Vertiv Liebert LVC User manual

Liebert® LVC
User Manual

Copyright
The content in this document is subject to change without notice. All rights, including rights of translation,
reproduced by printing, copying or similar methods, and even of parts, are reserved. Violators will be liable for
damages. All rights, including rights deriving from patent license or registration of a utility model or design,
are reserved. No part of this document may be reproduced or transmitted in any form or by any means
without the prior written consent of Vertiv Co. Ltd.
Notice
The purchased products, services, and features are stipulated by the contract made between Vertiv Co.,
and the customer. All or part of the products, services, and features described in this document may not be
within the purchasing scope or the usage scope. Unless otherwise specied in the contract, all statements,
information, and recommendations in this document are provided “AS IS” without warranties, guarantees or
representations of any kind, either express or implied. The information in this document is subject to change
without notice. Every eort has been made in the preparation of this document to ensure the accuracy of
the contents, but all statements, information, and recommendations in this document do not constitute a
warranty of any kind, express or implied.
Vertiv Co. Ltd.
China
Website: www.vertivco.com
Email: support@Vertivco.com
Customer Service Hotline: 4008876510
Asia-Pacic
Website: www.vertivco.com
Email: overseas.support@Vertivco.com
For Technical Support, users may contact the nearest Vertiv Co. local sales oice or service center.

Purpose of the Document
This document applies to the Liebert LVC used in precision air conditioners and cooling solutions which
maintain an optimal environmental control of technological ecosystems at minimal operating costs. This
document gives an overview of the technical specication and parameters. The gures used in this document
are for reference only.
Styling used in the Guide
The styles used in this manual are dened in the following table:
Situation Description
Warning/Danger/Caution
The Warning/Danger/Caution note indicates a hazardous or potentially harmful situation
that can result in death or injury. It also indicates instructions that need to be adhered to,
failing which may result in danger and safety issues, thereby having an adverse eect on the
reliability of the device and security. Even for practices not related to physical injury, to avoid
equipment damage, performance degradetion, or interruption in service, follow the warning
instruction carefully.
Notes The Note section indicates additional and useful information, It also calls attention to best
practices and industry-best protocols that are standardized and help make maximum
utilization of the resources at hand. Helpful information related to the mainstream content
also comes under the Note heading helping the users with the denitions, concepts, and
terminologies used in the manual.
Version History
Version Revision Date Issue Changes
1.2 28-12-2018 31013644

Vertiv | Liebert LVC | User Manual i
Table of Contents
Table of Contents
Chapter 1: Product Overview.......................................................................................................................................1
1.1. Model Description.....................................................................................................................................................................................................1
1.2. Nomenclature...............................................................................................................................................................................................................2
1.3. Technical Parameters...........................................................................................................................................................................................3
1.3.1. Mechanical Parameters.......................................................................................................................................................................... 3
1.3.2. Mounting Base Dimensions..............................................................................................................................................................4
1.3.3. Parameters of Operating Environment.................................................................................................................................. 5
1.3.4. Parameters of Storage Environment........................................................................................................................................ 5
Chapter 2: Installation.........................................................................................................................................................6
2.1. Moving, Unpacking and Inspection .......................................................................................................................................................6
2.1.1. Moving.....................................................................................................................................................................................................................6
2.1.2. Unpacking ...........................................................................................................................................................................................................7
2.1.3. Inspection ..........................................................................................................................................................................................................8
2.2. Installation Notes......................................................................................................................................................................................................8
2.3. Space Requirements ..........................................................................................................................................................................................10
2.4. Installation Procedures ....................................................................................................................................................................................14
2.4.1. Installing Pipelines....................................................................................................................................................................................14
2.4.2. Connecting External Power...........................................................................................................................................................15
Chapter 3: Spray Cooling Module (Optional Component) ..........................................................18
3.1. Introduction of Spray Cooling Module.............................................................................................................................................. 18
3.2. Requirements of Spray Water Quality .............................................................................................................................................. 18
3.3. Pipe Installation of Spray Water System ....................................................................................................................................... 19
3.3.1. Water Softener ............................................................................................................................................................................................20

