Veridian Healthcare TENS User manual

TENS Pain Management
Solution, Rechargeable
22-034
Please read these instructions comPletely before
using your tens device
3-YEAR 2-YEAR
3-YEAR 2-YEAR
1-YEAR
1-YEAR
Intention for Use:
The TENS Pain Management Solution is intended for temporary relief of
pain associated with sore and aching muscles due to strain from exercise or
normal household and work activities.
INSTRUCTION maNUal • ENglISh & ESpañOl

2 • ENGLISH
STOP! PLEASE ENSURE YOU HAVE ALL OF
THE FOLLOWING COMPONENTS BEFORE
USING YOUR TENS DEVICE
IF YOU ARE MISSING ANY PARTS, INCLUDING
INSERTS OR INSTRUCTION MANUALS, DO NOT
RETURN TO PLACE OF PURCHASE.
CONTACT CUSTOMER CARE AT 8663261313.
Control Unit Storage Case
Instruction Manual
Replacement Electrode
Order Form
1 Set of Gel
Electrode Pads
Wall Charger &
USB Cord

ENGLISH • 3
Care and Safety Information...................................................................... 4-11
Product Features and Symbols................................................................12-13
Charging Your Device ...................................................................................... 14
Preparing Your Device ..................................................................................... 15
Placement & Treatment.............................................................................16-17
Instructions for Use....................................................................................18-21
Cleaning and Storage...................................................................................... 22
Troubleshooting ............................................................................................... 23
Product Specications..................................................................................... 24
Warranty Information................................................................................ 25-26
Español..........................................................................................................27-52
Toll-Free Customer Care Help Line: 1-866-326-1313
Monday – Friday 8:30 a.m. – 4:30 p.m. CST
INDEX
Distributed by
Veridian Healthcare
1175 Lakeside
Gurnee, IL 60031
www.veridianhealthcare.com
Made in China
#93-1252 09/14
©2014 Veridian Healthcare, LLC

4 • ENGLISH
IMPORTANT SAFEGUARDS
WARNINGS & CAUTIONS
NOTE: Read all instructions and inserts included with this device
carefully before use. The following basic precautions are needed when
using an electrical product.
CAUTION: Failure to read and observe all precautions could result in
injury or equipment damage.
Improper care or use of your device may result in injury, damage to the
unit or ineective treatment. Following these instructions will ensure
the device’s ecacy and long life.
CONTRAINDICATIONS :
Do not use this device if you have a cardiac pacemaker, implanted
debrillator or other implanted metal or electronic device.
Do not use this device to treat undiagnosed chronic pain.
Do not use this device if you have suspected or diagnosed heart
problem.
Do not use this device if you have suspected or diagnosed epilepsy.
Do not use this device if you have a tendency to bleed internally
following an injury.
Do not use this device if you recently had surgery, or have ever had
surgery on your back.

ENGLISH • 5
IMPORTANT SAFEGUARDS
WARNINGS & CAUTIONS
Do not use this device if areas of skin lack normal sensations, such as
skin that tingles or is numb.
Do not use this device during menstruation or during pregnancy.
GENERAL WARNINGS PRIOR TO USE
• If you are under the care of a Physician, consult with your Physi-
cian before using this device
• Long-term eects of this device are not known
• Do not place the device on or close to your heart
• Take care when applying device close to the neck; do not place
this device on the front or sides of the neck. Severe spasm of the
muscles may occur and the contractions may be strong enough
to close the airway or cause diculty in breathing. Stimulation
over the neck could also aect hearing or blood pressure
• Do not apply stimulation across the chest because the intro-
duction of electrical current into the chest may cause rhythm
disturbances to the heart
• Do not place the device on or around your head. The eects of
stimulation of the brain are unknown

6 • ENGLISH
IMPORTANT SAFEGUARDS
WARNINGS & CAUTIONS
• Do not use this device while sleeping
• Do not use if you feel numbness
• Do not use this device in or close to water
• Use the only on normal, healthy, clean and dry skin. Do not
use on or close to open wounds or rashes, or over swollen, red,
infected or inamed skin
• Do not apply stimulation over, or in proximity to, cancerous
lesions
• Do not use the device on children or incapacitated persons
• Consult with your physician before using this device, because
the device may cause lethal rhythm disturbances to the heart in
susceptible individuals
GENERAL CAUTIONS PRIOR TO USE
• Read this User Manual before using this device for the rst time
• Keep this manual available whenever you use this device
• This device is intended for individual person use only
• This device is not eective for pain associated with Central Pain
Syndromes, such as headaches

