INSTRUCTION MANUAL
EURO24PR
WARNING!! Before installing, thoroughly read this manual that is an integral part of this Kit.
VDS declines any responsa-bilità in the event curret stadards in the country of installation are not comlplied with.
Electronic control panel for one 24Vdc motor
ELETTRONIC DIVISION
OPTIONS SELECTOR
The maneuvers are executed through the Alternative button (Test button on the motherboard, or Alternative switch terminals, or by radio card).
The maneuvers ends for one of the following conditions: activation of the corresponding end switchs orby the end of operating time.
If during the opening operation is given an order, the action is stoped and do not run the closing.
Stop button activation causes immediate stop of the maneuver, requiring an order for the resumption of it.
Activation os safety switch input during closing, inverts it and goes to open position.
Input battery alimentation.
Garage light is activated during 0.5 sec. before starting the opening operation and is turned off 2 sec. after it.
Courtesy light at the opening (if allowed) flashes slowly, and on closing flashes quickly. In open position courtesy light is ON.
Drive power regulation selected in R. FORCE, it will be applied after 2 sec. Of the maneuvre.
OPERATING INSTRUCTIONS
Instruction Manual
In order to program functions the control panel should be in a stable state with the door closed.
Option number 3 must be turned OFF. If we want buffer closing I7 must be turned ON and if we have an encoder DIP switch number 8 must be turned ON too.
Push button PROG TIEMPOS for 1,5 secs. The red LED will light up indicating that the panel is ready for time programming. Now we can proceed. In order to stop
programming press button PROG for 1,5 secs again with the door in 'resting' position; the process requires that a full opening and closing cycle is completed.
To program working times with pedestrian button press PROG button for 1-5s-Let and press the button for 1.5s and programming LED will turned ON. With pedestrian
Button we will start the programming time function-
Programming times process
1) The door must be closed. Activate as described above. The red LED lights up.
2) Push "START" button to open the door.
Pushing "START" again will stop the door and will memorize the time of opening. If opening is finalized by limit switch open (LSO), the programme will memorise times
+ 4 sec.
3) Once the door is open, the closing time will be memorized automatically until the closing operation has begun.
4) Push"START" button to close the door.
I7 OFF - Pushing "START” again will stop the door and memorize the closing time. If closing is finalized by limit switch (LSC), the programme will memorise
times + 4 sec.
I7 ON - Pushing "START” button again, drive reduce the speed (buffer closing), and pressing it again, the manoeuvre will stop and closing time, and buffer
closing will be memorized. If the manouvre is finalized by limit switch open (LSO), the programme will memorise times + 4 sec.
5) Upon completing a full cycle of the door programming will be automatically finalized.
The maximum memorization time is 2 minutes, if you wait more, this limit will be memorized.
DIGITAL PROGRAMMING of open, close & automatic close.
GB
OPTION 1 - Sectional / Sliding Gate
OPTION ON Door closes automatically after waiting the a.c. time.
OFF Door does not close automatically.
OPTION ON Alternative button stops and invert at close. Disable stop opening.
OFF Alternative button stops.
OPTION ON Invert drive direction.
OFF Normal drive direction.
OPTION 5 - Pneumatic Band with Stop Options
ON Input Cseg1 works like security band, stopping opening and closing.
OFF Input Cseg1 works like security band, stopping the closing and stop &
inverts 2 sec. in the opening.
OPTION 6 - Flashing Light
ON Flashing
OFF Fixed
OPTION 7 - Buffer Closing
ON Drive reduce it’s speed at the end of opening & closing.
OFF No buffer.
OPTION 8 - Enconder Yes/No
ON Enable encoder input.
OFF Disable encoder input.
ON Sectional.
OFF Sliding.
2 - Automatic Closing
3 - Door Stop & Inverts and Disable Stop Opening
4 - Drive Direction
OPTIONS SELECTOR
EURO24PR
CANCELLATION OF ALL CODES
- Here we have to reset the memory.
- Press PROG/RES for 3,5 seconds.
- After 1,5 seconds one acoustic signal will be heard indicating that you have entered the
code memorization mode, maintain the button pressed.
- After 3,5 seconds you will hear a series of acoustic signals.
- Stop pressing the button.
- The receptor will have cancelled all codes.
- The System stays in memorization mode, ready to receive new codes (see system a)
FIRMWARE
CODE MEMORITZATION
Manual memoritzation
- Press button PROG/RES for 1,5 sec.
- On hearing the acoustic signal stop pressing as the receptor will be logged onto the memorizing code
sequence. - From this moment received codes will be memorized.
- In order to memorize push any button on the transmitter.
- The memorization of a code is confirmed with one acoustic signal.
- The receiver will exit automatic memorization code sequencing after 10 seconds from the last code input. This will be indicated with two acoustic signals. Emergency
exist of the automatic memorization code sequencing can be done by pushing the special function button on one of the transmitters which is being coded (within 10
seconds). Semiautomatic memorization
- In order to activate this system must have memorized at least one code into the receiver.
- Push the special function button on one of the transmitters which have been codified.
- On hearing one acoustic signal or when PROG led will turned ON, stop pushing and the receiver will have entered into code memorization
sequence. - From that moment.. follow the steps of manual memoritzation.
Alimentation 24V AC
Motor Tension 24V DC
Motor Current Max. 2,5A
Output Accessory Alimentation
Light Contact N.O.
Flash Contact N.O.
2 minutes
3 sec. a 2 minutes
Radio Card
24V DC 150mA
Working Time
Automatic Closing Time Internal
Working Temperature -20 to 70ºC
TECHNICAL SPECIFICATIONS
FLASH
LIGHT
8 9
ALIMENTATION BATTERY MOTOR
PUSH
BUTTONS
TERMINALS
STANDARD CONTROL PANEL SET UP
TERMINAL DESCRIPTION
REGULATIONS
STRENGTH MOTOR REGULATION (GREEN)
Regulation the strength of motor.
Rotate LEFT to decrease and
rotate RIGHT to increase.
Regulates drive power
Turn LEFT to decrease and
RIGHT to increase
DRIVE POWER (RED)
+
--
+
ACCESSORIES
POWER SUPPLY
24V
10 11
LIMIT
SWITCH
SAFETY
SECURITY COSTA
& PHOTOCELL
12 13 14
ANTENNA
ANTENNA
27 28
15 16 17
LSO - OPEN
LSC - CLOSE
ENCODER
MOTOR
M
2
1
ENCODER
4 5
3
S
Vcc
START
BUTTON
PED ES.
BUTTON
20 21 22
24V
23 24
STOP
18 19
STOP
Instruction Manual
FLASH
6 7
GB
EURO24PR
WARNING!!
AN ACCESSIBLE SWITCH, TO TURN OFF THE EQUIPMENT MUST BE INSTALLED FOR SYSTEMS THAT
ARE ALWAYS CONNECTED.
BEFORE INSTALLING MAKE SURE THE SUPPLY VOLTAGE IS SWITCHED OFF.
24V
1095 Budapest, Mester utca 34.
Tel.: *218-5542, 215-9771, 215-7550,
216-7017, 216-7018 Fax: 218-5542
Mobil: 30 940-1970, 20 949-2688
E-mail: delton@delton.hu Web: www.delton.hu
www.kaputnyitunk.hu
1141 Budapest, Fogarasi út 77.
Tel.: *220-7940, 220-7814, 220-7959,
220-8881, 364-3428Fax: 220-7940
Mobil: 30 531-5454, 30 939-9989