Vertiv | Liebert LVC | User Manual ii
Table of Contents
3.3.2. Water Filter .....................................................................................................................................................................................................21
3.4. Electrical Control Box of Spray Cooling Module ....................................................................................................................21
3.5. Pre-Commissioning (Trial running) of Spray Cooling Module ..................................................................................21
3.6. Antifreeze Maintenance of Spray Water System....................................................................................................................22
3.6.1. Antifreeze Maintenance of Spray Cooling Module.................................................................................................. 22
3.6.2. Antifreeze Maintenance of Spray Water System ..................................................................................................... 23
Chapter 4: Application of Fan Speed Controller....................................................................................24
4.1. HMI......................................................................................................................................................................................................................................24
4.1.1. RS485 Serial Communication Port...........................................................................................................................................24
4.1.2. Keys and LCD ..............................................................................................................................................................................................24
4.2. Operation Description of HMI ..................................................................................................................................................................25
4.2.1. Initial Interface ...........................................................................................................................................................................................25
4.2.2. Main Menu Interface ..........................................................................................................................................................................26
4.2.3. Analog Main Menu Interface .......................................................................................................................................................26
4.2.4. Current Alarm Main Menu Interface....................................................................................................................................26
4.2.5. Historical Alarm Main Menu Interface................................................................................................................................28
Chapter 5: Maintenance and Troubleshooting.........................................................................................29
5.1. Maintenance ............................................................................................................................................................................................................ 29
5.1.1. Maintenance of Condenser Components..........................................................................................................................29
5.1.2. Maintenance of Spray Water System.....................................................................................................................................31
5.2. Troubleshooting .....................................................................................................................................................................................................31
Appendix I: Circuit Diagram .................................................................................................35
Appendix II: Hazardous Substances..................................................................................37

Vertiv | Liebert LVC | User Manual 1
Product Overview
Chapter 1: Product Overview
1.1. Model Description
Liebert LVC is a professional equipment, which is situated in restricted area and can be accessed by authorized
personnel only. This chapter introduces the nomenclature, main components and technical parameters of the
Liebert LVC. The main component of the condenser includes heat exchanger, fan, fan speed controller and
pressure sensor. The appearance and position of the components are shown in Figure 1-1.
Figure 1-1 LVC Condenser

Vertiv | Liebert LVC | User Manual 2
Product Overview
1.2. Nomenclature
Nomenclature of the condenser is shown in Table 1-1.
Table 1-1 LVC Condenser Model Nomenclature
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
L V C 0 8 8 S E 2 N 0 P H C E 0 0 0
Digit 1,3 Product Series Digit 12 Panel Material
LVC Liebert V-Shaped Condenser P Painted Hot Dip Galvanized Steel + Aluminium
Digit 4-6 Heat Rejection Capacity kW S Stainless Steel + Anodized Aluminium
088 88 kW Digit 13 Coil Fins Anti Corrosion Class
Digit 7 Fan Quality/Sound Level 0 C2
S 2-Fan, Standard Sound H C3 & C4
L 2-Fan, Low Sound E C5
Digit 8 Control Type Digit 14 Packaging
E EC Fan Control P Packaging - Cardboard
Digit 9 Circuit / Refrigerant C Packaging - For Export
2 Two Refrigerant Circuit, R22/R407 Digit 15 Special Requirements
4 Two Refrigerant Circuit, R410A A None
Digit 10 Power Supply E For Export
3 380-415V/3ph/50Hz+N Digit 16 Order Identier
N 380-415V/3ph/50Hz/60Hz+N 0~9
T 380-415V/3ph/60Hz+N Digit 17 Order Identier
Digit 11 Energy – Saving Kit 0~9
0 None Digit 18 Order Identier
E Pump Energy Saving Module 0~9
S Spray Cooling Module
RSpray Cooling Module + Pump Energy
Saving Module