ENGLISH • 7
IMPORTANT SAFEGUARDS
WARNINGS & CAUTIONS
• This device is for pain caused by muscle soreness, and should be
placed only around muscles where pain originates
• The pain may indicate that you have some other health problem.
You should know the reason and source of your pain before
using these devices. Do not solely rely on the treatment of this
device for pain
• The safety of using this device during pregnancy or birth has not
been established
• The eectiveness of this device depends greatly on a person’s
individual physical condition. It may not always be eective for
every user
• If you have had medical or physical treatment for your muscle
pain, consult with your treatment provider before using this de-
vice. You should contact your physician prior to using this device
following recent surgical procedures. Stimulation may disrupt
the healing process

8 • ENGLISH
IMPORTANT SAFEGUARDS
WARNINGS & CAUTIONS
OPERATING WARNINGS & CAUTIONS
• CONSULT WITHYOU PHYSICIAN IFYOU HAVE ANY OF THE
FOLLOWING:
• If you have suspected or diagnosed heart problem
• If you have suspected or diagnosed epilepsy
• If you have a tendency to bleed internally following an injury
• If you recently had surgery, or have ever had surgery on your
back
• If areas of skin lack normal sensations, such as skin that tingles
or is numb
• During menstruation or during pregnancy
• The unit is intended for the temporary relief of pain caused by
muscle soreness. The source or cause of the pain should be
addressed by a healthcare professional. Pain could indicate an
injury or condition that requires treatment
• Some people may feel skin irritation or experience a very sensi-
tive feeling in the skin due to electrical stimulation. If this occurs,
stop using these devices and consult your physician

ENGLISH • 9
IMPORTANT SAFEGUARDS
WARNINGS & CAUTIONS
• If skin under the pad feels irritated after using the stimulator for
a long period of time, use the stimulator for a shorter period of
time
• Minor redness at stimulation placement is a normal skin
reaction. It is not considered a skin irritation, and it will normally
disappear within 30 minutes after the electrodes are removed.
If the redness does not disappear after 30 minutes from the
removal of electrodes, do not use the stimulator again until after
the excessive redness has disappeared
• Turn o your device if the stimulation feels unpleasant or does
not provide pain relief
• Keep this device out of the reach of children.
• Use this device only with the pads and accessories recommend-
ed by the manufacturer
• Do not use this device when driving, operating machinery or
when swimming
• Before removing the Electrode Pad, be sure to turn it OFF, avoid-
ing unpleasant stimulation
• TENS is not a substitute for pain medications and other pain
management therapies

10 • ENGLISH
IMPORTANT SAFEGUARDS
WARNINGS & CAUTIONS
• TENS devices have no curative value
• TENS is a symptomatic treatment and, as such, suppresses the
sensation of pain that would otherwise serve as a protective
mechanism
• Do not use the unit while sleeping
• After each use, clean any adhesive residue left on the skin with
soap and water
• The eectiveness of stimulus therapy varies from person to
person. It may not be an eective treatment for all users
• The long-term eects of stimulus therapy are unknown
STORAGE WARNINGS & CAUTIONS
• Storage outside of stated storage temperature may result in
measurement error or device malfunction; storage environment
temperature is: 14°F – 140°F (-10°C – 60°C); humidity: 10-95%
• Keep the unit out of reach of small children

ENGLISH • 11
IMPORTANT SAFEGUARDS
WARNINGS & CAUTIONS
• Do not store the device in direct sunlight, dusty or humid envi-
ronments, or extreme temperatures. Exact gures for appropri-
ate use and storage can be found in the Product Specications
section of this manual
CLEANING WARNINGS & CAUTIONS
• Never immerse the unit in water to clean as it may damage the
unit
• Follow the‘Cleaning and Maintenance’portion of this manual for
instruction on how to clean and care for your device

12 • ENGLISH
PRODUCT FEATURES
Increase
Intensity
+
Power
Button
Decrease
Intensity
–
TENS
Control Unit
Control Unit Speaker

ENGLISH • 13
PRODUCT FEATURES
Dual Gel
Pads
Protective
Film
Gel Electrode Pads

14 • ENGLISH
CHARGING YOUR DEVICE
This device includes a rechargeable battery and wall
charger with USB cord.
Before rst use, the battery should be charged for approximately 6
hours. Subsequent charging will take approximately 2 hours.
To charge the device:
1. Flip up the outlet prongs on the wall
adapter.
2. Insert the wider USB cable end into the
power connector; insert the smaller Mini
B cable end into the TENS device.
3. While charging the red and green lights
on the wall charger will be illuminated.
4. When the device is fully charged only the
green light on the wall charger will illu-
minate; please follow the recommended
charge times as indicated above to ensure
maximum charge.
NOTE: A full charge will power 6 full treatment
cycles before needing to be recharged.

