Veridian Healthcare 22-041 User manual

Remote TENS Pain
Management Solution
22-041
PLEASE READ THESE INSTRUCTIONS COMPLETELY BEFORE
USING YOUR TENS DEVICE
3-YEAR 2-YEAR
3-YEAR 2-YEAR
1-YEAR
1-YEAR
Intention for Use:
The Remote TENS Pain Management Solution is intended for temporary relief
of pain associated with sore and aching muscles due to strain from exercise
or normal household and work activities.
INSTRUCTION MANUAL • ENGLISH & ESPAÑOL

2 • ENGLISH
STOP! PLEASE ENSURE YOU HAVE ALL OF
THE FOLLOWING COMPONENTS BEFORE
USING YOUR TENS DEVICE
IF YOU ARE MISSING ANY PARTS, INCLUDING
INSERTS OR INSTRUCTION MANUALS, DO NOT
RETURN TO PLACE OF PURCHASE.
CONTACT CUSTOMER CARE AT 8663261313.
Electrical
Stimulator
Instruction Manual
Replacement
Electrode Order Form
USB Cable + Wall
Outlet Adapter
1 Oval, 1 Buttery
Electrode Pads
Storage Bag
Remote Control

ENGLISH • 3
Care and Safety Information......................................................................................... 4-11
Product Features............................................................................................................12-13
Charging the Device .....................................................................................................14-15
Preparing Your Device........................................................................................................16
Placement & Treatment......................................................................................................17
Pulse Program Descriptions........................................................................................18-19
Selecting Your Gel Pad .......................................................................................................19
Instructions for Use.......................................................................................................20-23
Caring for Electrode Pads ..................................................................................................24
Cleaning and Storage.........................................................................................................25
Troubleshooting ..................................................................................................................26
Product Specications........................................................................................................ 27
Warranty Information...................................................................................................29-29
Español............................................................................................................................. 31-58
Toll-Free Customer Care Help Line: 1-866-326-1313
Monday – Friday 8:30 a.m. – 4:30 p.m. CST
INDEX
Distributed by
Veridian Healthcare
1175 Lakeside
Gurnee, IL 60031
www.veridianhealthcare.com
Made in China
#93-1279 07/15
©2015 Veridian Healthcare, LLC

4 • ENGLISH
IMPORTANT SAFEGUARDS
WARNINGS & CAUTIONS
NOTE: Read all instructions and inserts included with this device
carefully before use. The following basic precautions are needed when
using an electrical product.
CAUTION: Failure to read and observe all precautions could result in
injury or equipment damage.
Improper care or use of your device may result in injury, damage to the
unit or ineective treatment. Following these instructions will ensure
the device’s ecacy and long life.
CONTRAINDICATIONS :
Do not use this device if you have a cardiac pacemaker, implanted
debrillator or other implanted metal or electronic device.
Do not use this device to treat undiagnosed chronic pain.
Do not use this device if you have suspected or diagnosed heart
problem.
Do not use this device if you have suspected or diagnosed epilepsy.
Do not use this device if you have a tendency to bleed internally
following an injury.
Do not use this device if you recently had surgery, or have ever had
surgery on your back.

ENGLISH • 5
IMPORTANT SAFEGUARDS
WARNINGS & CAUTIONS
Do not use this device if areas of skin lack normal sensations, such as
skin that tingles or is numb.
Do not use this device during pregnancy.
GENERAL WARNINGS PRIOR TO USE
• If you are under the care of a Physician, consult with your Physi-
cian before using this device
• Long-term eects of this device are not known
• Do not place the device on or close to your heart
• Take care when applying device close to the neck; do not place
this device on the front or sides of the neck. Severe spasm of the
muscles may occur and the contractions may be strong enough
to close the airway or cause diculty in breathing. Stimulation
over the neck could also aect hearing or blood pressure
• Do not apply stimulation across the chest because the intro-
duction of electrical current into the chest may cause rhythm
disturbances to the heart
• Do not place the device on or around your head. The eects of
stimulation of the brain are unknown

6 • ENGLISH
IMPORTANT SAFEGUARDS
WARNINGS & CAUTIONS
• Do not use this device while sleeping
• Do not use if you feel numbness
• Do not use this device in or close to water
• Use the only on normal, healthy, clean and dry skin. Do not
use on or close to open wounds or rashes, or over swollen, red,
infected or inamed skin
• Do not apply stimulation over, or in proximity to, cancerous
lesions
• Do not use the device on children or incapacitated persons
• Consult with your physician before using this device, because
the device may cause lethal rhythm disturbances to the heart in
susceptible individuals
GENERAL CAUTIONS PRIOR TO USE
• Read this manual before using this device for the rst time
• Keep this manual available whenever you use this device
• This device is intended for individual person use only
• This device is not eective for pain associated with Central Pain
Syndromes, such as headaches

