Vanderbilt V44 Duo Instruction Manual

1 2 3
65
98
4
7
B0
A
1
8
5
3
2
6
Vanderbilt International (IRL) Ltd.
Codelock V44 Duo
Installation & User Manual

Book Contents
English ..........................................................3
Svenska.......................................................27
Deutsch .......................................................51
Francais.......................................................79
Dansk.........................................................107
Suomi ........................................................131
Norsk .........................................................155

V44 Duo Installation & User manual 3
ENG
English
Technical specications and availability subject to change without notice.
© Copyright Vanderbilt International (IRL) Ltd.
We reserve all rights in this document and in the subject thereof. By acceptance
of the document the recipient acknowledges these rights and undertakes not to
publish the document nor the subject thereof in full or in part, nor to make them
available to any third party without our prior express written authorization, nor to
use it for any purpose other than for which it was delivered to him.

4 V44 Duo Installation & User manual
ENG
Contents
What is V44 Duo? ....................................... 5
Duress or alert ............................................................................ 6
Zero opening............................................................................... 6
Unlock the door permanently.................................................... 6
Door bell ...................................................................................... 6
Power supply .............................................................................. 6
The keypad.................................................. 7
Wiring .......................................................... 8
Programming ............................................ 10
Buzzer and LEDs ...................................................................... 10
Choose password .....................................................................11
Change password......................................................................11
Programming commands ........................ 11
Program codes.......................................................................... 12
Erase codes............................................................................... 13
Change codes ........................................................................... 14
Set opening time....................................................................... 15
Background lighting on/off...................................................... 15
Buzzer on/off............................................................................. 16
Toggle function on/off.............................................................. 16
Duress or Alert.......................................................................... 17
Door monitoring on/off............................................................. 18
Set door held warning time...................................................... 19
Delay on/off ............................................................................... 20
Erase the memory..................................................................... 20
Using V44 Duo .......................................... 21
Entrance .................................................................................... 21
Unlock the door permanently.................................................. 21
Enter duress code .................................................................... 22
Technical data........................................... 23

V44 Duo Installation & User manual 5
ENG
What is V44 Duo?
V44 Duo is a compact code lock with two relay outputs.
This makes V44 Duo capable of controlling two doors – or
one door and an optional function, e.g. a light switch. Either
a four- or a six-digit code can be used to open connected
doors. All programming is done from the keypad.
Open two doors using one code
The advantage of using two relay outputs is that two func-
tions can be activated at the same time, using only one
code. For example, the code can open the lock and turn on
a light switch at the same time.
Another setup is to connect the code lock to two doors.
One code is programmed to operate both doors, while the
other only opens one of the doors.
If the code is programmed to open both doors, you can set
V44 Duo so that the other door does not open until the rst
door has been opened and closed (see the Delay section).
For each code, choose whether to activate both relay
outputs, only one or only the other.
Disable the codes whenever needed
V44 Duo offers the possibility to disable codes at certain
times. For example, the cleaning staff’s access to the build-
ing can be limited to certain hours, while tenants/staff can
have access to the door 24 hours a day.
By connecting two time clocks to V44 Duo, three different
time zones can be used to control the codes: one controlled
by time clock 1, one controlled by time clock 2 and one that
is valid 24 hours a day, i.e. no time control.

6 V44 Duo Installation & User manual
ENG
Duress or alert
V44 Duo is equipped with an output that can be activated
for one of the following reasons:
• A user enters a duress code
OR
• The door held warning time expires or the door is
forced open
Choose which alternative to use. Then connect e.g. a bur-
glar alarm or similar to the output.
Zero opening
To make entrance easier, e.g. during ofce hours, connect
an external contact. Then use the contact to activate or
deactivate zero opening, i.e. opening the door by pressing
the zero button on the keypad. Note that this is only applies
to relay output 1.
Unlock the door permanently
If the Toggle function is activated, the code can be used to
unlock the door. The door remains open until a valid code is
entered once again (see the Toggle on/off section).
Door bell
If needed, a door bell can be connected to V44 Duo. To ring
the bell, the visitor presses the button labelled with a bell on
the code lock’s keypad.
Power supply
Ensure that the power supply is stable and within the rated
voltage of the unit. Use an uninterrupted power supply
(UPS) to ensure a continuous function of the unit in the
event of power dips on the mains supply.

V44 Duo Installation & User manual 7
ENG
The keypad
1 2 3
65
98
4
7
B0
A
Red LED
For optional
use, e.g. to
indicate alarm
on.
Yellow LED
Indicates key-
presses.
Green LED.
Lit when the
door is un-
locked.
= A.
Acts as a door bell
button and starts the
sequence telling the
V44 Duo what to you
want to program. E.g.
A21 to program codes.
B.
Press B and enter
the 6-digit password
to programme the
V44 Duo. Press B
to leave the pro-
gramming mode.

