manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. VIAVI Solutions
  6. •
  7. Test Equipment
  8. •
  9. VIAVI Solutions T-BERD User manual

VIAVI Solutions T-BERD User manual

This manual suits for next models

1

Other VIAVI Solutions Test Equipment manuals

VIAVI Solutions T-BERD User manual

VIAVI Solutions

VIAVI Solutions T-BERD User manual

VIAVI Solutions T-BERD User manual

VIAVI Solutions

VIAVI Solutions T-BERD User manual

VIAVI Solutions T-BERD User manual

VIAVI Solutions

VIAVI Solutions T-BERD User manual

VIAVI Solutions T-BERD/MTS 5800 User manual

VIAVI Solutions

VIAVI Solutions T-BERD/MTS 5800 User manual

VIAVI Solutions T-BERD User manual

VIAVI Solutions

VIAVI Solutions T-BERD User manual

VIAVI Solutions T-BERD User manual

VIAVI Solutions

VIAVI Solutions T-BERD User manual

VIAVI Solutions T-BERD/MTS-4000 User manual

VIAVI Solutions

VIAVI Solutions T-BERD/MTS-4000 User manual

Popular Test Equipment manuals by other brands

Ambit P.F. Series instruction manual

Ambit

Ambit P.F. Series instruction manual

Megger BMM500 Series user guide

Megger

Megger BMM500 Series user guide

RJG Lynx Sensor Tester operating instructions

RJG

RJG Lynx Sensor Tester operating instructions

Mark-10 TT02 Series user guide

Mark-10

Mark-10 TT02 Series user guide

Martel 3001 Operator's manual

Martel

Martel 3001 Operator's manual

ElproSys DiagProg4 instruction manual

ElproSys

ElproSys DiagProg4 instruction manual

Redtech TRAILERteck T05 user manual

Redtech

Redtech TRAILERteck T05 user manual

Venmar AVS Constructo 1.0 HRV user guide

Venmar

Venmar AVS Constructo 1.0 HRV user guide

Test Instrument Solutions SafetyPAT operating manual

Test Instrument Solutions

Test Instrument Solutions SafetyPAT operating manual

Hanna Instruments HI 38078 instruction manual

Hanna Instruments

Hanna Instruments HI 38078 instruction manual

Kistler 5495C Series instruction manual

Kistler

Kistler 5495C Series instruction manual

Waygate Technologies DM5E Basic quick start guide

Waygate Technologies

Waygate Technologies DM5E Basic quick start guide

StoneL DeviceNet CK464002A manual

StoneL

StoneL DeviceNet CK464002A manual

Seica RAPID 220 Site preparation guide

Seica

Seica RAPID 220 Site preparation guide

Kingfisher KI7400 Series Training manual

Kingfisher

Kingfisher KI7400 Series Training manual

Kurth Electronic CCTS-03 operating manual

Kurth Electronic

Kurth Electronic CCTS-03 operating manual

SMART KANAAD SBT XTREME 3G Series user manual

SMART

SMART KANAAD SBT XTREME 3G Series user manual

Agilent Technologies BERT Serial Getting started

Agilent Technologies

Agilent Technologies BERT Serial Getting started

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

VIAVI//Public
T-BERD/MTS 5800 Portable Network Tester
T-BERD/MTS-5800 Portable Network Tester
QUICK CARD
Ethernet Layer 2 Traffic Loopback
This quick card describes how to set the T-BERD/MTS 5800 up as a Layer 2 Loopback
device.
•T-BERD/MTS 5800 equipped with the following:
oBERT software release V30.1.0 or greater
oC510M1GE test option for 10 Megabit to 1 Gigabit Ethernet
loopback
oC510GELAN test option for 10 Gigabit Ethernet loopback
oC525GE test option for 25 Gigabit Ethernet loopback
oC540GE test option for 40 Gigabit Ethernet loopback
oC550GE test option for 50 Gigabit Ethernet loopback
oC5100GE test option for 100 Gigabit Ethernet loopback
•Optical Transceiver supporting the line rate to be tested
(SFP or QSFP)
•Cables to match the optical transceiver and the line under test
•Fiber optic inspection microscope (P5000i or FiberChek Probe)
•Fiber optic cleaning supplies Figure 1: Equipment Requirements
LAUNCH TEST
1. Press the Power button to turn on the
T-BERD.
2. Press the Test icon at the top of the
screen to display the Launch Screen.
3. Using the Select Test menu, Quick Launch
menu, or Job Manager, launch the Ethernet
Layer 2 Traffic test on Port 1 for the desired
data rate. For example:
Ethernet ►1GigE Optical ►Layer 2 Traffic
►P1 Terminate.
4. Tap to open the Tools Panel and
select .
5. Press to continue.
Figure 2: Launch Screen
