Veichi AC300 Series User manual

20 18

CONTENT
Chapter 1 Overview.........................................................................................................................................................1
1.1Safetyrequirementandcautions......................................................................................................................................................1
1.2BeforeUse..........................................................................................................................................................................................1
1.3Technicalcriterion...............................................................................................................................................................................2
Chapter 2 Installation......................................................................................................................................................4
Chapter 3 Keyboard layout and functions specification..........................................................................................8
Chapter 4 Function Parameter Table...........................................................................................................................9
4.1Basicparameters...............................................................................................................................................................................9
4.2 Terminalof InputandOutputFunctionSelection..........................................................................................................................30
4.3MonitorCode....................................................................................................................................................................................31
4.4FaultCode........................................................................................................................................................................................33
Chapter 5 Periodic Overhaul and Maintenance........................................................................................................34
5.1Overhaul............................................................................................................................................................................................34
5.2Maintenance.....................................................................................................................................................................................35
Appendix: Modbus Communication Protocol..........................................................................................................36

1
Chapter 1 Overview
1.1 Safety requirement and cautions
Pleasedototallyunderstandthispart beforeusingtheinverter.
Warning signs and meanings
Thismanualhasusedfollowingsignswhichmeansthereisanimportantpartofsecurity.Whileobservingagainst therules,thereisa dangerof
injuryevendeathormachine systemdamage.
Danger:Wrongoperationmaycausedeath orlargeaccident.
Caution:Wrong operation maycauseminorwound.
Operation requirement
Onlyprofessionallytrainedpersonscanbeallowedtooperatetheequipment.“Professionaltrainedpersons“meanstheworkersmusthave
experienceprofessionaltrainedskill,andmustbefamiliarwithinstallation,wiring,runningandmaintainandcanrightly dealwithemergencycases
inuse.
Safety guidance
Warningsignscomeforyour security.Theyaremeasurestopreventtheoperatorand machinesystemfromdamage.Please carefully read this
manualbeforeusingandstrictlyobservetheregulationsandwarningsignswhileoperating.
●Correcttransportation,store,installation, carefuloperation andmaintenanceareimportantfor invertersafeoperation. Intransportandstore
process,makesuretheinverterisfreefromimpactandvibration.Itmustbestoredwhereisdrywithoutcorrosiveairand conductivedust,and
thetemperature mustbelowerthan60℃.
●Thisproductcarriesdangerousvoltageandcontrols drivermachinewithpotentialdanger.If youdon’tabidebytheregulationsorrequirementsin
thismanual,thereisdanger ofbodyinjuryevendeathandmachinesystemdamage.
●Donotwirewhilethepowerisconnected.Otherwise,thereisdangerofdeathforelectricshock.Beforewiring,inspectionandmaintenance,
pleasecutoffpowersupplyofallrelatedequipment’sandensuremainDCvoltageinsaferange.And pleaseoperateitafter 5mins.
●Powerwire,motorwireandcontrolwireshouldbeallconnectedfirmly. Earthmustbereliableandearthresistancemustbelower than 10Ω.
●Humanbodyelectrostaticwilldamageinnersensitivecomponentsseriously. Beforeoperation,pleasefollowESDmeasures.Otherwise, thereis
dangerofinverterdamage.
●Inverteroutputvoltageispulsewave.Ifcomponentssuchascapacitorwhichimprovespowerfactorandpressure-sensitiveresistancefor
anti-thunderandsoonareinstalledattheoutputside,pleasedismantlethemorchangeto inputside.
●Noswitchcomponentssuchasbreakerandcontactorattheoutputside(Iftheremustbeone,pleasemakesuretheoutputcurrentis0whilethe
switchacting).
●Nomatterwherethefaultis,thereisdangerof seriousaccident.Sothere mustbeadditional externalpreventmeasuresorother safetydevices.
●Onlyusedinapplicationfieldsasmakerstated.Nouseinequipmentsrelatedtospecialfieldssuchas emergency,succor, ship,medical
treatment,aviation,nuclearandetc.
●OnlyVeichiElectricco.,ltdservicedepartmentoritsauthorizedservicecenter canmaintaintheproducts.Itmay causeproductfaultwhileusing
accessoriesnotauthorizedorpermitted.Anydefectivecomponentsmust bechangedintimein maintenance.
1.2 BeforeUse
Onreceivingyourorder,pleasecheckthepackageandconfirmintactbeforeopening,andcheckifthere’sanydamage,scratchordirt(damages
causedduringtransportationarenotwithinthecompany'swarranty).Ifthere’sanydamagecaused duringtransportation,pleasecontactus orthe
transportcompanyimmediately.Afterconfirmingthe receiptofthegoodsintact,pleasere-confirmiftheproductandyourorderareconsistent.

