VIAVI//Public
T-BERD/MTS 5800 Portable Network Tester
T-BERD/MTS-5800 Portable Network Tester
QUICK CARD
3
RUN TEST
1. Using drop-down menus , select
“Interface/Signal” for the right results display.
2. Press the Restart soft key .
3. Verify the following:
►Summary LED is green.
►Signal Present LED is green.
If the LED is red, check your cables.
Tx and Rx may be reversed.
►Frame Sync LED is green.
►RX Frequency (Hz)
= 44736000 +/- 895 Hz.
4. Using drop-down menus , select
“Payload/BERT” for the right results display.
5. Allow the test to run for desired duration and
verify the following:
►Pattern Sync LED is green.
►Bit/TSE Error Rate result does not
exceed your required threshold.
(0.00E+00 if pass/fail threshold unknown)
Figure 10: Results, Interface/Signal
CONNECT TO LINE UNDER TEST
•T-BERD 5811AND T-BERD 5822 mainframes
have BNC ports for DS3 testing. You may use
BNC to BNC or BNC to WECO cables to
connect the T-BERD to the line under test.
•T-BERD 5882 and T-BERD 5800-100G
mainframes have mini-BNC ports for DS3
testing. CB-MINITOBNCQTY1 adapters are
required to adapt to a standard BNC connector.
You may use BNC to BNC or BNC to WECO
cables to connect the adapter to the line under
test.
Figure 11: Results, Payload BERT
Figure 8: BNC Connectors
Figure 9: Mini-BNC Connectors