manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. VIAIR
  6. •
  7. Other
  8. •
  9. VIAIR 91050 User manual

VIAIR 91050 User manual

IMPORTANT:
It is essential that you and any other operator of this
product read and understand the contents of this manual
before installing and using this product.
SAVE THIS MANUAL FOR FUTURE REFERENCE
USER MANUAL
5.0 GALLON AIR TANKS
PART NO. 91050
5.0 GALLON AIR TANK
Please read this instruction manual carefully prior to operating this product.
Pay particular attention to the CAUTION and WARNING statements in this manual.
Failure to comply with these instructions could result in personal injury or property
damage. Retain these instructions for future reference.
USER MANUAL
NOTE: Your air tank comes with two 1/4” NPT ports and two 3/8” NPT port openings to allow
installation in many congurations on your vehicle. To ensure safe and trouble-free use of your air
tank, we strongly recommend that you install a drain cock and a safety pressure relief valve.
IMPORTANT:
a. VIAIR tanks are rated for 150 PSI maximum working pressure. Do not over pressurize.
Overpressuring may result in death or serious injury.
b. Tank is not intended to be used as a breathing device.
c. Always wear ANSI-approved safety glasses when operating air tank.
d. Bleed pressure from tank after each use and before servicing or adding attachments.
e. Use only attachments rated for 150 PSI maximum.
CAUTION: DO NOT PRESSURIZE YOUR TANK UNTIL YOU HAVE INSTALLED ALL NECESSARY
PORT FITTINGS AND ACCESSORIES.
a. Apply sealant to threads of ttings prior to assembly and hand tighten each part then use a
wrench for an airtight connection.
b. Do not over tighten if your port ttings are made from brass, since brass threads can be stripped.
The ttings need to be only airtight.
c. Always release air from tank before servicing or repairs.
d. Wear safety glasses or goggles when operating this product.
WARNING: DRAIN TANK AFTER EACH USE. FAILURE TO DRAIN TANK AND REMOVE
CONDENSATION WILL CAUSE TANK TO RUST PREMATURELY.
a. To remove any accumulated condensation inside the tank, bleed pressure from tank until
pressure is approximately 5 PSI to 20 PSI.
b. Drain water from tank by opening the drain cock valve.
c. If drain cock valve is plugged, release all air pressure from the tank. Remove and clean the drain
cock valve then reinstall.
d. After water has been drained, close drain cock.
IMPORTANT: Please observe air tank’s Date of Manufacture (stamped on tank leg). Replace air
tank 2 to 5 years from date air tank was rst used, or use the date of manufacture as reference.
Your adherence to air tank draining guidelines will determine the replacement date of your air tank.
RUSTED TANKS CAN CAUSE EXPLOSION OR FATAL INJURY. Discard tank immediately if tank is
rusted internally.
NOTE: When using safety pressure relief valve, point the safety pressure relief valve away from your
body. Use the pull ring on the safety relief valve to open the relief valve to vent any pressure inside
the tank before attempting to service tank.
5.0 GALLON AIR TANK
USER MANUAL
Tank loses air pressure 1. Air leaks from ttings 1. Locate leak by applying soap
& water solution. Tighten
ttings as needed
Tank leaks 1. Pinhole from internal rusting
of tank
1. Replace tank immediately
Can’t get air from tank to
inate tire
1. Low tank pressure 1. Tank pressure must exceed tire
pressure. Increase tank
pressure
TROUBLESHOOTING GUIDE:
PROBLEM: POSSIBLE CAUSE(S) CORRECTIVE ACTION
5.0 GALLON AIR TANK PARTS LIST:
A.
B.
C.
D.
E.
F.
Vibration Isolators (4 pcs)
Brass Inserts (4 pcs)
Mounting Bolts (M11 x 35mm) (4 pcs)
Washers (4 pcs)
Locking Washers (4 pcs)
Hex Nuts (4 pcs)
A B CD E F
See Fig. 1 for Mounting Hardware Assembly
Fig. 1
F
E
D
C
LIMITED WARRANTY:
VIAIR Corporation warrants this product, when properly installed and under normal conditions of use, to be free from defects in
workmanship and materials for a period of one year from its original date of purchase. To receive warranty service or repair, please
contact VIAIR Corporation.
Returns should be made within one year of the date of purchase, after a Return Goods Authorization (RGA) number has been
assigned by VIAIR Corporation. To obtain RGA, fax a copy of your receipt to (949) 585-0188. For complete warranty details, please
visit: www.viaircorp.com/warranty
PLEASE NOTE:
THIS WARRANTY COVERS PRODUCT DEFECTS ONLY; IT DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES
AS RESULT OF MISUSE OR ABUSE.
This Manual is proprietary to VIAIR Corporation and no ownership rights are hereby transferred. No part of the Manual shall be
used, reproduced, translated, converted, adapted, stored in a retrieval system, communicated or transmitted by any means, for any
commercial purpose, including without limitation, sale, resale, license, rental or lease, without the prior express written consent of VIAIR.
VIAIR does not make any representations, warranties or guarantees, express or implied, as to the accuracy or completeness of the
Manual. Users must be aware that updates and amendments will be made from time to time to the Manual. It is the user’s responsibility
to determine whether there have been any such updates or amendments. Neither VIAIR nor any of its directors, ofcers, employees
or agents shall be liable in contract, tort or in any other manner whatsoever to any person for any loss, damage, injury, liability, cost or
expense of any nature, including without limitation incidental, special, direct or consequential damages arising out of or in connection
with the use of the Manual.
15 EDELMAN • IRVINE, CA 92618
TEL: (949) 585-0011 • FAX: (949) 585-0188
www.viaircorp.com

