Varilight V-Pro Smart Supla User manual

INSTRUCTIONS FOR VARILIGHT
V-PRO SMART SUPLA DIMMERSWITCHES
OVERVIEW
Thank you for choosing a VARILIGHT V-Pro Smart intelligent
programmable rotary WiFi control dimmerswitch. Use only on an
electricity supply of 230 volts AC.
IMPORTANT: Read ALL sections below before installing this
dimmerswitch.
The V-Pro Smart master dimmer is suitable for 1-way circuits. For 2-
way (or multi-way) circuits, use a V-Pro Smart master dimmer with one
or more supplementary controllers. V-Pro Smart rotary WiFi dimmers
cannot be used in conjunction with conventional switches in a 2-way
circuit. Use only on an electricity supply of 230V~.
This product complies with European Safet Regulations (IEC 669-2-
1 or BSEN60669-2-1) when used in lighting circuits containing MCBs
(miniature circuit breakers). These can be rated at 6A, 10A or 16A
(preferably 6A for lighting circuits). Your guarantee is not affected if
you have an older lighting circuit protected by fuse wire links.
Do le & Tratt Products Ltd, Carylls Lea, Faygate, Horsham, W.
Sussex, RH12 4SJ, UK. +44 (01293) 223333
Varilight Europe Kft, 2600 Vác, Althann Mihály Frigyes utca 2,
Hungary.
LOADING
Maximum loads for V-Pro Smart Supla dimmerswitches (please see
www.varilight.co.uk for latest loading advice);
Alwa s observe the recommended maximum load.
Dimmer
Series
Lighting
Load
V-Pro Smart Supla
Max. Load Per Gang
Dimmable Mains
& Low Voltage
LEDs
1 to 10 Dimmable LEDs (max. 120W)
Check your LED lamps are suitable for use with
dimmers that have a standby mode. A load
regulator may be required, e.g. Varilight Glowfix
THIS SWITCH IS SUITABLE FOR
Most dimmable LEDs
THIS SWITCH IS NOT SUITABLE FOR:
Non-dimmable fluorescent bulbs and tubes;
Wire-wound or toroidal transformers;
Electric motors
OVERLOAD PROTECTION:
This dimmerswitch is protected against overload. If an overload occurs
it will automatically turn off until the overload is removed and the
dimmerswitch is switched off and then switched back on again.
However, if the dimmerswitch receives a total short-circuit it may be
damaged beyond repair.
TRANSFORMERS
Use only with quality dimmable electronic transformers. For optimum
performance choose VARILIGHT transformers*.
To calculate load, add the VA ratings of the transformers (not the
wattage of the bulbs). Choose transformers with a maximum rating
close to their lamp load (eg. Use a 50VA, 60VA or 70VA transformer
to control a 50W low voltage bulb).N.B. Certain transformers ma not
behave according to their power rating when used with a
dimmer. An overload will result in the dimmer turning itself off. If this
happens, change your transformer(s) (VARILIGHT transformer(s)
recommended); or remove one (or some) transformer(s) from the
circuit; or choose a higher rated dimmer instead. If a transformer
specifies Triac dimming, use a dimmer from the V-Com series.
* If a transformer appears as a highly inductive load, e.g. Wire-wound
or toroidal transformers, the dimmer will not work. To protect itself it
will turn off within 1 second.
ADVICE ON CHANGING LIGHT BULBS
Always turn off the mains power when light bulbs controlled by your V-
Pro Smart dimmers are replaced. If you change the type of light bulb
then restore factory settings as described under “Programming”.
FREQUENTLY ASKED QUESTIONS
For FAQs, please visit: www.varilight.co.uk faqs
GUARANTEE
In case of any defect, return the dimmer to our service department.
Varilight undertakes to repair or replace, at its discretion, goods which
have become defective within one year of purchase, solely as a result
of faulty materials and workmanship, provided that:-
a) The unit has been correctly fitted according to the instructions and
has not been used with an incompatible load, fluorescent tubes, or
overloaded beyond its rating, and has only been used on a 200-250V
a.c. power supply.
b) The dimmer module has not been tampered with or taken apart.
c) The unit is securely packed and safely returned to either address
listed in the overview section above, together with a letter stating the
guarantee registration number below, the date and place of purchase,
your contact details and return address, the type and wattage of the
lighting or other load being controlled and the details of the fault. This
guarantee states Varilight’s entire liability, which does not extend to
cover consequential loss or damage or installation costs arising from a
defective product. The guarantee does not apply to problems arising
from any incompatibility between your lamps and the dimmer switch.
This guarantee does not in any way affect the statutory rights of the
purchaser and is offered so that you may have the benefit of our
technical facilities.
In many cases products don’t need replacing, so for further information
and help with troubleshooting, see our FAQ page at
www.varilight.co.uk faqs, or contact our Customer Services by calling
+44 (01293) 223333 or create a support ticket at
www.varilight.co.uk help.
GUARANTEE REGISTRATION NUMBER SM002
FITTING YOUR DIMMERSWITCH
Read the instructions below carefully. Incorrect installation may
damage the dimmer beyond repair. In case of any doubt or difficulty
consult a qualified electrician.
1. Switch off at the mains, then remove the existing switch and
disconnect the wiring from the switch terminals at the rear, taking note
of the present wiring of the switch and the marking on the terminals.
Where there are two or more wires together in the old switch, they
must be kept together in the dimmerswitch.
2. Ensure that any wall box is free of plaster lumps or projecting screw
heads. Dimmerswitches on single-sized plates can be fitted to wall
boxes having 60.3mm screw fixing centres and those with double-
sized plates to wall boxes with 120.6mm fixing centres. Dimmers can
be fitted into a box with a minimum depth of 25mm for Classic plated
products, or 35mm for Ultraflat and Screwless. A box having 4 fixing
lugs cannot be used without modifying it. The top and bottom lugs
must be broken off or bent flat.
3. To connect the wiring for 1-way or 2-way circuits refer to the wiring
diagrams, or the text under the heading "1-Way, 2-Way and Multi-Way
Circuits" on the other side of this leaflet. Take care that no bare wires
project out of the terminals. Keep wires together in a terminal if they
were together in your old switch.
4. Dimmerswitches having a metal plate must be earthed by means of
the earthing point on the faceplate.
5. After connecting the wires screw the dimmerswitch gently into the
wall box so that the front plate is not distorted or cracked. Do not trap
the wiring between the rear of the dimmer and the back of the wall box.
6. Once installation is complete. Switch on the mains supply and
switch on the dimmer.
Important: Disconnect the dimmer before carrying out insulation
resistance testing. Failing to do so could damage a dimmer and make
the guarantee invalid.
www.varilight.co.uk J_SM
Please record the batch number printed on the
side of the plastic moulding on the rear of the
product. This will assist us in providing any
technical support you may require. Reg. SM002
BATCH NO:
INSTALLERS – Please leave these instructions with your customer for
future reference.
WARNING: Do not apply products with metal faceplates directly
to freshly plastered or damp surfaces as product may tarnish. If in
doubt, use polythene as a temporary gasket to protect the
product. Do not use masking tape on metal faceplates.