2
VFD Model
Input Model
Input Model1
Input Model2
Serial No.
Product
Series
AC300 - T 3 - 011 G /015P-B
Symbol Voltage
2220V
3380V
6660V
T 3-Phase
SSingle
Phase
Code VFD Type
GGeneral
Code Adaptive motor (KW)
7R5
011 7.5
11
018
132 18.5
132
11 1140V
AC300
PBlower & Pump
Symbol Code Accessories type
BBrakeUnit
Phase
Symbol
Voltage 220V 380V 660V 1140V Voltage 220V 380V 660V 1140V
Power RatedOutputCurrent(A) Power RatedOutput Current(A)
0.7
5
4 3
110 380
210
121
7
5
1.
5
7 4
132 420
250
150
8
6
2.2 10 6
160 550
310
17
5
10
5
4 1
6
10
18
5
600
340
19
8
11
5
5.
5
20 1
3
200 660
380
21
8
132
7.
5
30 1
7
10
220 720
41
5
23
5
144
11 42 2
5
1
5
250
470
270
162
1
5
5
5
32 1
8
280
510
330
17
5
18.
5
70 3
8
22
31
5
600
34
5
20
8
22 80 4
5
2
8
35
5
670
380
220
30 110 60 3
5
400
750
430
260
3
7
130 7
5
4
5
2
5
450
810
46
6
270
4
5
160 90 52
31
500
860
540
32
5
5
5
200 110 6
3
3
8
560
990
600
36
5
7
5
260 150 8
6
52
630
1100
680
400
90 320 180 9
8
5
8
710
1260
760
450
1.3 Technical criterion
Items Criterion
Power
input
Voltage,frequency Threephase380V 50/60Hz,
Allowablefluctuations voltageunbalancerate:<3%;Frequency:±5%;aberrationrate:asIEC61800-2required
Inrushcurrent Lowerthan ratedcurrent
Powerfactor ≥0.94(withDCreactor)
Efficiency ≥96%
Output
Outputvoltage Outputunderratedcondition:3phase,0~inputvoltage, inaccuracy<5%
Outputfrequencyrange Gtype:0~600Hz
Outputfrequencyaccuracy Maxfrequency±0.5%
Overloadcapacity Gtype:150%ratedcurrent/1min, 180%ratedcurrent/10s,200%ratedcurrent/0.5s
Main
Control
performance
Steadyspeedaccuracy V/F withoutPG,VCwithout PG,V/FwithPG,VCwithPG
Startingtorque OptimizedSVPWMmode
Steadyspeedaccuracy 0.7~16.0kHz
Startingtorque VC withoutPG:ratedload1:100;VCwithPG:ratedload1:1000
Steadyspeedaccuracy VCwithoutPG: ≤2% ratedsynchronizedspeed;VCwithPG:≤0.05%ratedsynchronizedspeed

3
Startingtorque VC withoutPG:when0.5Hz,150%ratedtorque;VC withPG:when0Hz,200%ratedtorque
Torqueresponse VCwithoutPG: ≤20ms;VCwithPG:≤10ms
Frequencyaccuracy Digitsetting:maxfrequency×±0.01%;Analogsetting:maxfrequency×±0.2%
Frequencyresolution Digitsetting:0.01Hz;Analogsetting:maxfrequency×0.05%
Basic
functions
DCbrakingcapacity Starting frequency:0.00~50.00Hz; Brakingtime:0.0~60.0s;Brakingcurrent:0.0~150.0%ratedcurrent
Torqueboostcapacity Autotorqueupgrade0.0%~100.0%;Manualtorqueupgrade0.0%~30.0%
V/Fcurve 4modes:onelinearitytorquecharacteristic curve,oneself-settingV/Fcurvemode,onedrop
torquecharacteristiccurve(1.1-2.0powers),andsquareV/F curvemode.
Acceleration/Deceleration
curve 2modes:linearAcceleration/Decelerationand ScurveAcceleration/Deceleration.4 setsof
ACC/DEC,timeunit0.01sselectable,longesttime:650.00s.
Ratedoutputvoltage Relyon powersupplyvoltagecompensatefunction,whilemotorratedvoltageis100%,setitat
therangeof50-100%(outputcannotoverinputvoltage).
Voltageauto-adjustment Whilepowersupplyvoltagefluctuates,itcanauto-keepconstantoutputvoltage.
Autoenergy-savingrunning WhileunderV/Fcontrolmode, accordingtoloadsituation,auto-optimizeoutputvoltagetosave
energy.
Auto-limitcurrent Auto-limitthe currentwhilerunningtoprevent overcurrentbreaktrouble.
Instantpowerofftreatment Whileinstantpoweroff,realizecontinualoperationbybusvoltage control.
Standardfunctions PIDcontrol,speedtrack,poweroff restart,jumpfrequency,upper/lowerfrequencylimitcontrol,
programoperation,multi-speed,RS485,analogoutput,frequencyimpulseoutput.
Frequencysettingchannels Keyboarddigitalsetting,Analogvoltage/currentterminalAI1,Analogvoltage/currentterminalAI2,
Communicationgivenandmulti-channelterminalselection,Mainandauxiliarychannel
combination,expansioncard, supportingdifferentmodes switch
Feedbackinputchannel Voltage/CurrentTerminalAI1, Voltage/CurrentTerminalAI12,Communicationgiven,Low-speed
pulseinputPUL,extensioncard
Runningcommandchannel Operationpanelgiven,externalterminalgiven,communicationgiven,expansioncard given
Inputcommandsignal Start,stop,FWD/REV, JOG,multi-stepspeed,freestop,reset,ACC/DECtimeselection,
frequencygivenchannelselection,exteriorfaultalarm.
Exterioroutputsignal 1relayoutput,1 collectoroutput,1AO output:0~10Voutputor4~20mAoutput,orfrequency
pulse output
Protectionfunction Overvoltage,under-voltage,currentlimit,over-current,overload,electric thermalrelay, overheat,
overvoltagestall,dataprotection,rapidspeedprotection,input/outputphasefailureprotection
Keyboard
display
LEDdisplay Singlefile5digitaltubedisplay Canmonitoronestatevariable
Twofile5digitaltubedisplay Canmonitor twostatevariables
Parametercopy Canuploadordownloadfunctioncodeinformationofinvertertorealizefastparametercopy.
State monitor Outputfrequency,givenfrequency, outputcurrent,input voltage,outputvoltage,motorspeed,
PIDfeedback,PID
g
ivenvalue,moduletem
p
eratureetc.
monitor
p
arameters.
Faultalarm ,Over-voltage,under-voltage,over-current,shortcircuit,phasefailure,overload,overheat,
overvolta
g
estall,current limit,ordata
p
rotectiondestro
y
ed;Faultrunnin
g
state; Fault histor
y
.
Environme
nt
Installplace altitude≤1000m,above1000mdowntheratedamount,eachincreaseof100mdowntherated
amountof1%;nocondensation,ice,rain,snow, hail;solarradiationbelow700W/㎡, airpressure
70-106kPa
Temperature, humidity -10~+50 ,above40 downthe ratedamount,t℃℃ hemaxtemperature:60 (noloadrunning)℃
Vibration 9~200Hz,5.9m/s2(0.6g)
Storetemperature -30—+60℃
Installation Hangingtype,cabinettype
Protectiondegree IP20
Coolingmode Forced air cooling

