pressure (see specification) , compressor will automatically shut off and the high pressure
alarm
light
will turn on. To
restart
the
compressor,
please
lower
the
internal
pressure
(Output
gauge
ind
icates
lower
than 30
bar/435
.1 PSI) ,
after
the
high
pressure
alarm
light
turn off, hit the
Reset
button
, then turn on the
power
to
restart
the
compressor.
When high pressure protection is initiated, please find out the cause and deal with it before restarting
the unit.
Cause
of High
Pressure
Protection
and
Trouble
Shooting
:
CD
The
input
valve
of the
refrigerant
tank
is
closed--open
the
valve
will
help
solve
the problem.
® The connecting hose between the recovery unit and refrigerant tank is
stuck--close
all the valves
and
replace
the
connecting
hose.
® The
temperature
of the
refrigerant
tank is too high, pressure is too
high--give
it some time to cool
down
and the
pressure
will come back to
normal.
7. This
unit
can be used
together
with a
float
level
sensor
.
Please
connect
the
recovery
unit
and the
tank
with the 80% O.F.P.
Cable.
If the
liquid
refrigerant
reaches
80%
capacity
of the
tank
the
recovery
unit
will
automatically
shut
off
and the Red
Alarm
Light
turns
on.
Before
restart
please
change
a
new
tank.
8.
Please
press "
0"
button when
start
or
stop
running
the machine.
The
"
0"
light
is on
when
compressor
works
.
3