ENGLISH • 7
IMPORTANT SAFEGUARDS
WARNINGS & CAUTIONS
• This device is for pain caused by muscle soreness, and should be
placed only around muscles where pain originates
• The pain may indicate that you have some other health problem.
You should know the reason and source of your pain before
using these devices. Do not solely rely on the treatment of this
device for pain
• The safety of using this device during pregnancy or birth has not
been established
• The eectiveness of this device depends greatly on a person’s
individual physical condition. It may not always be eective for
every user
• If you have had medical or physical treatment for your muscle
pain, consult with your treatment provider before using this de-
vice. You should contact your physician prior to using this device
following recent surgical procedures. Stimulation may disrupt
the healing process

8 • ENGLISH
IMPORTANT SAFEGUARDS
WARNINGS & CAUTIONS
OPERATING WARNINGS & CAUTIONS
• CONSULT WITH YOU PHYSICIAN IF YOU HAVE ANY OF THE
FOLLOWING:
• If you have suspected or diagnosed heart problem
• If you have suspected or diagnosed epilepsy
• If you have a tendency to bleed internally following an injury
• If you recently had surgery, or have ever had surgery on your
back
• If areas of skin lack normal sensations, such as skin that tingles
or is numb
• During menstruation or during pregnancy
• The unit is intended for the temporary relief of pain caused by
muscle soreness. The source or cause of the pain should be
addressed by a healthcare professional. Pain could indicate an
injury or condition that requires treatment
• Some people may feel skin irritation or experience a very sensi-
tive feeling in the skin due to electrical stimulation. If this occurs,
stop using these devices and consult your physician

ENGLISH • 9
IMPORTANT SAFEGUARDS
WARNINGS & CAUTIONS
• If skin under the pad feels irritated after using the stimulator for
a long period of time, use the stimulator for a shorter period of
time
• Minor redness at stimulation placement is a normal skin
reaction. It is not considered a skin irritation, and it will normally
disappear within 30 minutes after the electrodes are removed.
If the redness does not disappear after 30 minutes from the
removal of electrodes, do not use the stimulator again until after
the excessive redness has disappeared
• Turn o your device if the stimulation feels unpleasant or does
not provide pain relief
• Keep this device out of the reach of children.
• Use this device only with the pads and accessories recommend-
ed by the manufacturer
• Do not use this device when driving, operating machinery or
when swimming
• Before removing the Electrode Pad, be sure to turn it OFF, avoid-
ing unpleasant stimulation
• TENS is not a substitute for pain medications and other pain
management therapies

10 • ENGLISH
IMPORTANT SAFEGUARDS
WARNINGS & CAUTIONS
• TENS devices have no curative value
• TENS is a symptomatic treatment and, as such, suppresses the
sensation of pain that would otherwise serve as a protective
mechanism
• Do not use the unit while sleeping
• After each use, clean any adhesive residue left on the skin with
soap and water
• The eectiveness of stimulus therapy varies from person to
person. It may not be an eective treatment for all users
• The long-term eects of stimulus therapy are unknown
STORAGE WARNINGS & CAUTIONS
• Storage outside of stated storage temperature may result in
measurement error or device malfunction; storage environment
temperature is: 14°F – 140°F (-10°C – 60°C); humidity: 30-95%
RH
• Keep the unit out of reach of small children

ENGLISH • 11
IMPORTANT SAFEGUARDS
WARNINGS & CAUTIONS
• Do not store the device in direct sunlight, dusty or humid envi-
ronments, or extreme temperatures. Exact gures for appropri-
ate use and storage can be found in the Product Specications
section of this manual
CLEANING WARNINGS & CAUTIONS
• Never immerse the unit in water to clean as it may damage the
unit
• Follow the‘Cleaning and Maintenance’portion of this manual for
instruction on how to clean and care for your device

12 • ENGLISH
PRODUCT FEATURES
Remote Control
Digital Display (Details of the display will be
featured in the‘How to use your TENS device
section of this manual)
Mode Selector
Start/Pause Button
Intensity Level Adjustment (–/+)
Time Duration Adjustment
On/O Slide Switch
Charging Cable Port