4
Chapter 2 Installation
Thissectionspecifiestheconsiderationsnecessaryforreliableandsafeoperationoftheproductbyusers.
Overall Dimension of Inverter (Plastic)
MODEL OverallDimension(mm) Installation Dimension(mm) Apertu
re
W H H1 D D1 W1 W2 H2 A B
AC300-T3-R75G/1R5P-B
76 200 192 155 149 65 65 193 5.5 4 ф3-M4
AC300-T3-1R5G/2R2P-B
AC300-T3-2R2G-B
AC300-T3-004G/5R5P-B 100 242 231 155 149 84 86.5
231.5 8 5.5 ф3-M4
AC300-T3-5R5G/7R5P-B
AC300-T3-7R5G/011P-B 116 290 277.5 175 169 98 100 277.5 9 6 ф3-M5
AC300-T3-011G/015P-B
AC300-T3-015G/018P-B
140 360 349.5 225 219 120 120 350 10 6 ф4-M5
AC300-T3-018G/022P-B
AC300-T3-022G/030P-B
AC300-T3-030G/037P 172 430 / 225 219 150 150 416 11 7.5 ф4-M5
AC300-T3-037G/045P

5
Overall Dimension of Inverter(Steel)
安装直径
MODEL OverallDimension(mm) Installation Aperture
W H D H2 W1 H1
AC300-T3-045G/055P 225 523 290 500 176 509 ф7
AC300-T3-055G/075P 225 523 290 500 176 509 ф7
AC300-T3-075G/090P 240 570 340 535 176 551 ф9
Installation Diameter

6
StandardConnectionDiagram
Note2
Note:Function description in brackets is
factory default
Note1
Analog monitoring
signal output
TA
TB
TC
+24V
Y
Shielded cable (the
end close to VFD
grounding)
_
mA
20
10
0
-
+
V
W
U
M
~
Shielded cable or armoured cable
(the end close to VFD grounding)
E(The grounding resistance
is less than 10 ohms)
W
V
U
Output Rector
External DC Rector
External
Brake
Resistor Short
Piece
P1
+
( )
R
External Brake Unit
+10V
Frequency control input
R
T
S
AC POWER INPUT
GND
AI1
AI2
Shielded cable (the end close to
VFD grounding)
Multi function contact input
(REV JOG)
(FWD JOG)
(Reverse)
(Forward)
(Free STOP)
COM
X3
X4
X5
X1
X2
PB
( )
+
(-)
VFD
S
T
R
GND
A0
Coil
COM
Passive contact
output
AC220V
AC0V
Coil
MAX Output Of Contact:
3A/240VAC
5A/30VDC
1.MAX Output of +24V Port:DC24V/100mA
Note:When output type of AO port as
frequency and Voltage,
Maximum Output:2mA
2.Inner resistance of AI1/AI2 Port
1.MAX Output of +10V port :50mANote:
2.Max Output of Y Port :DC24V/50mA
Note:
represent control circuit terminals.
represent main circuit terminals;
Legend: 1.Symbol
Shielded cable
(the end close
to VFD grounding)
Input Rector
ContactorMCCB +
( )
PUL
+24V
PLC
COM
Analog Voltage/Current quantity input
A+
B-
RS485 Differential
Communication 120Ω
Open collector(OC)
state output
Analog Voltage/Current quantity input
2.Symbol
Note:1.WheninstallingDCreactor,makesureto dismantletheshort connectorbetweenterminalP1and(+).
2.NPN orPNPtransistorsignalcanbeselectedasinputofmulti-functioninputterminal(X1~X5/PUL). Inverterbuilt-inpowersupply
(+24Vterminal)orexternalpowersupply(PLCterminal)canbechosenasbiasvoltage.Factorysetting ‘+24V’shortconnectwith
‘PLC’,whichlocatesbetweenRJ45andterminals.
3.Analogmonitoroutputisthespecial outputformeterssuch asfrequencymeter,currentmeterandvoltagemeter.It can’tbeusedfor
controloperationssuchasfeedbackcontrol.
4.Astherearemultipulsestyles,pleasereferto thelineconnect modedescriptiondetails.
●AuxiliaryTerminalOutputCapacity
Terminal FunctionDefinition MaxOutput
+10V 10Vauxiliarypowersupplyoutput,constitutesloopwithGND. 50mA
A0 Analogmonitoroutput,constitutesloopwithGND. Maxoutput2mAasfrequency,voltagesignal
+24V 24Vauxiliarypowersupplyoutput,constitutesloopwithCOM. 100mA
Y Collectoropencircuitoutput;cansettheaction-objectby
program. DC24V/50mA
TA/TB/TC Passiveconnectoroutput;cansettheaction-objectbyprogram.
3A/240VAC

7
●FunctionSpecificationof SwitchTerminals
SwitchTerminal SelectingPosition FunctionSpecification
RS485TerminalResistor
RS485Communication
:connectwith120Ωterminalresistor
AOOutput-frequency AO2:0.0~100kHzfrequencyoutput
AOOutput-Current AO2:0~20mAcurrentoutputor4~20mAcurrent output
AOOutput-Voltage 0~10Vvoltageoutput
AI1Input-Current/Voltage AI1:Input0~20mAor0~10V
AI2Input-Current/Voltage AI2:Input0~20mAor0~10V
●Multi-functioninput pointconnection
PNPtransistorconnectionmode
-+
External power supply
E
X5
X3
X4
X2
X1
PLC
+24V
Enabled external 24V power supply
COMCOM
Enabled inner 24V power supply
+24V
PLC
X1
X2
X4
X3
X5
Shield Cable E
External control signals
+24V
PLC
COM
+24V
PLC
COM
VFD VFD
External control signals
Shield Cable
NPNtransistorconnectionmode
Enabled inner 24V power supply
+24V
PLC
X1
X2
X4
X3
X5
COM
Shield Cable E
(Default short connected )
E
COM
X5
X3
X4
X2
X1
PLC
+24V
Enabled external 24V power supply
External control signals
Shield Cable
Note:
Jumper between"+24V"and"PLC" need be removed
when external 24V power supply was chosen.
External 24V power supply
+
-
+24V
PLC
COM
+24V
PLC
COM
VFD VFD
External control signals