Vertiv | Liebert LVC | User Manual 3
Product Overview
1.3. Technical Parameters
1.3.1.Mechanical Parameters
The condenser structure is shown in Figure 1-2. The mechanical parameters of each model are listed in
Table 1-2.
Figure 1-2 LVC Condenser Structure
Table 1-2 Mechanical Parameters
Model Weight without Spray
(kg)
Weight
with
Spray
(kg)
Fan
Number
Dimension (mm/inch)
L H W H1
LVC088 315 355 2 2330/91.7” 1709/67.3” 1100/43.3” 1442/56.8”
LVC106 340 380 2 2330/91.7” 1709/67.3” 1100/43.3” 1442/56.8”
LVC140 415 460 2 2330/91.7” 2222/87.5” 1250/49.2” 1912/75.3”
LVC152 430 475 2 2330/91.7” 2222/87.5” 1250/49.2” 1912/75.3”
LVC170 450 495 2 2330/91.7” 2222/87.5” 1250/49.2” 1912/75.3”
• Figure 1-2 shows the serial number labels to determine system 1 and 2. There will be stickers with
serial numbers pasted on LVC condensers to identify each system.
• There is a height dierence of the condenser unit due to the dierent heights of individual fan
model.

Vertiv | Liebert LVC | User Manual 4
Product Overview
1.3.2. Mounting Base Dimensions
The mounting base is shown in Figure 1-3, and the specic mounting base dimensions of each model are
listed in Table 1-3.
Figure 1-3 Mounting Base Figure
Table 1-3 Mounting base dimensions (unit: mm/inch)
Model L W D d
LVC088 2330/91.7” 1100/43.3” 60/2.4” 80/3.2”
LVC106 2330/91.7” 1100/43.3” 60/2.4” 80/3.2”
LVC140 2330/91.7” 1250/49.2” 60/2.4” 80/3.2”
LVC152 2330/91.7” 1250/49.2” 60/2.4” 80/3.2”
LVC170 2330/91.7” 1250/49.2” 60/2.4” 80/3.2”
• It is recommended to use M12 x 4 bolts to x the mounng base to the round holes at the instal-
laon site.
• It is recommended to use rubber cushions between mounng foot and the installed base to ab-
sorb vibraon.

Vertiv | Liebert LVC | User Manual 5
Product Overview
1.3.3. Parameters of Operating Environment
Refer to Table 1-4 for parameters of operating environment
Table 1-4 Parameters of Operating Environment
Item Requirement
Installation position The standard equivalent distance between the indoor unit and the condenser is 30m.
Vertical dierence* ∆H: -5 ≤ ∆H ≤ 20m. Installation mode vertical upward mode.
Ambient Temperature Outdoor temperature -25 ~ + 45 °C. Low temperature accessories are required are
required if the temperature is between -35 °C~ + 20 °C
Operation Power 400V ± 10%, 50/60 Hz
Altitude ≤1000 m. Derating is required if the altitude exceed 1000m
Protection level Electrical control box and fan: IP55; Total unit; IPX5
Note*: - Indicates the condenser is above the indoor unit if the value is positive otherwise the value is negative.
• When the equivalent distance between the indoor unit and the condenser exceeds 30m, refer to Sec-
tion 5.4.2- Refrigerant pipe equivalent length in “Liebert PEX Series Air Conditioner Technical Manu-
al” for the requirement of the equivalent length.
• If the spray cooling module is installed in the condenser, it is advisable to drain-out water before
winter to avoid the frost cracking of spray cooling equipment.
1.3.4. Parameters of Storage Environment
Refer to Table 1-5 for parameters of storage environment
Table 1-5 Parameters of Storage Environment
Item Requirement
Storage environment Clean indoor environment with good ventilation and no dust
Ambient Temperature -40 °C~ + 70 °C
Ambient relave humidity 5%RH ~ +70%RH
Storage time Total transportation and storage time should not exceed six months, otherwise the
performance of the system need to re-calibrated.
Table of contents
Other Vertiv Industrial Equipment manuals

Vertiv
Vertiv Liebert XDU 060 Installation and maintenance instructions

Vertiv
Vertiv Liebert DCD35 Installation and maintenance instructions

Vertiv
Vertiv XTE 401 Series User manual

Vertiv
Vertiv Liebert MicroPOD 230V Installation and maintenance instructions

Vertiv
Vertiv Liebert DA250 Installation and maintenance instructions

Vertiv
Vertiv Liebert iCOM Installation and maintenance instructions

Vertiv
Vertiv Liebert MCV Series Installation and maintenance instructions

Vertiv
Vertiv DCD Series User manual

Vertiv
Vertiv Liebert DSE Packaged Series Installation and maintenance instructions