Popular Other manuals by other brands

NEC SCHMIDT PROMOTION NEWS RELEASE FINAL manual

NEC

NEC SCHMIDT PROMOTION NEWS RELEASE FINAL manual

paasche FP-1/32 OPERATING INSTRUCTIONS & REPLACEMENT PARTS

paasche

paasche FP-1/32 OPERATING INSTRUCTIONS & REPLACEMENT PARTS

Smart Control & Sensing iLOG Quick manual

Smart Control & Sensing

Smart Control & Sensing iLOG Quick manual

Nokia 6021 - Cell Phone 3.3 MB Service manual

Nokia

Nokia 6021 - Cell Phone 3.3 MB Service manual

Arcam fmj UDP411 Handbook

Arcam

Arcam fmj UDP411 Handbook

Akron Style 3443 Mercury Quick Attack Operating & maintenance instructions

Akron

Akron Style 3443 Mercury Quick Attack Operating & maintenance instructions

WWC C5 Vararam instructions

WWC

WWC C5 Vararam instructions

Vorsprung Smashpot installation instructions

Vorsprung

Vorsprung Smashpot installation instructions

Louet Delta Instructions for assembly

Louet

Louet Delta Instructions for assembly

NEC E655 user manual

NEC

NEC E655 user manual

SciCan Hydrim C61wd G4 Operator's manual

SciCan

SciCan Hydrim C61wd G4 Operator's manual

BoolahBoards BoardBrake quick guide

BoolahBoards

BoolahBoards BoardBrake quick guide

Safe SafeGate Extending Basic user manual

Safe

Safe SafeGate Extending Basic user manual

Newall DP500 quick start guide

Newall

Newall DP500 quick start guide

First Alert FA120C user manual

First Alert

First Alert FA120C user manual

Next Hydraulics MAXISTAB Installation instructions, use and maintenance manual

Next Hydraulics

Next Hydraulics MAXISTAB Installation instructions, use and maintenance manual

Electrolux EDC 66150W user manual

Electrolux

Electrolux EDC 66150W user manual

GOLDEN STATE INTERNATIONAL 40-199 manual

GOLDEN STATE INTERNATIONAL

GOLDEN STATE INTERNATIONAL 40-199 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.