8
Chapter 3 Keyboard layout and functions specification
●KeyboardAppearance
●Key function
Key Name Function
Menukey Entermenuwhilestandbyorrunning.Pressesthiskeytoreturnwhilemodifyparameter. While
standbyorrunning,pressfor1sectoenterconditionmonitoringinterface.
Confirm/Shift key Presstomodifyparameterwhileinmenuinterface.Press againto confirmaftermodifying;
Pressthis keyfor1 Sectoshiftdigit, andlongpresstocycle.Eachdigitflashesthreetimeto
shifttonextdigit.
Up/downkey Selectparametergroupin menuinterface.Modifyparameterinmodifystate. Modifygiven
frequency,ID givenwhileatstandbyormonitoring state(Whilegivenfrequency,PIDaresetby
keyboardand[F4.09] needsto beset.
Runkey Whilerun/stopiscontrolledby keyboard,pressthiskey, inverterforwardruns,andtheindicator
isalwayson.Whilereverse,theindicator sparks.
Stop/resetkey Machinestopsifpressitwhilerun/stopis controlledby keyboard.Itsefficiency rangeisdefined
by[F4.08]. Inverter resetsif pressit infault state(noresetif faultisnotsolved).
●Indicator Definition
Name State Meaning
Unitindicator
light
Hz Flash/On Frequencyunit
A On Currentunit
V On Voltageunit
RPM On Motorspeedunit
% Flash/On Percentunit
State
indicatorlight
RUN On Forwardrunning
RUN Flash Reverserunning
RUN Off Stop

9
Chapter 4 Function Parameter Table
Thischapterjustprovidesfunctionparametertable.SpecificationsrefertoAC200technicalmanualor inquirythe company.
“●”:Parametercanbechangedinthe runningstate.
“〇”:Parametercan’tbe changedin therunningstate.
“×”: Parametercanbe read only.
“–”:Factorysettingparameter,onlyfactorycanset.
“※”:Parameterisrelatedtothemodel.
4.1 Basic parameters
NO. Functiondescription Rangeofsettingsanddefinition Factory
default Fea
ture
Address
F00.00 Motorcontrol mode
Asynchronous motor control mode:
0:V/F control
3:High-performanceVCwithoutPG
4:High-performanceVCwith PG
Synchronous motorcontrolmode:
6:High-performanceVCwithoutPG
7:VCwithPG
Othercontrol:
8:Voltagefrequencyseparationoutput
1/2/5:Reserved
0 〇0x000
F00.01 Reserved 0x001
F00.02 Runcommandchannel 0:Keyboardcontrol
1:Terminalcontrol 2:RS485 communicationcontrol
3:Reserved 0 ●0x002
F00.03 Frequencygiven
sourcechannelA
0:Keyboardnumbergiven
1:Reserved
2:Voltage/CurrentanalogAI1 given
3:Voltage/CurrentanalogAI2 given
4:Reserved
5:Terminal pulsePULgiven
6:RS485 communication given
7:TerminalUP/DWcontrol
8: PID controlgiven
9:Program control(PLC)given
10:Optionalcard
11:Multi-stepsspeedgiven
0 ●0x003
F00.04 Frequencygiven
sourcechannelB 1 ●0x004
F00.05 FrequencychannelB
referencesource 0:Max.outputfrequencyasreferencesource
1:Setfrequencyof channelAasreferencesource 0 ●0x005
F00.06 Frequencygiven
sourceselection
0:ChannelA
1:ChannelB
2:ChannelA+ChannelB
3:ChannelA-ChannelB
4:Max. valueofChannelAandChannelB
5:Min.valueofChannelAandChannelB
0 ●0x006
F00.07 RunningCommand
Binding
LED“0”digit: keyboard commandinstruction binding
LED“00”digit: terminal command instruction binding
LED“000”digit:communicationcommandinstruction
binding
LED“0000”digit: optional card command instruction
binding
0: nobinding
1: keyboardnumbergivenfrequency
0000 ●0x007

10
2: Reserved
3: Voltage/CurrentanalogAI1given
4: Voltage/CurrentanalogAI2given
5: Reserved
6:TerminalpulsePULgiven
7:RS485 communication given
8:TerminalUP/DWcontrol
9: PIDcontrolgiven
A:Programcontrol(PLC) given
B:Optionalcard
C: Multi-stepsspeedgiven
F00.08 Keyboarddigitalsetting
frequency 0~upperlimit 50.00Hz ●0x008
F00.09 Maxfrequencyoutput upperlimit~600.00Hz 50.00Hz 〇0x009
F00.10 Upperlimitfrequency
sourceselection
0:Upperlimitfrequencydigitalgiven
1:Reserved
2:Voltage/CurrentanalogAI1 give
3:Voltage/CurrentanalogAI2 given
4:Reserved
5:Terminal pulsePULgiven
6:RS485 communication given
7:Optionalcard
0 ●0x00A
F00.11 Upperfrequencylimit
digitalsetting Lowerlimitfrequency~max frequency 50.00Hz ●0x00B
F00.12 Lowerlimitfrequency 0.00~upperlimitfrequency 0.00Hz ●0x00C
F00.13 Lowerlimitfrequency
runningmode 0:Stopoutput,enterintopauserunningstate
1:Runatlowerlimitfrequency 1 〇0x00D
F00.14 ACCtime 1 0.01~650.00s Model set
※0x00E
F00.15 DECtime1 0.01~650.00s Modelset
※0x00F
F00.16 Rotarydirection
selection
LED“0”digit: running direction takes the opposite
0:Directionunchanged
1:Directiontakestheopposite
LED“00”digit: runningdirectionprohibited
0:Forwardandreversecommandsareallowed
1:OnlyFWDcommandallowed
2:OnlyREVcommandallowed
LED“000”digit: frequency control direction selection
0:Invalid 1: Valid
LED“0000”digit:reserved
0000 〇0x010
F00.17 G/PModelSetting 0:GType 1:PType 0 ●0x011
F00.18 Reserved 0x012
F00.19 Parameterinitialization
0:No action
1:Restorefactorydefault(notrestoringmotorparameters)
2:Restorefactorydefault(restoringmotorparameters)
3:Clearmalfunctionrecords
0 〇0x013

