USER MANUAL
Vauconsant SA, all rights reserved A329xx & A320xx -rev0-FR, 10th November 2009 - 7 -
Cleaning
Always take care to switch off the appliance with energy doser before cleaning. This unit is not
impermeable to water. Do not use a high pressure water jet to clean it inside or out.
Every day:
•Metal surfaces:
Stainless steel should be cleaned with soapy warm water or a special product for high quality
metal surfaces. Never use abrasive sponges or scourers to avoid scratching the surface.
•Toughened glass plates and display glass (breath shield):
Must be cleaned when cold, using a high quality glass cleaning product and clean cloth. Never
use abrasive sponges or scourers to avoid scratching the surface.
Diagnostic
Symptoms Possible causes Remedies
No electricity supply Check the general circuit breaker
Burnt fuse Check the fuse in the electric cabling
Orange light off
No heat Defective supply Check the supply cable
Defective toughened glass
plate Replace the toughened glass plate
Orange light on
No heat Cable disconnected or cut Check and test electricity input to the toughened glass
plates
Halogen bulb burnt Replace the bulb with one of equivalent power
A halogen lamp
does not come on Supply of this defective
halogen Check supply of halogen
No electricity supply Check the general circuit breaker
Burnt fuse Check the fuse in the electric cabling
Defective supply Check the supply cable to the heating display
None of the
halogen lights
come on Defective switch Check the switch, replace it if necessary
NB
•Bulbs should be replaced with bulbs of equivalent power. (see the Spare arts section)
•Fuses should be replaced by gG fuses of the same calibre.
Maintenance
Always remember to switch off the appliance by opening the fuse holder before any
maintenance operations.