Vauban Systems VERSO+ Series Manual

TECHNICAL INFORMATION
VERSO+
VERSO+ 220
Versions 1,2 and 4 readers

2
Acknowledgement .................................................................................................. 3
Information and recommendations.......................................................................... 4
Technical characteristics......................................................................................... 5
VERSO+........................................................................................................................................... 5
VERSO+ 220.................................................................................................................................... 5
Compatibility.......................................................................................................... 5
Connecting a device using the wiegand or clock&data protocol ................................ 6
Connecting V-EXT4+ and V-EXT-IO ........................................................................ 7
CONNECTING A POWER LOSS BOLT AND AN ELECTROMAGNETIC DOOR LOCK
OPERATING ON POWER LOSS ................................................................................ 8
CONNECTING A STANDARD POWER-ON DOOR LOCK ........................................... 9
Connecting a push button and microswitch to the coffret 220 enclosure ................ 10
Connecting the power supply ................................................................................ 11
CONNECTING THE verso+ UNIT TO AN Ethernet NETWORK ................................. 12
Installation OF VISOR dongle................................................................................. 13
Use of the web server............................................................................................ 14
Functions of the terminals..................................................................................... 15
Use of the reset buttons........................................................................................ 16
Free installer hotline ............................................................................................. 17

3
ACKNOWLEDGEMENT
Dear client,
You have just purchased a “VERSO” unit manufactured by the French company Vauban Systems.
We thank you for your interest in our products.
If you want more information about our range, please visit our website www.vauban-systems.fr.
We wish you a trouble-free installation.
Vauban Systems

4
INFORMATION AND RECOMMENDATIONS
Pursuant to European directive UTE C00-200 incorporating directives 2004/108/CE,
VERSO+ complies with the following standards :
NF EN 50081-1 governing electromagnetic radiation,
NF EN 50082-1 governing electromagnetic susceptibility.
Cabling recommendations: the cables used to connect readers, the network and other
peripherals must be installed in accordance with the instructions for Level 2 (protected
environment) of standard NF EN 61000-4-4.
This product must be installed by an approved company. Incorrect installation and use
may result in electric shock or fire. Before installation, read the technical information and
comply with the recommendations for assembling the product.
For the 220V version, once the power is turned off, all the internal capacitors will
discharge themselves to a safe level after 60 seconds under normal conditions.
However, in the event of a power failure, the charge may be maintained for much longer
and suitable precautions should be taken before handling the product.

5
TECHNICAL CHARACTERISTICS
VERSO+
Maximum power consumption: 300 mA
Supply voltage: 9 –14VDC
Weight with housing: 257g
Housing dimensions: 170 x 116 x 40 mm
Operating temperature: 0°C à + 50°C
Control relay: 1A / 12V –1A / 24V
VERSO+ 220
Weight with housing: 4Kg
Housing dimensions: 365 x 310 x 90 mm
Operating temperature: 0°C à + 50°C
Alimentation 220V intégrée :
oOutput voltage: 12V
oMaximum output current: 3A et 2A
oBattery connection: 12V, 7Ah (dim. 151 x 97,5 x 65 mm)
or 12V, 18Ah (dim. 181 x 167 x 76 mm)
oControl relay: 1A / 12V –1A / 24V
COMPATIBILITY
The VERSO+ 2 unit is compatible with the version 2.0.0.20 of VISOR or higher.
The VERSO+ 1 and 4 units are compatible with the version 2.0.0.24 of VISOR or higher.
To download the latest version, you can use the link:
www.vauban-systems.fr/Visor.zip
The VERSO+ units is compatible with our modules V-EXT4, V-EXT4+, V-EXTIO et V-EXTLCD.

6
CONNECTING A DEVICE USING THE WIEGAND OR
CLOCK&DATA PROTOCOL
INFORMATIONS :
5 conductors (3 pairs recommended)
Max. distance: 100m (30m in RS485)
Cable type: 0.6 mm (SYT recommended)
Screen: Optional
WARNING: Do not install the unit-reader cables near other high voltage or high current cables,
particularly 220V or higher.
NOTE: Each reader can have different technology (e.g. Reader 1 using Wiegand, Reader 2 using
Clock & Data).
WARNING: If you use an external power
supply for your proximity readers, take care
to connect the various earths to that of the
unit.
+12V/200mA max
0V
DATA1 / CLOCK /A
DATA0 / DATA /B
Led
WIEGAND :
Proximity readers
(HID, STID, DESTEIR,
INDALA, …)
Key pads (XPR, …)
Biometric readers (MORPHO, …)
Radio receivers
(TECHNO EM, …)
CLOCK & DATA:
Magnetic strip readers
Barcode readers
Proximity readers
Radio receivers
RS485 :
DIGITOUCH MINI EXT
SSCP
OSDP

7
CONNECTING V-EXT4+ AND V-EXT-IO
You can also use the A and B terminals on the V-EXT4 modules to connect an RS485 bus.
INFORMATIONS :
2 conductors (2 pairs recommended)
Max. distance: 750 m
Cable type: 0.6 mm (SYT recommended)
WARNING: Do not install the cables near other high voltage or high current cables, particularly 220V
or higher. Use the same pair for the A and B lines.
Up to 10
modules per
VERSO+
Bus RS485

