Connect the right and left
vents together
Insert the draft stopper on both
side of slots. Please note that the
smooth surface side of the
stopper should be toward the
round outlet.
Use screwdriver to take o the
screw which xed on body &
outlet
Put the whole outlet along the
body slot
Use the screw to x the
body with outlet tightly
Please assemble the air outlet before insert the unit into the hole.
Air outlet assemble steps as below:
grille
clips
Rotate the
figure 1 figure 2
swing clips to hold motor body in place(gure 1) then tighten screw to let
the clip clap onto the ceiling board(gure 2).
3. Connect
1) Precautions must be taken to avoid the back-ow of gases into the room from the open ue of gas or other fuel-
burning appliances.
2) The distance between the sides of the heater and the sides and any adjacent ceiling recessed heater shall not be
less than four times the minimum distance specied for the distance between the sides of the heater and any
building element adjacent to it.
3) The switches and other controls of the appliance should be installed so that they cannot be touched by a person
in the bath or shower.
Between the unit and thermal insulation please also keep 200mm clearance when installation.
LOCATION
POWER
MOUNTING
370mm x 202mm.
Hz