Figure 3: Tools Panel
VIAVI//Public
T-BERD/MTS 5800 Portable Network Tester
T-BERD/MTS-5800 Portable Network Tester
QUICK CARD
2
►The followingInformation is needed to
configure the test:
•Physical Interface (10/100/1000BASE-T,
1000BASE-LX, 10GBASE-LR, 100GBASE-LR4,
etc.)
•Auto Negotiation settings of the port
under test.
►For Optical Interfaces:
1. Press the Setup soft key on the
top right side of the screen.
2. Select the Interface/Connector folder.
3. Insert desired Optical Transceiver into
the Port 1 SFP or QSFP slot on the top
of the T-BERD.
4. Review SFP information in the
Connector tab:
oVerify that the SFP operates on the
required wavelength
(850nm, 1310nm or 1550nm).
oVerify that the SFP supports the
required data rate (1G, 10G LAN,
etc).
oNote the Min and Max Tx Levels
(dBm) and Max Rx Level (dBm) to
assess if optical attenuators are
required.
oPress the Results soft key to
return to the Test Results screen.
►For 10/100/1000 Electrical and 1GigE
Optical tests, tap the Ethernet tab of the
Quick Configuration menu and set
Auto Neg. to the same value as the Ethernet
port under test (On or Off).
Figure 4: Work Order
CONFIGURE TEST
Figure 6: Quick Config, Auto Neg.
Figure 5: Setup, Interface/Connector
VIAVI//Public
T-BERD/MTS 5800 Portable Network Tester
T-BERD/MTS-5800 Portable Network Tester
QUICK CARD
3
►For Optical Interfaces:
1. Use the VIAVI P5000i or FiberChek Probe
microscope to inspect both sides of every
connection being used (SFP, attenuators,
patch cables, bulkheads)
oFocus the fiber on the screen.
oIf it appears dirty, clean the fiber end-face
and re-inspect.
oIf it appears clean, run the inspection test.
oIf it fails, clean the fiber and re-run
inspection test. Repeat until it passes.
2. If necessary, insert optical attenuators into
the SFP TX and/or RX ports.
3. Connect the SFP to the port under test
using a jumper cable compatible with the
line under test.
4. Select the Laser tab in the Actions panel.
5. Press . The button will turn yellow
and be relabeled .
6. Press the Restart soft key .
7. Verify the following:
oSummary LED is yellow.
oSignal Present LED is green.
oSync Acquired LED is green.
oLink Active LED is green.
►For Copper 10/100/1000BASE-T interfaces:
1. Connect the 10/100/1000 RJ-45 jack to
the port under test using CAT 5E or better
cable.
2. Press the Restart soft key .
3. Verify the following:
oSummary LED is yellow.
oSync Acquired LED is green.
oLink Active LED is green.
Figure 8: Optical Interface Results
Figure 7: Inspect Before You Connect
CONNECT TO LINE UNDER TEST
Figure 9: Copper Interface Results
VIAVI//Public
T-BERD/MTS 5800 Portable Network Tester
T-BERD/MTS-5800 Portable Network Tester
QUICK CARD
© 2022 VIAVI Solutions, Inc,
Product specifications and descriptions in this
document are subject to change without notice.
Patented as described at viavisolutions.com/patents
Contact Us
To reach the VIAVI office nearest you,
visit viavisolutions.com/contact
+1 844 GO VIAVI
(+1 844 468-4284)
LOOP UP
The T-BERD may be looped up by any of the
followingmethods. Once looped, the T-BERD will
reflect all received test packet after inverting
Source and Destination MAC addresses.
1. Broadcast Loop up message: The T-BERD
will respond to VIAVI Loop up messages
received via Broadcast MAC address and enter
Local Loopback (LLB) mode.
2. Unicast Loop up message:
►The T-BERD will respond to VIAVI Loop
up messages received via Unicast MAC
address and enter LLB mode.
3. Manual Local Loopback:
►Select the Actions Panel and tap
to manually enter LLB mode.
►Tap again to exit LLB mode
when the test is complete.
With Unicast and Manual loopback, the operator
of T-BERD traffic generator will need to know the
MAC address of this T-BERD:
►Tap the Setup soft key , select the
Ethernet menu, and tap
to displaythe Factory Default Source
MAC Address of your T-BERD.
►Provide this address to the operator of the
T-BERD Traffic Generator, upon request.
►Press the Results soft key to view
the progress of the test.
Figure 12: Ethernet Setup, Source MAC
Figure 11: Manual LLB
Figure 10: Loop Up message response