Velbus manual VMB1DM – edition 1 – rev.1.0
3
Features::
◊Fit for light bulbs, halogen on mains and low-mains halogen in combination with a dimmable electronic
transformer.
◊Phase cut-off technology for resistive (light bulbs) and capacitive (dimmable electronic transformers) loads.
◊Phase cut-off technology for inductive loads (dimmable wound transformers).
◊Noiseless through CoolMOSIM FET.
◊Mains pollution (EMI) conform EN55015
◊Required mains voltage: 100-125V/60Hz of 220-240V/50Hz
◊Maximum load: 300W @ 230V or 150W @ 115V
◊Built-in non-resettable fuse
◊Gradual switch on or off (ca. 1.5s) will prolong the lamp’s life
◊Dimming from 0 to 100% in ca. 4 seconds
◊Manual control on the module
◊LED indicators for:
•The operation modes (slow, fast, very fast or 2 x blinking and continuously ON)
•The power voltage
•Data reception and forwarding through VELBUS
◊9 different operation modes (adjustable through ‘mode’ rotary switch):
•Moment control
•Start/stop timer
•Staircase lighting timer
•Dimmer
•Dimmer with memory function
•Multi-position dimmer
•Slow-on dimmer
•Slow-off dimmer
•Slow on-off dimmer
◊16 possible time set-ups (adjustable through hexadecimal rotary switch): moment - 5s - 10s - 15s - 30s -
1min -
2 min - 5min - 10min - 15min - 30min - 1u - 2u - 5u - 1dag - on/off
◊Controllable by connecting several push buttons in parallel.
◊Push button input debounce: 65ms.
◊Control through VELBUS.
◊Programmable without PC.
◊Easy learning process by operating the desired push buttons in the learning mode.
◊7 different control possibilities:
•Using push buttons turning on the lamp to full intensity.
•Using push buttons turning the lamp off.
•Using push buttons turning on the lamp to full intensity or turning off the lamp
•Using push buttons activating the set operation mode.
•Using push buttons increasing the lamp’s light intensity
•Using push buttons decreasing the lamp’s light intensity
•Using push buttons creating atmospheric lighting.
•Using push buttons turning on the lamp on the desired intensity.
◊Memory for 14 different push buttons/sliders per command.
◊Learned push buttons are saved ion case of a power failure.
◊Report to control modules for modifying the LED status.
◊247 possible addresses (adjustable through ‘ADDR’ rotary switch)
◊Required mains voltage: 12 ... 18VDC
◊Consumption in standby: 35mA at 18V (15mA at 16V).
◊Consumption activated relay: 50mA at 18V (30mA at 16VDC)
◊Standard DIN-rail housing (2 modules)
◊Dimensions (L x W x H): 90 x 36 x 58mm.
◊Weight : 95g