11
Operation Control Parameters Group
NO. Functiondescription Rangeofsettingsanddefinition Factory
setting Featur
e Address
F01.00 Start-uprunningmode
0:Startbystart-upfrequency
1:DC Brakingatfirstthenstartbystart-up
frequency
2:Speedtracking,andjudgethedirection
thenstart
0 〇0x100
F01.01 Startpre-excitationtime 0.00~60.00s 0.00s 〇0x101
F01.02 Start-upfrequency 0.00~60.00Hz 0.50Hz 〇0x102
F01.03 Start-upfrequencyholdingtime 0.0~50.0s 0.0s 〇0x103
F01.04 Brakingcurrentbeforestart 0.0~150.0% 60.0% 〇0x104
F01.05 Brakingtimebeforestart 0.0~60.0s 0.0s 〇0x105
F01.06 Speedtrackingtime 0.00~60.00s 0.50s 〇0x106
F01.07 Speedtrackingdelaywhen stop 0.00~60.00s 1.00s 〇0x107
F01.08 Reserved
F01.09 Reserved
F01.10 Stopmode 0:DECstop 1:Freestop 0 ●0x10A
F01.11 DCbraking initial frequency
whenstop 0.00~50.00Hz 1.00Hz 〇0x10B
F01.12 DCbrakingcurrentwhenstop 0.0~150.0% 60.0% 0x10C
F01.13 Reserved 0x10D
F01.14 DCbrakingholdtimewhenstop 0.0~60.0s 0.0s 〇0x10E
F01.15 Stopdetectionfrequency 0.00~50.00Hz 0.50Hz ●0x10F
F01.16 ACC/DECselection
LED“0”digit:time base selection
0:max frequency
1:fixedfrequency50Hz
2:set frequency
LED“00”digit: S ACC/DEC selection
0:BeelineACC/DEC
1:S CurveACC/DEC
LED “000” digit:reserved
LED“0000” digit: reserved
0010 〇0x110
F01.17 ACCstarttimeforScurve 0.00~10.00 0.20s 〇0x111
F01.18 ACC endtimeforS curve 0.00~10.00 0.20s 〇0x112
F01.19 DECstarttimefor Scurve 0.00~10.00 0.20s 〇0x113
F01.20 DECendtimefor Scurve 0.00~10.00 0.20s 〇0x114
F01.21 ACCtime2 0.01~650.00s 10.00s ●0x115
F01.22 DECtime2 0.01~650.00s 10.00s ●0x116
F01.23 ACCtime3 0.01~650.00s 10.00s ●0x117
F01.24 DECtime3 0.01~650.00s 10.00s ●0x118
F01.25 ACCtime4 0.01~650.00s 10.00s ●0x119
F01.26 DECtime4 0.01~650.00s 10.00s ●0x11A
F01.27 DECtimeatemergencystop 0.01~650.00s 1.00s ●0x11B
F01.28 FWD&REVdeadtime 0.0~120.0s 0.0s 〇0x11C
F01.29 Zerospeedtorquefrequency
threshold 0.00~10.00Hz 0.50Hz ●0x11D
F01.30 Zerospeedtorquecoefficient 0.0~150.0% 60.0% ●0x11E

