VIAVI//Public
T-BERD/MTS 5800 Portable Network Tester
T-BERD/MTS-5800 Portable Network Tester
QUICK CARD
3
RUN TEST
1. Using drop-down menus , select
“Payload/BERT” for the right results display.
2. Select the Laser tab in the Actions panel,
and press . The button will turn yellow
and be relabeled .
3. Press the Restart soft key .
4. Verify the following:
►Level (dBm) is within the Rx Level range
of the SFP.
►Summary LED is green.
►Signal Present LED is green.
►Frame Sync LED is green.
►Path Pointer Present LED is green
►Pattern Sync LED is green.
►Summary/Status results shows ‘ALL
SUMMARY RESULTS OK”
5. Allow the test to run for desired duration and
verify the following:
►Bit/TSE Error Rate result does not
exceed your required threshold.
(0.00E+00 if pass/fail threshold unknown)
CONNECT TO LINE UNDER TEST
•Use the VIAVI P5000i or FiberChek Probe
microscope to inspect both sides of every
connection being used (SFP, attenuators, patch
cables, bulkheads)
►Focus fiber on the screen.
►If it appears dirty, clean the fiber end-face
and re-inspect.
►If it appears clean, run inspection test.
►If it fails, clean the fiber and re-run inspection
test. Repeat until it passes.
•If necessary, insert optical attenuators into the
SFP TX and/or RX ports.
•Connect the SFP to the port under test using a
jumper cable compatible with the line under test.
Figure 9: Results, Payload BERT
Figure 8: Inspect Before You Connect
Status Tip
Signal Present LED
not green
Check your cables. Tx and Rx may be
reversed.
Path Pointer Present
LED not green
and AIS-P alarm on
There may be no loop or no connectivity to
the loop. The wrong payload may be
selected (concatenated vs. channelized).
RDI-L alarm on
The Tx Level is too high.
Add an attenuator between the SFP Tx port
and the line under test.
Path Pointer
Adjustments incrementing
Clock Source is set incorrectly.
Change Clock Source to “Recovered.”
Figure 10: Troubleshooting Tips