manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. VDH
  6. •
  7. Thermostat
  8. •
  9. VDH ALFANET 31 User manual

VDH ALFANET 31 User manual

Other VDH Thermostat manuals

VDH ALFA 59 User manual

VDH

VDH ALFA 59 User manual

VDH ALFA 13 User manual

VDH

VDH ALFA 13 User manual

VDH ALFA 52-VS User manual

VDH

VDH ALFA 52-VS User manual

VDH ALFA 71 MODulation User manual

VDH

VDH ALFA 71 MODulation User manual

VDH ALFA 33DP User manual

VDH

VDH ALFA 33DP User manual

VDH ALFA D1-DP User manual

VDH

VDH ALFA D1-DP User manual

VDH ALFA 72-VS User manual

VDH

VDH ALFA 72-VS User manual

VDH ALFA-45A User manual

VDH

VDH ALFA-45A User manual

VDH MC 785-DF KLIMA User manual

VDH

VDH MC 785-DF KLIMA User manual

VDH ALFA 25 DP User manual

VDH

VDH ALFA 25 DP User manual

VDH ALFA 71 MOD User manual

VDH

VDH ALFA 71 MOD User manual

VDH ALFANET 71 User manual

VDH

VDH ALFANET 71 User manual

VDH ALFA 51 PI User manual

VDH

VDH ALFA 51 PI User manual

VDH ALFA(NET) 51 PI User manual

VDH

VDH ALFA(NET) 51 PI User manual

VDH ALFA 23 DP User manual

VDH

VDH ALFA 23 DP User manual

VDH MC 785D User manual

VDH

VDH MC 785D User manual

VDH ALFANET51 RTDN User manual

VDH

VDH ALFANET51 RTDN User manual

VDH ALFA 13 DP User manual

VDH

VDH ALFA 13 DP User manual

VDH ALFA 51 User manual

VDH

VDH ALFA 51 User manual

VDH PROBA 5 Compact User manual

VDH

VDH PROBA 5 Compact User manual

VDH ALFA 23 User manual

VDH

VDH ALFA 23 User manual

VDH ALFA 71 User manual

VDH

VDH ALFA 71 User manual

VDH ALFA 71 PI User manual

VDH

VDH ALFA 71 PI User manual

VDH ALFANET 55 RTDF User manual

VDH

VDH ALFANET 55 RTDF User manual

Popular Thermostat manuals by other brands

Full Gauge TIC-17C product manual

Full Gauge

Full Gauge TIC-17C product manual

Imit Chronomix S manual

Imit

Imit Chronomix S manual

ChiliTec ST-35 ana instruction manual

ChiliTec

ChiliTec ST-35 ana instruction manual

Salus VS05 Installer's/user's manual

Salus

Salus VS05 Installer's/user's manual

Azel D-500 user guide

Azel

Azel D-500 user guide

Honeywell Chronotherm III owner's manual

Honeywell

Honeywell Chronotherm III owner's manual

Charmeg MP-R user manual

Charmeg

Charmeg MP-R user manual

dixell WING XW40LS Installing and operating instructions

dixell

dixell WING XW40LS Installing and operating instructions

Network Thermostat NetX X7C-WIFI Installation and programming manual

Network Thermostat

Network Thermostat NetX X7C-WIFI Installation and programming manual

Radio Thermostat CT80 Operation guide

Radio Thermostat

Radio Thermostat CT80 Operation guide

HAI Omnistat RC-120 installation manual

HAI

HAI Omnistat RC-120 installation manual

Lennox iComfort E30 Installation and setup guide

Lennox

Lennox iComfort E30 Installation and setup guide

Lux Products PSD011Ba Installation and operating instructions

Lux Products

Lux Products PSD011Ba Installation and operating instructions

Computherm Q20 operating instructions

Computherm

Computherm Q20 operating instructions

Heatmiser neoStat user manual

Heatmiser

Heatmiser neoStat user manual

Mars HEAT CONTROLLER IR Wireless Thermostat user manual

Mars

Mars HEAT CONTROLLER IR Wireless Thermostat user manual

LUX LP0511D user manual

LUX

LUX LP0511D user manual

Saswell SAS920XWHB-7-S-RF User manual and warranty card

Saswell

Saswell SAS920XWHB-7-S-RF User manual and warranty card

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
User manual ALFANET 31
Cool/Heat Thermostat.
VDH doc. 032679 Version: v1.0 Date: 24-11-2003
Software: ALFA31 File: Do032679.WP8 Range: -50/+50°C per 1°C
*Installation.
On the topside of the ALFANET 31 you can see how the sensor, power supply and relay have to be
connected.
After connecting the ALFANET 31 to the power supply, a self test function is started. As this test is