ENGLISH • 15
PREPARING YOUR DEVICE
It is necessary to prepare and assemble your device prior to treatment.
NOTE: Save the large plastic lm for storage after treat-
ment to protect the gel pads from dirt and debris.
1. Peel o the one side of the blue plastic from the gel pads.
2. The gel pads are applied to the back of
the TENS Control Unit along the curved
electrode ridges.
3. While the device is OFF (the GREEN LED
light is NOT illuminated), carefully align
the gel pads on the back side as shown
and press rmly to ensure the pads are
completely adhered to the electrode
ridges.
4. Carefully remove the plastic lm from the
electrode pads.
5. You are ready to apply the pad to the
aected treatment area.
Do not turn the power ON until the
device is in place on the user’s skin as
indicated in the‘Instructions for Use’
section of this manual.

16 • ENGLISH
PLACEMENT & TREATMENT
Read all warnings and cautions completely before use.
The electrode pads are applied directly to the skin. Clothing may be
worn over the device; clothing should not constrict the device and
should allow access to the control unit buttons.
Targeted treatment areas
may include:
• shoulder
• elbow
• thigh
• knee
• calf
• ankle
• back of neck
• upper back
• lower back
Never place device on
over the heart, on the
front or sides of neck or
the face.

ENGLISH • 17
PLACEMENT & TREATMENT
The TENS device may be placed directly on the treatment site where
you are experiencing pain.
An alternative therapy is to apply the
TENS device on alternating sides of the
location of the pain.
For example, if the treatment site is the
elbow, place the TENS unit above the
pain site for the 20 minute cycle, and
then place below the pain site for 20
minutes, surrounding the location.
X

18 • ENGLISH
Read all warnings and cautions completely before use.
Treatment time is 20-minutes. Discontinue use immedi-
ately if treatment is uncomfortable or painful.
1. Treatment area should be clean and dry before applying the
control unit. Note that excessive skin lotion or soap residue may
aect the adhesiveness of the pad. Only use on HEALTHY skin
areas with no cuts, sores or wounds.
2. Apply the control unit and pad to the desired treatment area.
3. Ensure the electrode pads are smoothly applied and the gel
adhesive is holding the pad rmly in place on the skin.
4. Press and release the POWER symbol button. A GREEN led light
will ash briey and the device will
beep to indicate the power is on.
5. The TENS unit will begin to operate
at the lowest level setting. The
default lowest level mode is a
rotation of 4 pulse types at level
1 — scraping, massage, tapping,
acupuncture.
6. Press and release the‘+’button to
INSTRUCTIONS FOR USE
POWER
On/O
+ Increase
Intensity
Level
– Decrease
Intensity Level

ENGLISH • 19
nd your desired therapy sensation level.This device oers 15
intensity levels. Press and release the ‘–’ button to reduce the
intensity level. As you press and release the button, the green
light will ash and the device will beep 1x for each intensity level
adjustment.
7. To change the mode, while the unit is on/operating, press and
hold the‘+’for 3 seconds; the mode will switch the next in the se-
quence of pulse types — scraping, massage, tapping, acupunc-
ture, or combination (all 4 types in sequence/default mode). As
you press and hold the button, the green light will illuminate 2x
and the device will beep 2x to indicate the change in mode type.
8. The sensation should be strong but comfortable; press the +or –
button at any time during the treatment to change the intensity
as desired.
9. The device will pulse for several seconds, pause and resume
repeatedly until the treatment is nished.
INSTRUCTIONS FOR USE
Until you are familiar with use of the unit, begin with
the lower intensity levels and gradually progress to
more advanced levels as you feel comfortable.

20 • ENGLISH
10. The device will automatically shut o after 20 minutes of use.
To discontinue use prior to the end of treatment time, press and
release the POWER button. The green light will ash 3x and the
device will beep 3x and the unit will power o.
Do NOT attempt to remove the device during operation.
11. Be sure the device is OFF (no sensation is felt) before removing
the device from your skin. Take care during removal to best pro-
tect the adhesive and preserve the life of the electrode pad.
12. Place the plastic cover over the gel pads to prevent them from
drying out. Store the device in the included storage case.
13. To conserve the battery and prevent shocks, the device will
automatically power o when not in use. The green light will
illuminate for three seconds, then ash three times before
shutting o.
INSTRUCTIONS FOR USE
This manual suits for next models
1
Table of contents
Languages:
Other Veridian Healthcare Personal Care Product manuals
Popular Personal Care Product manuals by other brands

HoMedics
HoMedics LT-50 Instruction manual and warranty information

Orliman
Orliman LB2800 Use and maintenance instructions

Philips
Philips DTI-2 user manual

Stealth Products
Stealth Products True Forming Back Flex Owner’s Manual and Maintenance Guide

Berenbrinker
Berenbrinker OKKLUEASY Instructions for use

medi
medi Genumedi Instructions for use