8 V44 Duo Installation & User manual
ENG
Wiring
12-24V
1
2
3
4
5
6
SW1
7
8
9
10
11
12
24
23
22
21
20
19
18
17
16
15
14
13
LED
TAMPER
0V
1
2
”0”
LOCK 1
0V
EXIT 1
CONTACT 1
LOCK 2
0V
EXIT 2
CONTACT 2
1
2
3
4
5
6
7
8
9
11
10
10
8
9

V44 Duo Installation & User manual 9
ENG
1
Power in, terminal nos 1(+) and 2. 12-24 V. **)
2
Input for extra LED (red), terminal nos 3 and 4. 10-35
V DC. **)
3
Tamper switch, terminal nos 5 and 6. Closed when
the housing is closed. **)
4
Code disabling from external time clock. *)
Input 1: Close terminal nos 8 and 7.
Input 2: Close terminal nos 9 and 7.
5
Output for alert or duress. Use E7 relay. Connect
between terminal nos 10 and 1(+). **)
6
Contact for zero (0) opening. Close terminal nos 11
and 7. *)
7
Output for Door bell (buzzer). Use E7 relay. Connect
between terminal nos 12 and 1(+). *)
8
Input for door contacts. The contact is closed when
the door is closed. Terminal nos 13 and 15 (19 and
21 respectively). *)
9
Exit button. The door opens on closing terminal nos
14 and 15 (20 and 21 respectively). *)
10
Electric locking device. Dashed line refers to locks
with fail-safe function. **)
11
SW1 push button. Used when choosing password
and erasing memory.
*) Cable < 3 m
**) Cable < 30 m

10 V44 Duo Installation & User manual
ENG
Programming
Before you start programming V44 Duo, make a note of the
codes to be used, to what timing group they should belong
and which relay output they should control. At the back of
this manual you will nd a chart designed for this purpose.
Look at the chart as you program V44 according to the
instructions below.
Buzzer and LEDs
During programming you will be guided by the buzzer and
the LEDs.
In programming mode before a function is chosen:
Green and yellow LED ashes.
During programming: Yellow LED goes out. Green LED
is lit.
Correct instruction: Conrmed by a rising signal consisting
of two quick beeps.
Faulty instruction: Conrmed by a falling signal consisting
of two quick beeps.
NOTE! During programming mode, if a button is not
pressed within 20 seconds, the code lock goes back
to normal operation.

V44 Duo Installation & User manual 11
ENG
Choose password
The rst thing to do before you can start programming is to
choose a password.
1 Press and hold the SW1 button on the code lock’s
circuit board. Both LEDs are lit.
2 Enter a 6-digit password.
3 Make a note of the new password in the chart at the
back of the manual.
Change password
1 Press B and enter the current password.
2 Enter A27.
3 Enter the new password. A warning tone is heard.
4 Enter the new password once again.
5 Press B to leave programming mode.
6 Make a note of the new password in the chart at the
back of the manual.
Programming commands
Always press B and the password before any commands
are used.
Leaving the programming mode can be done by pressing B.

12 V44 Duo Installation & User manual
ENG
Program codes
1 Press B and enter the current password.
2 Enter A21.
3 Enter the desired code location using two digits (01-
30).
4 Enter the code for the current code location (four digits
for code location 01-20 or six digits for code location
21-30).
Note! The four rst digits in a 6-digit code must not be
the same as the digits in a 4-digit code and the other
way around.
5 Choose whether or not the code should be disabled
from a time clock.
0 = no time control
1 = code disabled from time clock 1
2 = code disabled from time clock 2
6 Choose which relay output to control.
0 = both relay outputs
1 = relay output 1
2 = relay output 2
7 Program the next code by continuing from step 3 or
press B to exit.

V44 Duo Installation & User manual 13
ENG
Erase codes
1 Press B and enter the current password.
2 Enter A22.
3 Enter the current code. If it is a 4-digit code, enter A
after the last digit.
If it is a 4-digit code, enter 0000. If it is a 6-digit code,
enter 000000.
4 Enter 0000 (000000) again.
5 Enter 0.
6 Enter 0 once again.
7 Erase the next code by continuing from step 3 or press
B to exit.

