ViewSonic Manual
1. INTRODUCTION
The ViewSonic Sensor is a battery operated ultrasonic liquid
level sensor that is capable of providing the user with instant
level indication at a glance. The ViewSonic Transmitter uses
ultrasonic (sound wave) technology to measure the distance
from the sensor face to the surface of the liquid in chemical
tank or sump, then back to sensor face; this is referred to as
(time of flight) As the liquid product inside the tank decreases
the distance that the senor measures increases accordingly.
The current level measurement can be viewed directly on the
LCD screen located on the sensor or via the remote display.
No wiring is required as the level data is wirelessly
transmitted to the remote display.
Gallons / Inches / %
After completion of programming the display calculates and
displays the amount of liquid remaining in your tank in
gallons, inches or as a percentage of the tank capacity. In
addition
Mounting
The ViewSonic sensor can be mounted directly on the top of
the tank, drum, tote and is suitable for use with any plastic
or metal tank up to 10'(3m) in height, including double
walled tanks.
Easy to Install
01
www.iconprocon.com
ViewSonic
User Manual
ROOM TEMPERATURE
FULL
LIQUID LEVEL
EMPTY
2O
°F
65O
Gal

1
2
3
4
5
6
7
8
9
10
11
12
13
LCD Display
MODE key
DOWN key
ENTER key
UP Key
SETUP Key
Alarm Red LED
ViewSonic Sensor
Self-tapping screws x 2
Weatherseal (Gasket)
Installation Fitting 2" , 1 1/2" NPT
ViewSonic Level display
ViewSonic Level + Leak Detection Switch
ViewSonic Features
ViewSonic Key Functions
MODE
When the display is in 'NORMAL' mode press 'MODE' to move between the current and
the historical information screens.
Press 'UP' to move between screens when in 'NORMAL' mode to view Gal, In,
or % of current liquid level .Use it to increase a setting when in 'SETUP' mode.
ENTER
The 'ENTER' key is used only during the 'SETUP' mode. Press to save the setting
shown on the display and then move automatically to the next 'SETUP' number.
Press 'DOWN' to move between screens when in 'NORMAL' mode to view Liquid
Level in Gal, In or %. Use it to decrease a setting when in 'SETUP' mode.
SETUP
Press 'SETUP' for 3 seconds to enter 'SETUP'. When in
'SETUP', press 'SETUP' to exit from 'SETUP' mode.
When in 'NORMAL' mode, by press together and release, the screen will flash the
current tank configuration for 20 seconds.
+
02
www.iconprocon.com
ViewSonic
User Manual
1
2 3 4 5 6
7
9
10
12
13
10
11
2. Viewsonic Level – Features and Functions
87
PRESS and HOLD UP or Down Arrows to Increase Selection Speed
Note:

ViewSonic Display features
1
Indicates the Tank Type being selected
TANK TYPE
A, B,C refers to tank shapes (see section 5)
A,B,C
The value displayed is the Room Temperature where display is located
ROOM TEMPERATURE
The value displayed is temperature in degrees Farenheit°F
in
H
The value displayed is in INCHES
The value displayed is the Tank Height ( Tanks A, B, C)
The value displayed is the tank width-(tank types B & C Only)
W
LED
The red light above the 'ENTER' key flashes when there is an Alarm condition (see section 6)
The Viewsonic Display displays valuable information during
normal use and during its initial setup and configuration for use
with your tank. The display contains three sections (1, 2, & 3) as
indicated in the diagram.
DISPLAY - SYMBOLS & INDICATORS
Screen (1) displays Programming number, Tank Type -during normal operation
displays room temperature.
Provide Liquid Level information including a visual bar-graph tank.
Information about the remaining usable liquid in Gal/Inches or % Tank Volume
1.
2.
3.
Numeric display - Shows the Room Temperature in normal mode e.g 20.
03
www.iconprocon.com
ViewSonic
User Manual
TANK TYPE
ROOM TEMPERATURE
EMPTY
H
W
A
B C
°F
FULL
LEAK ALARM
LIQUID LEVEL
%
in
Gal
/
18888
!