Other vds Control Panel manuals

vds EURO230M1 User manual

vds

vds EURO230M1 User manual

vds EURO380 M1 User manual

vds

vds EURO380 M1 User manual

vds EURO230M2 User manual

vds

vds EURO230M2 User manual

vds EURO 230 M1 ECO User manual

vds

vds EURO 230 M1 ECO User manual

Popular Control Panel manuals by other brands

Siemens MJ-XL Installation and operation manual

Siemens

Siemens MJ-XL Installation and operation manual

Bticino 352500 manual

Bticino

Bticino 352500 manual

Schrack Integral MAP Quick user manual

Schrack

Schrack Integral MAP Quick user manual

MCZ MAESTRO 4021004 installation guide

MCZ

MCZ MAESTRO 4021004 installation guide

auto maskin Marine Pro 200E Series Configuration manual

auto maskin

auto maskin Marine Pro 200E Series Configuration manual

Votronic VPC Jupiter 100 Installation and operating manual

Votronic

Votronic VPC Jupiter 100 Installation and operating manual

WhisperPower WhisperTouch WP-TOUCH 5 User & installation manual

WhisperPower

WhisperPower WhisperTouch WP-TOUCH 5 User & installation manual

Pro-tec 6100 user manual

Pro-tec

Pro-tec 6100 user manual

TIFATECH HTCLG instruction manual

TIFATECH

TIFATECH HTCLG instruction manual

Pyronix STERLING 10 user manual

Pyronix

Pyronix STERLING 10 user manual

ALL TUBE-LIGHT operating guide

ALL

ALL TUBE-LIGHT operating guide

Harvia Xenio CX004WIFI Instructions for installation and use

Harvia

Harvia Xenio CX004WIFI Instructions for installation and use

CAME ZC3 installation manual

CAME

CAME ZC3 installation manual

Amperes RP1104 instruction manual

Amperes

Amperes RP1104 instruction manual

SALUPO RAIN PLUS 1 Instruction and installation manual

SALUPO

SALUPO RAIN PLUS 1 Instruction and installation manual

Galletti MCA 10 M manual

Galletti

Galletti MCA 10 M manual

Aprilaire 6302 Safety & installation instructions

Aprilaire

Aprilaire 6302 Safety & installation instructions

AVE AF909RS manual

AVE

AVE AF909RS manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.