12
F01.31 Zerospeedtorqueholdingtime 0.0~6000.0s
Ifset6000.0S,alwaysholdwithouttimelimit 0 ●0x11F
F01.32-
F01.34 Reserved
F01.35 Poweroff restartaction selection 0:Invalid 1:Valid 0 〇0x123
F01.36 Poweroffrestartwaitingtime 0.00~60.00s 0.50s 〇0x124
F01.37 Reserved 0x125
F01.38 JOGrunningfrequencysetting 0.00-Maxfrequency 5.00Hz ●0x126
F01.39 JOGACCtime 0.01~650.00s 10.00s ●0x127
F01.40 JOGDECtime 0.01~650.00s 10.00s ●0x128
F01.41 Jumpfrequency1 0.00~Maxfrequency 0.00Hz ●0x129
F01.42 Jumpfrequencyrange1 0.00~Maxfrequency 0.00Hz ●0x12A
F01.43 Jumpfrequency2 0.00~Maxfrequency 0.00Hz ●0x12B
F01.44 Jumpfrequencyrange2 0.00~Maxfrequency 0.00Hz ●0x12C
Switching value terminal parameters
NO. Functiondescription Rangeofsettinganddefinition Factory
setting Featur
e Address
F02.00 Inputterminal1(X1) Refertofunctiontable4.2 1 〇0x200
F02.01 Inputterminal2(X2) Refertofunctiontable4.2 2 〇0x201
F02.02 Inputterminal3(X3) Refertofunctiontable4.2 4 〇0x202
F02.03 Inputterminal4(X4) Refertofunctiontable4.2 5 〇0x203
F02.04 Inputterminal5(X5) Refertofunctiontable4.2 6 〇0x204
F02.05 Inputterminal6(X6 expand) Refertofunctiontable4.2 0 〇0x205
F02.06 Inputterminal7(X7 expand) Refertofunctiontable4.2 0 〇0x206
F02.07 Inputterminal8(X8 expand) Refertofunctiontable4.2 0 〇0x207
F02.08 Inputterminal9(X9 expand) Refertofunctiontable4.2 0 〇0x208
F02.09 Inputterminal10(X10 expand) Refertofunctiontable4.2 0 〇0x209
F02.10 X1~X4 terminaltraitselection
0:Onvalid 1:Offvalid
LED“0”digit:X1
LED “00” digit: X2
LED“000”digit: X3
LED“0000” digit: X4
0000 ●0x20A
F02.11 X5~X8 terminaltraitselection
0:Onvalid 1:Offvalid
LED“0”digit:X5
LED “00” digit: X6
LED“000”digit: X7
LED“0000” digit: X8
0000 ●0x20B
F02.12 X9~X10terminaltraitselection
0:Onvalid 1:Offvalid
LED“0”digit:X9
LED “00” digit: X10
LED “000” digit:Reserved
LED“0000” digit: Reserved
0000 ●0x20C
F02.13 X1validdetectiondelay 0.000~6.000s 0.010 ●0x20D
F02.14 X1invalid detectiondelay 0.000~6.000s 0.010 ●0x20E
F02.15 X2validdetectiondelay 0.000~6.000s 0.010 ●0x20F
F02.16 X2invalid detectiondelay 0.000~6.000s 0.010 ●0x210
F02.17 X3validdetectiondelay 0.000~6.000s 0.010 ●0x211
F02.18 X3invalid detectiondelay 0.000~6.000s 0.010 ●0x212

13
F02.19 X4validdetectiondelay 0.000~6.000s 0.010 ●0x213
F02.20 X4invalid detectiondelay 0.000~6.000s 0.010 ●0x214
F02.21 X5validdetectiondelay 0.000~6.000s 0.010 ●0x215
F02.22 X5invalid detectiondelay 0.000~6.000s 0.010 ●0x216
F02.23 Terminalcontrolrunningmode
0:2-line1
1:2-line2
2:3-line1
3:3-line2
0 〇0x217
F02.24 Terminaloperateprotection
0:OFF 1:ON
LED “0” digit: Terminal operate
protection when abnormal exit
LED “00” digit: Jog terminal operate
protection when abnormal exit
LED “000”digit: Operate protection
when command channel switch to
terminal
0111 〇0x218
F02.25 Counterinput 0:CommonXterminal
1: High speed input terminal PUL
2:PG cardcounting 0 ●0x219
F02.26 Countinputfrequencydivision 0~6000 0 ●
0x21A
F02.27 PULsignalsource 0:X5(max~5KHz)
1:Extend interfaceX10 0 〇0x21B
F02.28 PULinputminfrequency 0.00~50.00KHz 0.00kHz ●0x21C
F02.29 PULminfrequency
correspondingsetting 0.00~100.00% 0.00% ●0x21D
F02.30 PULinputmax frequency 0.00~50.00 KHz 50.00kHz
●0x21E
F02.31 PULmaxfrequency
correspondingsetting 0.00~100.00% 100.00% ●0x21F
F02.32 PULfiltertime 0.000~9.000s 0.100s ●0x220
F02.33 PULcut-off frequency 0.000~1.000KHz 0.010kHz
●0x221
F02.34 UP/DWterminalcontrolmode 0:Offelectricitystorage
1:Offelectricitydoesnotstorage
2:Validinrunning, clearzeroat stop 0 〇0x222
F02.35 ACC/DECspeedofUP/DW
terminalfrequency control 0.01~50.00Hz/s 0.50Hz/s ●0x223
F02.36 Reserved 0x224
F02.37 Timer timeunit 0:Second 1:Minute 2:Hour 0 ●0x225
F02.38 Timersetting value 0~65000 0 ●0x226
F02.39 Countermax value 0~65000 1000 ●0x227
F02.40 Countersettingvalue 0~65000 500 ●0x228
F02.41 Reserved 0x229
F02.42 Outputterminalpolarityselection
0:Positive 1: Negative
LED“0”digit:Terminal Y
LED “00” digit: Relay output 1
LED “000” digit:Extended Y1 terminal
LED “0000” digit:Extended Relayoutput
2
0000 ●0x22A
F02.43 OutputterminalY1 Refertofunctiontable4.2 1 ●0x22B
F02.44 ExtendterminalY1 Refertofunctiontable4.2 0x22C