2
FULL
Indicates the 'Full' level of tank/drum being measured
Indicates the LCD display bargraph current liquid level
ViewSonic Monitor Display:
Bargraph indicator of liquid level - each bar represents 10% of tank height
ViewSonice Transmitter Display:
Tanks 10 ft (3m ) in height or greater - each bar represents 10 % of
tank height
LIQUID LEVEL
EMPTY
Indicates the 'Empty' level of the tank/drum being measured
LEAK DETECTION
ALARM
TANK LOW BATTERY
The flashing of the LED light and LCD bars indicates a leak has been
detected.
The ViewSonic Transmitter battery needs to be changed. (See page 11)
Flashing - Indicates that the liquid IeveI in the tank is at 10% or below of
tank height. (Appears on both the Viewsonic Display and Transmitter)
Flashing - There is a problem with the RF signal from the ViewSonic Sensor
(Appears on both the Display and Sensor)
Note : Reset Button located on back of Viewsonic Display
The temperature is close to or below the limit of operation of the ViewSonic
Sensor - the accuracy and battery life of the sensor may be affected.
!
!
3Inches
Gallons
Time
%
The value displayed is the % of liquid remaining in the tank.
Numeric display - used to show numeric values
Displayed value in Inches
Displayed value in Gallons
The value displayed in 24 Hour Clock
USB data connection.
04
www.iconprocon.com
ViewSonic
User Manual

TECHNICAL SPECIFICATIONS:
Tank Size
Displays
Min.Height : 1.6 ft ( 0.5m)
Max. Height: 10 Ft (3m)
Max. Tank Volume: 5200 Gal (19999L)
Multi-function LCD display including :
• 10 bar-graph level indication on both ViewSonic Display and Sensor
• Display of various current and historical values (ViewSonic Display only)
• Red LED provides low level indication less than of liquid remaining
Audible Alarm Audible alarm sounds every 60min (hourly) when the tank level is low
Max communication
distance
Typically 200 Ft in normal ‘line of sight’ conditions
Wireless
Communications 433MHz FM transmission (EN300-220)
Power Supply - 3V LiMn cell, CR2450
Power Supply for
Display
120 VAC, 50-60 Hz, meets EN60950-1
Battery Life Sensor : > 5 years (estimated life)
Display Monitor – approx 3yr of data
retention if display is not plugged in
Dimensions Sensor: 5.5" X 2.7" X 1.6" Display: 4.72" X 3.5" X 2"
Max and Min
Operation
(Transmitter)
Operating temperature range: -20°C to +60°C
Operating Humidity : 0 - 95% non-condensing
Hole size for
Fitting
Transmitter : 1.25" diameter
05
www.iconprocon.com
ViewSonic
User Manual
3.PRODUCT INFORMATION

Main Display Screen– provides current status of the liquid level of the tank.,and allows for easy visual
display 'Gal' or ,‘%’,or‘Days to empty’,as well the current time
06
www.iconprocon.com
ViewSonic
User Manual
4.DISPLAY SCREENS
In order calculate the volume in your tank the ViewSonic Display needs to know the shape of the tank.
There are three (3) basic shapes as illustrated below.Identify the shape that is closest to the shape of the
tank being measured. Each ViewSonic Display is supplied with the default settings as shown. The
ViewSonic Display must then be configured to match the tank’s dimensions that is goingto be measured
Type
Type A
Type B
Type C
Tank
Width Tank
Height
N/A N/A N/A
Tank
Width Tank
Height
5. TANK SETUP
Tank Capacity (Gallons)
Tank Height (in) Tank Width (in)
Low
Limit Default High
Limit Low
Limit Default High
Limit Low
Limit Default High
Limit
ROOM TEMPERATURE
FULL
LIQUID LEVEL
EMPTY
Gal
2O
°F
ROOM TEMPERATURE
FULL
LIQUID LEVEL
EMPTY
%
2O
°F
ROOM TEMPERATURE
FULL
LIQUID LEVEL
EMPTY
in
Current Time
2O
°F
ROOM TEMPERATURE
FULL
LIQUID LEVEL
EMPTY
2O
°F
Press
and

When the level in your tank is with
in 4" of the sensors transducter,the
main display will indicate‘FULL’.
Full Indication
Low Level Indications
Leak Detection Alarm (Model with Leak Detection Boyancy Switch)
If tank level reaches a low level the‘re-fill’symbol will flash.When the tank level is below 10% of
the usable volume of liquid left in the tank, the CURRENT information screen alternates between
showing the' Gal' and will indicate‘Lo’.on the display
If the Liquid level drops below 5% of liquid remaining :
This will continues until the tank is refilled with liquid
‘Lo’is displayed constantly on the Main screen.
The monitor there will be an audible beeps 5 times,
repeating every hourly,
The RED LCD light will begin to flash
07
www.iconprocon.com
ViewSonic
User Manual
6.LEVEL ALARMS / INDICATIONS
If the leak detection switch senses liquid it
will cause the red LED light and local LCD
display (bar graph) on the ViewSonic to
flash
If the remote ViewSonic display is utilized
the LCD (bar graph) and red LED light will
flash. An audible alarm will also become
active.
Press Enter to Cancel Audible Alarm on
remote Display
Note : LCD Bar graph,and LED Light will
continue to flash until upset alarm
condition is addressed and rectified
LCD Flashing +
Red LED LIght
ROOM TEMPERATURE
FULL
LIQUID LEVEL
EMPTY
Gal
2O
°F
FULL
ROOM TEMPERATURE
FULL
LIQUID LEVEL
EMPTY
Gal
2O
°F
Lo
ROOM TEMPERATURE
FULL
LIQUID LEVEL
EMPTY
Gal
2O
°
F
Lo
ROOM TEMPERATURE
FULL
LIQUID LEVEL
EMPTY
Gal
2O
°
F
85