finished, the measured temperature appears in the display.
When the relay is activated, the led 'on' will light-up in the display.
And the ALFANET 31 is by use of the ALFANET PC-INTERFACE controllable on the PC.
*Control.
The ALFANET 31 thermostat can be controlled by three pushbuttons on the front. These keys are;
SET - view / change the setpoint.
UP - increase the setpoint.
DOWN - decrease the setpoint.
*Viewing setpoint.
By pushing the SET key the setpoint appears in the display. The led 'set' starts blinking. A few
secondsafter releasing the SETkey the setpoint disappears and the measured temperature is shown
in the display.
*Changing setpoint.
Push the SET key and the setpoint appears in the display. Release the SET key. Now push the SET
key again and together with the UP or DOWN keys the setpoint can be changed. A few seconds after
releasing the keys the measured temperature shows again in the display.
2
*Setting internal parameters.
Next to the adjustment of the setpoint, some internal settings are possible like differential, sensor-
offset, setpoint range and the function cooling or heating.
By pushing the DOWN key for more than 10 seconds, you enter the 'internal programming menu'. In
the left display the upper and lower segment, are blinking. With the UP and DOWN keys the required
parameter can be selected (see the parameter table).
If the required parameter is selected, the value can be read-out by pushing the SET key. Pushing the
UP or DOWN keys, together with the SET key allows you to change the value of this parameter.
If after 20 seconds no key is pushed, the ALFANET 31 changes to its normal operation mode.
*Adjustment sensor.
The sensor can be adjusted by using the Sensor Offset (parameter 04). Indicates the ALFANET 31
e.g. 2°C too much, the Sensor Offset has to de decreased by 2°C.
*Error messages.
In the display of the ALFANET 31 the following error messages can appear:
Er - Sensor broken. Solution:
- Check if the sensor is connected correctly.
- Check the sensor (1000Ωat 25°C).
- Replace the sensor.
EE - Settings are lost. Solution:
- Reprogram the settings.
* Technical details.
Model : ALFANET 31
Range : -50/+50°C, readout per 1°C
Supply : 230 Vac (or 24Vdc or 12Vdc)
Relay : SPDT 250V/16A(C-NO), 8A(C-NC) (cos phi=1)
Communication: RS485-Network (A,B,GND 2-wire shielded)
Control : by pushbuttons on the front.
Front : Polycarbonate IP65
Sensor : SM 811/2m (1000Ωat 25°C)
Sizes : 35 x 77 x 71,5mm (hwd)
Panel hole : 28 x 70mm (hw)
- Provided with memory protection during power failure.
- Connection with screw terminals on the back side.
- Equipped with self test function and sensor failure detection.
- Special versions are available upon request.
3
*Parameters ALFANET 31.
PARA-
METER DESCRIPTION PARAMETER RANGE STANDARD
VALUE
01
02
03
04
Switching differential
Minimum setpoint
Maximum setpoint
Offset temperature sensor
1..15°C
-50..+50°C
-50..+50°C
-15..+15°C
3
-50
+50
0
10
11 Startup delay after power failure
Relays on at sensor failure 0..99 min.
0 = No
1 = Yes
0
0
15
16
17
18
19
20
Function cooling or heating
Switch on delay relays 1)
Switch off delay relays 1)
Parameter 16/17 in sec. or min.
Minimum on-time relays
Minimum off-time relays
0 = Cool
1 = Heat
0..99
0..99
0 = sec.
1 = min.
0..99 min.
0..99 min.
0
0
0
0
0
0
52 Time correction (at realtime clock) -99..+99 0
90
95
96
97
98
99
Network number
Software version
Production year
Production week
Serial number (x1000)
Serial number (units)
1..31
0..255
00..99
1..52
0..255
0..999
1
-
-
-
-
-
1) On active delay led 'on' blinks.
*Address.
VDH Products BV Tel: +31 (0)50 30 28 900
Produktieweg 1 Fax: +31 (0)50 30 28 980
9301 ZS Roden Email: [email protected]
The Netherlands Internet: www.vdhproducts.nl
* Function Diagram.
4
*Dimensions.
*Connection Diagram.