ENGLISH • 13
PRODUCT FEATURES
Intensity Level Adjustment (–/+)
On/O Button
Power Indicator Light Snap Connection
Points
Electrical Stimulator
Snap-On Electrode
Contact Points
Oval Electrode
Pad
Buttery
Electrode Pad
Front Back

14 • ENGLISH
CHARGING THE DEVICE
This device includes a rechargeable battery in the
remote control and electrical stimulator unit as well as
a wall charger with USB cord.
Before rst use, the devices should be charged for approximately 2
hours. Subsequent charging will also take approximately 2 hours.
The Remote Control and Electrical Stimulator Unit are charged follow-
ing the same steps:
1. Connect the wide end of the USB cable to
the wall adapter.
2. Connect the smaller end to the selected
device.
3. During charging the LED light on
the wall adapter will be illuminated.
4. Each piece has a unique feature to
indicate that charging is complete,
as illustrated on the facing page.

ENGLISH • 15
NOTE:
A full charge will power
20 twenty-minute
treatment cycles at
a medium intensity
setting for the electrical
stimulator and
30 twenty-minute
treatments for the
remote control
before needing to be
recharged.
CHARGING THE DEVICE
During charging the power
indicator light will ash green.
When charging is complete the
indicator light will be solid green.
Unplug the wall charger when the
charging cycle is complete.
During charging battery
icon on the upper right of
the display will ash.
When charging is complete
the battery icon will
be solid.
Unplug the wall charger
when the charging cycle is
complete.

16 • ENGLISH
PREPARING YOUR DEVICE
It is necessary to prepare and assemble your device prior to treatment.
NOTE: Save the plastic lm discs for storage after treat-
ment to protect the pads from dirt and debris.
1. While the stimulator device is OFF (the
green power light is NOT illuminated)
carefully attach the electrode pads to
the control unit via the snap connection
points.
2. Pull gently to ensure the electrode pad is
rmly attached.
3. Carefully remove the plastic lm from the
electrode pad.
4. You are ready to apply the pad to the
aected treatment area.
Do not turn the power ON until the
device is in place on the user’s skin as
indicated in the‘Instructions for Use’
section of this manual.

ENGLISH • 17
PLACEMENT & TREATMENT
Read all warnings and cautions completely before use.
The electrode pads are applied directly to the skin. Clothing may be
worn over the device; clothing should not constrict the device and
should allow access to the control unit buttons.
Targeted treatment areas
may include:
• shoulder
• elbow
• thigh
• knee
• calf
• ankle
• back of neck
• upper back
• lower back
Never place device on
over the heart, on the
front or sides of neck or
the face.

18 • ENGLISH
P1
P2
P3
P4
P5
P6
PULSE PROGRAM DESCRIPTIONS
65
13-56
1.2
100
100
Combina-
tion P1-P5
Pulse on for 3.4 second
and o for 1.6 second
Pulse on for 20 second
and o for 1 second
Pulse on every 850
milliseconds
Pulse on for 3.6 second
and o for 1 second
Pulse on for 10 second
and o for 2.5 second
Combination of the above
Mild gate pain relief
Muscle performance
improvement with variable
pulse rate
Slow endorphin pain relief
Quick gate pain relief and
strong pulse amplitude
Quick gate pain relief
All kinds of pain relief
Pulse Rate Description Benet

ENGLISH • 19
PULSE PROGRAM DESCRIPTIONS
The programs are not specic to treatment at a
certain body location or to treat a specic ailment
or pain.
The sensations may include—massage, acupunc-
ture, tapping, scraping or a combination of the
sensations at variable durations and cycles.
Select the program that provides the best relief
for your particular ache and pain.
SELECTING YOUR GEL PAD
This device includes two sizes of gel
electrode pads. There is no functional
dierence in the pad. Select the size for
use most appropriate to the size of the
treatment area.

20 • ENGLISH
Read all warnings and cautions completely before use.
Recommended treatment time is 20-minutes; consult
your healthcare professional for a treatment cycle that
best suits your injury. Discontinue use immediately if
treatment is uncomfortable or painful.
1. Treatment area should be clean before applying the control unit.
Note that excessive skin lotion or soap residue may aect the
adhesiveness of the pad. Only use on HEALTHY skin areas with
no cuts, sores or wounds.
2. Apply the pad to the desired treatment area, taking care to
ensure the controller is comfortably within reach of your hand
for safety and control during treatment.
3. Ensure the electrode pad is smoothly applied and the gel adhe-
sive is holding the pad rmly in place on the skin.
INSTRUCTIONS FOR USE
Table of contents
Languages:
Other Veridian Healthcare Personal Care Product manuals