If the ViewSonic Display does not receive or cannot
understand the RF signal from the Viewsonic
Sensor , an error message will be displayed on the
Display. The error message appears as an
alternating screen showing ‘Err’ and ‘E:0?’ where ? is
a number. Error codes are listed on a label on the
rear of your ViewSonic Display.
08
www.iconprocon.com
ViewSonic
User Manual
8.TROUBLESHOOTING
There is no need to 'Pair' the Sensor with the Display when theViewSonic
Sensor battery is changed.
Disposal :
The crossed out garbage symbol on the packaging indicates that this product and its battery shall not be
treated as household waste.
Proper disposal will help prevent potentially negative consequences for the environmentand human
health.
If the battery in theViewSonicTransmitter needs to be changed the display will provide advance
warning by showing the‘TANK LOW BATTERY’situatedbelowthebargraphwillbegintoflash
Remove theViewSonicTransmitter from the tank
The battery can be accessed by removing the four (4 )
screws from the base of the unit.
Remove the old battery and replace it with a new battery,3V
CR2450 type
Please ensure the O-ring is not damaged -relocate in the
correct position.
Connect theViewSonic transmitter to the top of the tank.
7. TRANSMITTER BATTERY CHANGE
ROOM TEMPERATURE
FULL
LIQUID LEVEL
TANK LOW BATTERY
EMPTY
Gal
2O
°
F
65O
ROOM TEMPERATURE
2O
°F
Err
!
ROOM TEMPERATURE
2O
°F
EO3
!

09
www.iconprocon.com
ViewSonic
User Manual
Check the transmitter is vertical on the tank.
Check positioning of the transmitter (ensure the transmitter is not too close to
the tank sides or internal obstructions).
Ensure that the transmitter is not too tightly attached to the tank.
Ensure that the tank is not overfilled and that the bottom of the transmitter is
clean.
Received
reading is
inconsistent
EO1
Reading not
received after
6 hours
E02
Reading
received but
void
E03
Received
Reading
greater than
tank height
E04
Contact
Vendor
EO5
Contact
Vendor
EO6
Error Description To Rectify :
Check the transmitter is within range of the monitor.Try and relocate the
monitor to a position that is nearer a window,remember that the transmitter
communicates with the monitor by use of an FM signaland moving the
monitor plug from possible metalobstructions can improve the signal.
Check that there are no metal obstruction that may deflect the signal.
Ensure the monitor is not too close to,or obstructed by,other electrical
appliances.
Check positioning of the transmitter (ensure the transmitter is not too close to
the tank sides or internal obstructions).
Ensure that the transmitter is not too tightly attached to the tank.
Ensure that the tank is not overfilled i.e.thereisaminimumof 4 inches
free space between the transmitter and level.
Ensure the bottom of sensor is clean.
Check the tank height and ensure this information is correct on the monitor,
press the 6.andV keys together to view your tank configuration.If height is
incorrect,enter the setup mode by pressing SETUP for thre seconds,
press ENTER until you reach screen 5 and adjust the height using 6.andV keys.
Press ENTER to save.Press SETUP to exit Setup mode.Wait 3 hours for updated
readings.
Check the transmitter is vertical and the positioning of the transmitter (ensure
the transmitter is not too close to the tank sides or internal obstructions).
This is a hardware fault please contact your distributor
This is a hardware fault please contact your distributor

Triangle - Not Flasing = Low Battery.
Remove ViewSonic sensor from the tank
Access the battery by removing the 4 sst screws from the
underside of the ViewSonic sensor
Remove and replace with a new battery (3VCR2450)
(Note + side up)
Replace upper cover with screws (do not overtighten) Ensure
O-Ring is in place and not damaged.
Reinstall the Viewsonic Sensor
d. Low Battery Signal
1.
2.
3.
4.
5.
10
www.iconprocon.com
ViewSonic
User Manual
Ensure (+
Pos) Sign is
facing out
Visual Low Level Indication
Pairing my not have activated correctly or battery may need to be replaced.
Repeat Step 3 or replace battery. If problem continues contact technical
support
a. Blank Screen
TROUBLESHOOTING (con't)
Viewsonic Sensor may not be positioned 90 degrees vertically on tank to the
liquid. Ensure sensor is vertical. Clear any obstacles in field of vision of the
sensor.
b. Full Screen but tank not full
Indicates lost ultrasonic echo. Ensure transducer ( sensing ) face is wiped
clean. Sensor not Vertical- Ensure sensor is positioned 90 degress to liquid.
c. Middle Bar + Flashing Triangle
!
!
Full50% Full
Almost
Empty
Empty