14
F02.45 Relay output Refer tofunctiontable4.2 4 ●0x22D
F02.46 Extendrelayoutput2 Refertofunctiontable4.2 0x22E
F02.47 Youtputdelaytime 0.000~6.000s 0.010s ●0x22F
F02.48 ExtendYoutputdelayoutput 0.000~6.000s 0.010s ●0x230
F02.49 Relay 1outputdelay time 0.000~6.000s 0.010s ●0x231
F02.50 Extendrelay2outputdelaytime 0.000~6.000s 0.010s ●0x232
F02.51 Outputfrequencylevel1(FDT1) 0.00~Max.frequency 30.00Hz ●0x233
F02.52 FDT1lag 0.00~Max.frequency 1.00Hz ●0x234
F02.53 Outputfrequencylevel2(FDT2) 0.00~Max.frequency 50.00Hz ●0x235
F02.54 FDT2lag 0.00~Max.frequency 1.00Hz ●0x236
F02.55 Givenfrequencyarriving
checkoutrange 0.00~50.00Hz 2.00Hz ●0x237
F02.60 Virtual vX1terminalfunction
selection Refertofunctiontable4.2 0 ●0x238
F02.61 Virtual vX2terminalfunction
selection Refertofunctiontable4.2 0 ●0x239
F02.62 Virtual vX3terminalfunction
selection Refertofunctiontable4.2 0 ●0x23A
F02.63 Virtual vX4terminalfunction
selection Refertofunctiontable4.2 0 ●0x23B
F02.64 vXterminalvalidstatesource
0:internalconnectionwithvirtualvYn
1:ConnectwithphysicalterminalXn
2:functioncodesettingvalidornot
LED “0”digit: virtualvX1
LED “00” digit:virtual vX2
LED “000” digit:virtual vX3
LED “0000” digit:virtual vX4
0 ●0x23C
F02.65 Virtual vXterminalfunctioncode
settingvalidstate
0:invalid 1: valid
LED “0”digit: virtualvX1
LED “00” digit:virtual vX2
LED “000” digit:virtual vX3
LED “0000” digit:virtual vX4
0 ●0x23D
F02.66 Virtual vY1terminalfunction
selection Refertofunctiontable4.2 0 ●0x23E
F02.67 Virtual vY2terminalfunction
selection Refertofunctiontable4.2 0 ●0x23F
F02.68 Virtual vY3terminalfunction
selection Refertofunctiontable4.2 0 ●0x240
F02.69 Virtual vY4terminalfunction
selection Refertofunctiontable4.2 0 ●0x241
F02.70 vY1outputdelay 0.000~6.000s 0.010 ●0x242
F02.71 vY2outputdelay 0.000~6.000s 0.010 ●0x243
F02.72 vY3outputdelay 0.000~6.000s 0.010 ●0x244
F02.73 Virtual vY2 outputselection 0.000~6.000s 0.010 ●0x245

15
AnalogTerminalParameters
NO. Functiondescription Rangeofsettingsanddefinition Factory
setting Featu
re Address
F03.00 AI1Lowerlimit 0.00~10.00V 0.00V ●0x300
F03.01 AI1Lowerlimit
correspondingsetting -100.00~100.00% 0.00% ●0x301
F03.02 AI1upperlimit 0.00~10.00V 10.00V ●0x302
F03.03 AI1upperlimit
correspondingsetting -100.00~100.00% 100.00% ●0x303
F03.04 AI1filtertime 0.000~6.000s 0.010s ●0x304
F03.05 AI1zeropointloopvoltage 0.00~10.00V 0.00V
●0x305
F03.06 AI2Lowerlimit 0.00~10.00V 0.00V ●0x306
F03.07 AI2Lowerlimit
correspondingsetting 0.00~100.00% 0.00% ●0x307
F03.08 AI2upperlimit 0.00~10.00V 10.00V ●0x308
F03.09 AI2upperlimit
correspondingsetting 0.00~100.00% 100.00% ●0x309
F03.10 AI2filtertime 0.000~6.000s 0.010s ●0x30A
F03.11 AI2zeropointloopvoltage 0.00~10.00V 0.00V
●0x30B
F03.12 AI1functionselection SeeXterminalfunction 0 〇0x30C
F03.13 AI1highlevelsetting 0.00~100.00% 70.00% ●0x30D
F03.14 AI1lowlevelsetting 0.00~100.00% 30.00% ●0x30E
F03.15 AI2functionselection SeeXterminalfunction 0 〇0x30F
F03.16 AI2highlevelsetting 0.00~100.00% 70.00% ●0x310
F03.17 AI2lowlevelsetting 0.00~100.00% 30.00% ●0x311
F03.18 Valid statesettingwhen
analogusedasterminal
0:lowlevel1:highlevel
LED“0”digit:AI1
LED “00” digit:AI2
LED“000”digit: reserved
LED“0000” digit: reserved
0000 ●0x312
F03.19 Analoginputcurve
selection
LED“0”digit:AI1
0:Beeline (default) 1:curve 1 2:curve 2
LED “00” digit: AI2 (Select voltage or current
input by wire jumper)
LED “000” digit:reserved
LED“0000”digit: reserved
0000 ●0x313
F03.20 Reserved 0x314
F03.21 Curve 1lowerlimit 0.00~10.00V 0.00V ●0x315
F03.22 Curve 1lowerlimit
correspondingsetting 0.00~100.00% 0.0% ●0x316
F03.23 Curve1inflectionpoint1
inputvoltage 0.00~10.00V 3.00V ●0x317
F03.24 Curve1inflectionpoint1
correspondingsetting 0.00~100.00% 30.00% ●0x318
F03.25 Curve1inflectionpoint2
inputvoltage 0.00~10.00V 6.00V ●0x319

16
F03.26 Curve1inflectionpoint2
correspondingsetting 0.00~100.00% 60.00% ●0x31A
F03.27 Curve1upperlimit 0.00~10.00V 10.0V ●0x31B
F03.28 Curve1upperlimit
correspondingsetting 0.00~100.00% 100.00% ●0x31C
F03.29 Curve 2lowerlimit 0.00~10.00V 0.00V ●0x31D
F03.30 Curve 2lowerlimit
correspondingsetting 0.00~100.00% 0.00% ●0x31E
F03.31 Curve2inflectionpoint1
inputvoltage 0.00~10.00V 3.00V ●0x31F
F03.32 Curve2inflectionpoint1
correspondingsetting 0.00~100.00% 30.00% ●0x320
F03.33 Curve2inflectionpoint2
inputvoltage 0.00~10.00V 6.00V ●0x321
F03.34 Curve2inflectionpoint2
correspondingsetting 0.00~100.00% 60.00% ●0x322
F03.35 Curve2upperlimit 0.00~10.00V 10.00V ●0x323
F03.36 Curve2upperlimit
correspondingsetting 0.00~100.00% 100.00% ●0x324
F03.37 A0outputsignalselection
LED“0”digit:AO1
0:0~10V
1:4.00~20.00mA
2:0.00~20.00mA
3:FMfrequencypulseoutput
LED “00” digit:A02 extended card
0:0~10V
1:4.00~20.00mA
2:0.00~20.00mA
LED “000” digit:reserved
LED0000 digit: reserved
0000 ●0x325
F03.38 A01 output selection
0:Givenfrequency
1:Outputfrequency
2:Outputcurrent
3:Inputvoltage
4:Outputvoltage
5:Machinespeed
6:Giventorque
7:Outputtorque
8:PIDgivenvalue
9:PIDfeedbackvalue10:Outputpower
11:Busvoltage
12:AI1
13:AI2
14:Reserved
15:PUL
16,17:IGBTtemperature1,2
18:RS485given
0 ●0x326
F03.39 A02extendedoutput
selection 1 ●0x327
F03.40 A01outputgain 25.0~200.0% 100.0% ●0x328
F03.41 A01analogoutputsignal
bias -10.0%~10.0% 0.0% ●0x329