14 V44 Duo Installation & User manual
ENG
Change codes
1 Press B and enter the current password.
2 Enter A22.
3 Enter the current code. If it is a 4-digit code, enter A
after the last digit.
4 Enter the new code using four or six digits.
5 Enter the new code once again.
6 Choose whether or not the code should be disabled
from a time clock.
0 = no time control
1 = code disabled from time clock 1
2 = code disabled from time clock 2
7 Choose which relay output to control.
0 = both relay outputs
1 = relay output 1
2 = relay output 2
8 Change the next code by continuing from step 3 or
press B to leave code program

V44 Duo Installation & User manual 15
ENG
Set opening time
The opening time determines for how long the lock should
remain open following a correct entrance code. When V44
Duo is delivered the opening time is 7 seconds for both
relays.
1 Press B and enter the current password.
2 Enter A28.
3 Enter the desired opening time (01-99) using two digits,
e.g. 09 for 9 seconds.
4 Choose which relay output the new opening time ap-
plies to:
0 = both
1 = relay output 1
2 = relay output 2
Background lighting on/off
This is how to turn off the keypad’s background lighting, if
needed.
1 Press B and enter the current password
2 Enter A60.
3 Enter 0.
To reactivate background lighting, press 1 in step 3 instead.

16 V44 Duo Installation & User manual
ENG
Buzzer on/off
This is how to deactivate the buzzer if sound on keypresses
and door opening is not desired. Note that the buzzer will
keep sounding during programming.
1 Press B and enter the current password.
2 Enter A65.
3 Enter 0.
To reactivate the buzzer, press 1 in step 3 instead.
Toggle function on/off
To be able to unlock a door permanently, the toggle function
has to be activated.
Proceed as follows:
1 Press B and enter the current password
2 Enter A81.
3 Enter 1.
4 Choose what relay outputs the toggle function should
apply to.
0 = both
1 = relay output 1
2 = relay output 2
To deactivate the toggle function, follow the above steps,
only enter 0 in step 3 instead.
In the Unlock the door permanently section you will nd
instructions on how to unlock the door permanently.

V44 Duo Installation & User manual 17
ENG
Duress or Alert
The V44 Duo allows for either using duress or alert. The
same command is used for different function.
Duress
With the Duress function activated, a user can enter a
special code if he or she is forced to open the door under
threat. It is important to have a plan for what action to take
when a duress code is entered.
NOTE! If Duress is activated, make sure you have not
programmed codes with consecutive digits. Code
1234 must not exist with codes 1235 and 1233.
Code 5679 must not exist with codes 5670 and
5678.
The Enter duress code section describes how a user should
enter the duress code.
Alert
When V44 Duo is delivered, the alarm output is set to be
activated if the door is open too long or if the door is forced
open.
Note that door contacts must be connected and that Door
monitoring must be activated for this to work.

18 V44 Duo Installation & User manual
ENG
This is how to choose one of the functions:
1 Press B and enter the current password.
2 Enter A69.
3 Enter either:
0 = Door Alert (default).
1 = Duress
Door monitoring on/off
If door contacts are used and this function is activated, a
warning signal sounds during the time set as door held
warning time, i.e. when the opening time has expired and
the door is still open.
If the door held warning time expires and the door is still
open, the alert output is activated (if the Alert function is
activated). This also happens if the door is forced open.
This is how to activate Door monitoring:
1 Press B and enter the current password
2 Enter A67.
3 Enter 1.
To deactivate Door monitoring, press 0 in step 3 instead.

V44 Duo Installation & User manual 19
ENG
Set door held warning time
If the door is still open when the opening time has expired, a
buzzer sounds as to remind the visitor to close the door im-
mediately – or the alarm output will be activated. The buzzer
sounds until the door is closed.
Note that door contacts must be connected and that Door
control must be activated for this to work.
This is how to change the door held warning time, if needed:
1 Press B and enter the current password.
2 Enter A29.
3 Enter the desired door held warning time (01-99) with
two digits, e.g. 09 for 9 seconds.
4 Choose to which relay outputs the new door held warn-
ing time should apply:
0 = both
1 = relay output 1
2 = relay output 2

20 V44 Duo Installation & User manual
ENG
Delay on/off
When this function is activated, the following happens: If a
code is programmed to open two doors, lock relay 2 is not
activated until door 1 has been opened and closed.
If door 2 is opened with the exit button, door 2 has to be
opened and closed before door 1 can be opened.
Note that door contacts must be connected and that Door
control must be activated for this to work.
This is how to activate Delay:
1 Press B and enter the current password.
2 Enter A80.
3 Enter 1.
To deactivate Delay, press 0 in step 3 instead.
Erase the memory
This is how to erase all programmed information (including
the password):
1 Press B and enter the current password.
2 Press SW1 on V44 Duo’s circuit board.
3 Enter 112186.
4 Enter 112186 once again. The memory is now erased
and V44 Duo goes back to the factory settings.
Table of contents
Languages:
Other Vanderbilt Lock manuals
Popular Lock manuals by other brands

Digi
Digi 6600-88 operating instructions

Cavity Sliders
Cavity Sliders CL100 Mortice Lock Fitting instructions

Assa Abloy
Assa Abloy Effeff 843G Installation and mounting instructions

Elka
Elka E 205 Installation and operating instructions

jablotron
jablotron CL-20A manual

TriTeq
TriTeq MicroIQ UT installation instructions