CONNECTING TO WIFI
For instructions on connecting this dimmer switch to WiFi, please see
the Supla Quick Start guide that came with the product. You will also
be able to connect to smart home systems such as Google Home and
Alexa once the Supla app has been set up.
If the Quick Start Guide has been misplaced, it can be found at
www.varilight.co.uk leaflets.
If you have any issues installing or using the app or creating an
account, please contact Supla for advice. Answers to FAQs can be
found here: https: www.supla.org en faq and further help can be
found at https: forum.supla.org.
PROGRAMMING
Programming is easily performed using the Supla app, with the
settings tab. This will allow you to instantly change the programming
settings with the press of a button.
The following settings can be changed with the app:
Factory Reset
Driving Mode
Boost function (for lights that don’t illuminate when turned on
at minimum brightness)
Operating range
Status LED
To get to the settings tab, select the dimmer using the Supla app, and
tap the cog in the bottom right corner (image 1). Sign in and you will be
presented with the settings screen (image 2). You can perform a
factor reset with the circular arrow at the top. The section below this
allows you to set modes 1, 2, or 3. Below this you can set the Boost
on or off. The operating range is edited with the wheel, by moving the
dark grey squares around the wheel. The left widget is for editing the
minimum brightness, the right for the maximum. The final setting,
Status LED, changes the behaviour of the small blue status LED
hidden behind the knob on the dimmer after the dimmer is connected
to the WiFi. The middle (default) icon sets the LED to turn on when the
WiFi connection drops. Alternatively select the icon on the left to set
the LED to stay on at all times or the icon on the right to turn it off
completely.
1. 2.
WIRING DIAGRAMS
CONTROL TIPS
There are some extra functions of this dimmer that can be used
alongside the regular push on off and rotary dim controls.
A sharp turn up will set the dimmers to maximum brightness, with a
sharp turn down setting them to minimum brightness. Either of
these can be performed from off. Turning the dimmer slowl in either
direction from off will bring the dimmers on at minimum brightness,
allowing you to ramp up from a very low level.
SUPLA APP CONTROL
To select a dimmer to control from the Supla home screen, swipe left
to bring the control screen forward. From here, there are 2 control
options at the bottom of the screen, wheel (1) or slider (2). You have
the same level of control with either, so choose whichever you prefer.
Drag the button around the wheel, or up and down the slider to dim,
and press the power button to switch on and off.
1. 2.
For extra Supla control options, including scheduling and channel
groups, please visit https: cloud.supla.org.
1-WAY, 2-WAY AND MULTI-WAY CIRCUITS
In 1-way lighting circuits the light(s) are controlled by one switch. This
dimmer should replace that switch. The live wire must be connected to
the terminal marked "LIVE" and the "load" wire to the terminal marked
"LOAD". To fit 2, 3 or 4-gang dimmers treat each group of terminals at
the back of the unit as a separate dimmer. You may also need a short
length of wire to connect together the "LIVE" terminals if only one live
wire is present.
For 2-way or Multi-way circuits (where the light(s) are controlled by
more than one switch) use this dimmer and any number of
V-Pro Smart supplementary controllers (total cable length
from the master to the last supplementary controller should
be no more than 50m) following the wiring diagrams below.
It is not possible to use a conventional switch in
combination with this type of dimmer. Follow the same
wiring as for 1-way circuits with three (or two) wires linking
each supplementary controller using the “LOAD” terminal,
“S-LINK” terminal and “LIVE” terminal. For more information
please refer to the wiring diagrams below.
Other Varilight Switch manuals
Popular Switch manuals by other brands

FS
FS S3900 Series Stacking Configuration Guide

Enterasys
Enterasys SecureStack A2 A2H254-16 Hardware installation guide

Minicom
Minicom 5UM60000 quick start guide

TP-Link
TP-Link T3700G-28TQ installation guide

Cybex Computer Products
Cybex Computer Products AV424 Installer and user guide

Pixelfly
Pixelfly PF-MS82T user manual