17
F03.42 A01output filter 0.000~6.000s 0.010s ●0x32A
F03.43 A01FMfrequencyoutput
lowerlimit 0.00~100.00kHz 0.20kHz ●0x32B
F03.44 A02FMfrequencyoutput
upperlimit 0.00~100.00kHz 50.00kHz
●0x32C
F03.45 AO2extendoutputgain 25.0~200.0% 100.0% ●0x32D
F03.46 A02extendanalogoutput
signalbias -10.0%~10.0% 0.0% ●0x32E
F03.47 A02extendoutputfilter 0.000~6.000s 0.010s ●0x32F
F03.48-
F03.4
9
Reserved
Systemparameters
NO. Functiondescription Rangeofsettingsanddefinition Factory
setting Featu
re Address
F04.00 Parameterandkeylock
selections
0:Not locked
1:Functionparameterlocked
2:Functionparameterand keylocked(exceptfor
RUN/STOP/JOG)
3:Allfunctionparameterandkeylocked
0 ●0x400
F04.01 Userpassword 0~65535 0 ●0x401
F04.02-
F04.04 Reserved
F04.05 Parametercopy
0:Nofunction
1:Sendinverterparameterstokeyboardand
save
2:Send keyboardparameterstoinverter
Remainingvalue:nooperation
0 〇0x405
F04.06 Keyboardspecialfunction
selection
LED “0” digit:( Running command, stop/reset
command)
0:Built-in valid,externalonvalidfor stop/reset
command
1:Externalvalid,built-inonvalidfor stop/reset
command
2:All valid.Stop/resetcommandhasthe highest
priority;invalidwhenFWD/REVvalidatthesame
time
LED “00” digit: reserved
LED“000”digit: LCDkeyboardlanguage
selection
0:Chinese
1:English
0000
〇0x406
F04.07 Reserved 0x407
F04.08 STOPkeysetting
0:Non-keyboardcontrolmodeisinvalid
1:Non-keyboardcontrolmode stopsaccordingto
stop mode
2:Non-keyboardcontrolmode stopaccordingto
freestopmode
1 〇0x408

18
F04.09 UP/DOWN key selection
LED“0”digit:keyboardUN/DOWNkey
modifyselection
0:Invalid
1:Modifyfrequencysettingbykeyboardnumbers
F00.08
2:ModifyPIDgivesettingby keyboardnumbers
F11.01
LED “00” digit: power off storage selection
0:No savefrequencyafterpoweroff
1:Savefrequencyafterpoweroff
LED“000”digit: actionlimit
0:Operationstopforadjusting
1:Adjusting onlyinoperation,stopforholding
2:Adjustinginoperation,stopforclearing
0011 〇0x409
F04.10-
F04.13 Reserved
F04.14 Thedisplay contentof the
firstlinein runningstate
LED "0" and “00” digit: display the first group
00~63
LED "000"and "0000" digit: display the
secondgroup
00~63
1101 ●0x40E
F04.15 Thedisplay contentof the
firstlinein runningstate Same asabove 0402 ●0x40F
F04.16 Thedisplay contentof the
firstlineinstopstate Same asabove 1100 ●0x410
F04.17 Thedisplay contentof the
firstlineinstopstate Same asabove 0402 ●0x411
F04.18 Thedisplay contentof the
secondlineinrunning state Sameasabove 0402 ●0x412
F04.19 Thedisplay contentof the
secondlineinrunning state Sameasabove 1210 ●0x413
F04.20 Thedisplay contentof the
secondlineinstopstate Sameasabove 0402 ●0x414
F04.21 Thedisplay contentof the
secondlineinstopstate Sameasabove 1210 ●0x415
F04.22 Keyboarddisplayitem
setting
LED “0” digit: output frequency selection
0:Aimfrequency
1:Runningfrequency
LED“000”digit: powerdisplaydimension
0:Powerdisplaypercentage(%)
1:Powerdisplaykilowatt (KW)
0000 ●0x416
F04.23 Monitordisplayselection
LED“0”digit:C00.00-C00.39
0:Normal 1:Debugging
LED “00” digit: C00.40-C00.69
0:No display 1:Normaldisplay
0000 ●0x417
F04.24 Rotatespeeddisplay
coefficient 0.0~500.0% 0000
●0x418
F04.25 Powerdisplaycoefficient 0.0~500.0% 100.0% ●0x419
Other manuals for AC300 Series
1
This manual suits for next models
29
Table of contents
Other Veichi DC Drive manuals
Popular DC Drive manuals by other brands

Delta
Delta C2000 Plus Series user manual

Ebmpapst
Ebmpapst ECI-42 K1 Series Translation of original operating instructions

Lenze
Lenze L-force 9400 Mounting instructions

Magnetek Elevator
Magnetek Elevator HPV1000 AC Guide

Hydro
Hydro atos E-MI-AC Series manual

Acclaim Lighting
Acclaim Lighting Pixel Driver 400 user guide