INTRODUCTION
VIDI-AC-1C is a compact, waterproof stand-alone programmable access control system that provides
proximity entry for up to 2000 users. It uses Atmel microcontroller assures maximum performance in any
environment, and the low-power circuit makes its service life prolonged.
The product unique feature is simple in design, easy operation, and high reliability.
Features
Waterproof, conform to IP66
Read 125KHz EM&HID card
One programmable relay operation
Pulse mode, Latch mode
Remote infrared programmer
2000 users
Card block enrolment
Tri-colour LED status display
Built in light dependent resistor (LDR) for anti tamper
Buzzer for audible or silent mode
Low temperature resistance (-40℃)
Specifications:
User Capacity
Card
2000
EM card
Operating Voltage
Idle Current
9~18V DC
<40mA
Proximity Card Reader
Radio Technology
Read Range
EM
125KHz Proximity Card
3-10cm
Wiring Connections
Relay Output, Exit Button
Relay
Adjustable Relay Output Time
Lock Output Load
One (NO, NC, Common)
1-99 Seconds (5 seconds default)
2 Amp Maximum
Environment
Operating Temperature
Operating Humidity
Meets IP66
-40℃~60℃
20%RH-98%RH
Physical
Colour
Dimensions
Unit Weight
Shipping Weight
ABS Shell
Black
L103* W48 * H20 (mm)
100g
150g

Carton Inventory
INSTALLATION
Remove the back cover from the unit
Drill 2 holes(A,C) on the wall for the screws and one hole for the cable
Knock the supplied rubber bungs to the screw holes(A,C)
Fix the back cover firmly on the wall with 4 flat head screws
Thread the cable through the cable hole(B)
Attach the unit to the back cover
Wiring
Colour
Function
Notes
Red
Power +
9~18 Votes DC Regulated Power Input
Black
GND
Ground
White
NO
Normally Open Relay Output
Brown
COM
Common Connection for Relay Output
Green
NC
Normally closed Relay Output
Yellow
OPEN
Request to Exit input(REX)

Connection Diagram
Common power supply:
Attention: Install a 1N4004 or equivalent diode is needed when use a common power supply, or the
reader might be damaged. (1N4004 is included in the packing)
Access Control Power Supply:

PROGRAMMING
Programming will vary depending on access confirguration. Follow the instructions according to your
access configuration.
General Programming Information
Remote Control: Please use the Infrared Remote Control to program the Reader.
User ID number:Assign a user ID to the access card in order to track it. The user ID number can be
any number from 1~2000.
IMPORTANT: User IDs do not have to be proceeded with any leading zeros. Recording of User ID is
crical. Modifications to the user require the User ID be available.
Proximity Card: Any 125KHz industry standard 26 bit EM Proximity card or Tag.
Enter and Exit Program mode
Set Master Code
Programming Step
Keystroke Combination
1. Enter Program Mode
*(Master Code) #
2. Update Master Code
0(New Master Code)#(Repeat New
Master Code)#
3. Exit Program Mode
*
Add User Cards
Programming Step
Keystroke Combination
1. Enter Program Mode
*(Master Code) #
2. Add Card: Using Auto ID
(Allows device to assign Card to next
available User ID number)
OR
2. Add Card: Select Specific ID
(Allows manager to define a specific
User ID to associate the card to)
OR
2. Add Card: by Card Number
OR
2. Add Card: Block Enrollment
(Allows manager to add up to 2000
cards to the Reader in a single step.)
Takes 3 minutes to program.
1 (Read Card) #
The cards can be added continuously.
1 (User ID) # (Read Card) #
The user ID is any number from 1-2000.
1 (Input 8/10 digits Card number) #
1 ( User ID number) # (Card quantity)
#(The first card number) #
Cards’ number must be consecutive;
Card quantity is the number of card to be
enrolled.
3. Exit
*
Delete User Cards
Programming Step
Keystroke Combination
1. Enter Program Mode
*(Master Code) #
2. Delete Card: By reading card
2 (Read Card) #
Programming Step
Keystroke Combination
Enter Program Mode
* (Master Code) #
Factory default is 123456
Exit Program Mode
*

OR
2. Delete Card: Select Specific ID
OR
2. Delete Card: by Card Number
The cards can be deleted continuously.
2 (User ID) #
The user ID is any number from 1-2000.
2 (Input 8/10 digits Card number) #
Set Relay Configuration
The relay configuration sets the behaviour of the output relay on activation.
Programming Step
Keystroke Combination
1. Enter Program Mode
*(Master Code) #
2. Pulse Mode
OR
2. Latch Mode
3 (1-99) #
The relay time is 1-99 seconds.
(1 is 50mS.) Default is 5S.
3 0 #
Sets the relay to ON/OFF Latch mode
3. Exit
*
Set Strike-out Alarm
The strike-out alarm will engage after 10 failed card attempts. Factory is OFF. The strike-out alarm ca be
set to deny access for 10 minutes after engaging or it can be set disengage only after entering a valid card
or Master code.
Programming Step
Keystroke Combination
1. Enter Program Mode
*(Master Code) #
2. Strike-Out OFF
OR
2. Strike-Out ON
OR
2. Strike-Out ON (Alarm)
Set alarm time
4 0 # (factory default)
4 1 # Access will be denied for 10
minutes
4 2 #
5 (0 ~ 30) #, factory default is 1 minute
Enter Master code # or valid user card to
silence
3. Exit
*
Set Audible and Visual Response
Programming Step
Keystroke Combination
1. Enter Program Mode
*(Master Code) #
2. Control LED
OR
2. Control Sounds
OFF = 6 1 #
OFF = 6 3 #
ON = 6 2 #
ON = 6 4 #
(Factory defaults are
ON)
3. Exit
*

Others
Users Operation:
Open the door: Read the valiad user card, the door will open.
Remove Alarm: Read valid user card, or Input Master code #
Reset to Factory Default:
To reset to factory default, power off, press the Exit Button, hold it and power on, there will be two beeps,
and the LED light turns into yellow, release the Exit Button, then read any two 125KHz EM card, the LED
turn into red, mean reset to factory default successfully. Of the two cards reading, the first one is Master
Add Card, and the second one is Master Delete Card.
Remarks: Reset to factory default, the user’s information is still retained.
Erase all Cards
This will delete ALL User data.
1, Enter Program Mode by press: *(Master Code) #.
2, Press 2 and Master code again
3, Exit: *
All configuration data is retained.
Sound and Light indication
Operation Status
LED
Buzzer
Stand by
Red light bright
-
Enter into programming mode
Red light shines
One beep
In the programming mode
Yellow light bright
One beep
Operation error
-
Three beeps
Exit from the programming mode
Red light bright
One beep
Open lock
Green light bright
One beep
Alarm
Red light Shines quickly
Beeps

Simplified Instruction
Function description Operation
Enter the programming mode
*- 123456 - #
then you can do the programming
(123456 is the default factory master code)
Change the master code
0 - new code - # - repeat the new code - #
(code: 6 digits)
Add card user
1- Read Card - #
(can add Cards continuously)
Delete card user
2 - Read Card -#
(can delete Cards continuously)
Exit from the programming mode
*
How do release the door
Card User
Read card
Table of contents