Check the transmitter is vertical on the tank.
Check positioning of the transmitter (ensure the transmitter is not too close to
the tank sides or internal obstructions).
Ensure that the transmitter is not too tightly attached to the tank.
Ensure that the tank is not overfilled and that the bottom of the transmitter is
clean.
Received
reading is
inconsistent
EO1
Reading not
received after
6 hours
E02
Reading
received but
void
E03
Received
Reading
greater than
tank height
E04
Contact
Vendor
EO5
Contact
Vendor
EO6
Error Description To Rectify :
Check the transmitter is within range of the monitor.Try and relocate the
monitor to a position that is nearer a window,remember that the transmitter
communicates with the monitor by use of an FM signaland moving the
monitor plug from possible metalobstructions can improve the signal.
Check that there are no metal obstruction that may deflect the signal.
Ensure the monitor is not too close to,or obstructed by,other electrical
appliances.
Check positioning of the transmitter (ensure the transmitter is not too close to
the tank sides or internal obstructions).
Ensure that the transmitter is not too tightly attached to the tank.
Ensure that the tank is not overfilled i.e.thereisaminimumof 4 inches
free space between the transmitter and level.
Ensure the bottom of sensor is clean.
Check the tank height and ensure this information is correct on the monitor,
press the 6.andV keys together to view your tank configuration.If height is
incorrect,enter the setup mode by pressing SETUP for thre seconds,
press ENTER until you reach screen 5 and adjust the height using 6.andV keys.
Press ENTER to save.Press SETUP to exit Setup mode.Wait 3 hours for updated
readings.
Check the transmitter is vertical and the positioning of the transmitter (ensure
the transmitter is not too close to the tank sides or internal obstructions).
This is a hardware fault please contact your distributor
This is a hardware fault please contact your distributor