8
CONNECTING A POWER LOSS BOLT AND AN
ELECTROMAGNETIC DOOR LOCK OPERATING ON
POWER LOSS
WARNING: In order to prevent random malfunctions that may interfere with proper system
operation due to back-currents, it is imperative to use and connect the anti-back-current diodes
supplied with the unit in compliance with the cabling diagram above.
Even when using an additional uninterruptible power supply for locking separate to that of the unit, it
is obligatory to follow the above cabling diagram.
Power supply
+12V 0V
Anti-return diode

9
CONNECTING A STANDARD POWER-ON DOOR
LOCK
WARNING: In order to prevent random malfunctions that may interfere with proper system
operation due to back-currents, it is imperative to use and connect the anti-back-current diodes
supplied with the unit in compliance with the cabling diagram above.
Even when using an additional uninterruptible power supply for locking separate to that of the unit, it
is obligatory to follow the above cabling diagram.
Power supply
+12V 0V
Anti-return diode

10
CONNECTING A PUSH BUTTON AND
MICROSWITCH TO THE COFFRET 220 ENCLOSURE

11
CONNECTING THE POWER SUPPLY
PHASE
NEUTRAL
EARTH
+12V
0V
12V / 3A output
(door release)
+12V
0V
12V / 2A output
(control unit)
+12V
0V
Battery
F3A
F4A

12
CONNECTING THE VERSO+ UNIT TO AN
ETHERNET NETWORK
Each VERSO+ unit has an IP address. This address is printed on a sticker on the unit housing.
To configure a different IP address, you can use the “Automatic detection” menu in VISOR. To do
this proceed as follows:
Configure your PC static IP address near of the address range of the unit 192.168.2.xxx
Après avoir créé votre installation, au premier lancement, VISOR vous propose de créer une
nouvelle centrale
Click on the “Search” button
A list of detected units will appear
Double click on the unit you want to add
Check the equipment list to confirm that your unit is properly connected.
Crossed cable
Straight cable
Straight cable

13
INSTALLATION OF VISOR DONGLE
To use the VISOR software, you must, in certain cases (see following table), install a dongle on your
unit.
USE OF THE DONGLE
Number of readers in the installation
Software
Dongle
Up to 4 readers
VISOR LIGHT
No dongle required
Up to 10 readers
VISOR-10
Dongle required
Up to 40 readers
VISOR-40
Dongle required
Up to 80 readers
VISOR-80
Dongle required
Up to 140 readers
VISOR-140
Dongle required
Up to 840 readers
VISOR-840
Dongle required
Installation of dongle: with the power off, install the dongle as shown below:
To confirm proper operation, VISOR shows the version being used at the bottom of the main
screen. Your unit must be rated for the dongle to be detected.
If you do not have the correct dongle for your installation type, your units will be displayed
“rated” in the equipment list but no updates or event collection will be performed.

14
USE OF THE WEB SERVER
To access at the web server, launch your web browser and enter the IP address of the VERSO+ units.
A login and a password are required.
The default login is « admin » and the password is located on the label bonded on the housing.
You access to the home page.
According to the number of readers managed, a dongle may be required :
Number of readers in the installation
Software
Dongle
Up to 4 readers
VERSO WEB LIGHT
No dongle required
Up to 10 readers
VERSO WEB-10
Dongle required
Up to 42 readers
VERSO WEB-42
Dongle required

15
FUNCTIONS OF THE TERMINALS
GND
Power test
Auto protection
Ethernet network
GND
+ 12V
Standby
Common
Work
Repos
Common
Work
+12V / 1,5A max
GND
CLOCK / DATA1 / A
DATA / DATA0 / B
LED
GND
Push button
Door contact
Conditional entry
CLOCK / DATA1 / A
DATA / DATA0 / B
LED
GND
Push button
Door contact
Conditional entry
Open collecteur
Common
Work
GND
B
A
Dongle

16
USE OF THE RESET BUTTONS
Use this switch SW2 to restore the factory network settings
(IP address: 192.168.2.150, mask 255.255.255.0).
Turn off the power.
Hold the switch down while turning the power back on
To configure the unit in fixed IP mode, release the
switch when the blue LED of Extension bus first
activates (around 5 seconds).
To activate the product in DHCP mode, wait for the
blue LED of Extension bus to blink (around 5 seconds)
then wait for the blue LED to switch on a second time
(around 5 seconds).
Release the switch
Use this switch SW1 to clear the unit memory
Turn off the power.
Hold the switch down while turning the power back on
Wait for the blue LED of Extension bus to switch on
(about 10 seconds) holding the switch down
Release the switch

17
FREE INSTALLER HOTLINE
DO YOU HAVE ANY TECHNICAL
QUESTIONS?
CONTACT OUR FREE HOTLINE :
This manual suits for next models
7
Table of contents
Other Vauban Systems Card Reader manuals