Battery Operated Ultrasonic
Level Sensor + Display + Leak Detection Switch
Installation Guide-Programming
Selectthe tanktypethatmostcloselymatchesthevesselyouareusing fromtheabovechart
STEP 1 - DETERMINETHE SHAPE OFYOURTANK/DRUM/
Determine the dimensions of your tank either from the manufacturer or by physically
measuring the Tank /Drum /Sump/Tote
For Double WalledTanks Only the Internal Dimensions andType (Chart) are required
The tank height,will be measured from the top of the tank,i.e.where theViewSonic Level
sensor will be mounted,tothebottomofthetank
(Note: Ensure the ViewSonic sensor is installed on the top of the internal tank if using a
double walled tank.)
Your tank/Drum/Sump
Dimension Chart
Tank
Type Width
(W) ins.
Brimful
Capacity
(Gls.)
Nominal
Capacity
(Gls.)
(95% of Brimful)
Height
(H) ins.
Type A - Rectangular/
cylindrical vertical
N/A
Type B - (H >=W) Oval/
cylindrical horizontal
Type C - (W > H) Lo profile
ViewSonic
11
www.iconprocon.com
ViewSonic
User Manual

Time
Minutes
TankType
Tank Capacity
Tank Height
OFT- Range Distance from
Sensor Face to Max Fill Height
OLH- Span- Height of Sludge or
Sediment in bottom of tank
Hours
Minutes
Type A - B - C
Gallons
Inches (max 88")
Inches (max 15")
AL On _Off
TankType A-Height Only ForTank
Type B & C Tank 'W" Width Required
ENTER
FAST
ENTER
FAST
ENTER
FAST
ENTER
FAST
ENTER
FAST
ENTER
FAST
ENTER
FAST
ENTER
FAST
STEP 2 – Programming DISPLAY
When first turning on the ViewSonic Dispay it will display the SETUP mode -In the top left
corner. Setup1. During the Programing Phase you will be guided through the Setup via
flashing screens.The 'Programming' is very intuitive and it is very easy to configure the display
to your specific application.
Note: that if you enter incorrect information simply continue to press ENTER until you are back
to the correct step where you can enter the correct value and press ENTER to store.
12
www.iconprocon.com
ViewSonic
User Manual

N.B.If you unable to measure your tank /sump / drum please confirm that you have selected the correct type...A-B or C
SETUP 1 – Setting the time (hrs)
Adjust the hour displayed using
/ .Press ENTER to save.
SETUP 2 – Setting the time (mins)
Adjust minutes displayed using
/ .
Press ENTER to save.
SETUP 4 – Programming the
tank/drum/sump capacity (ltr./
Gal.) Enter the number in litres/
gallons then Press ENTER to save
SETUP 5 – Programming tank/
drum/sump height (ins.)
Press ENTER to save.Note that
ifTankType‘A’was selected,
SETUP 6 will be skipped.
SETUP 6 (Type B & C tanks only)
Programming the in (inches)
Press ENTER to save.
SETUP 3 – Programming the tank
type Select tank type A,B,or C,
using / .to match your tank
then Press ENTER to save.
SETUP
SETUP
TANK TYPE
B
H
in
SETUP
TANK TYPE
A
SETUP
TANK TYPE
B
W
in
SETUP
SETUP
Gal
13
www.iconprocon.com
ViewSonic
User Manual
Setup 7
Setup 8
Programming Offset -OFT you are able to program the distance freom the Sensor face to the maximum
level of the liquid.This is measured in 'inches' and can be set from 0-19" Span
Programming Range -OFH
The Viewsonic Display can be programmed to account for sediment or sludge build-up located at the
bottom of the tank.Input value
SETUP
8
2
SETUP
8
OLH
SETUP
in
2
SETUP
OFt
OFT Distance from
Sensor Face to max
fill Height
OFT
max fill height
Off Set to account
for Buildup sludge or
sediment inside tank.
OFH
Sludge or Sediment Build-up

STEP 3 - PairingTHE SensorTOTHE Display
Alarm on : When a leak is sensed the ViewSonic Display will sound an audible beep and the
LCD Display will flash on the sensor as well as on the display.The LED red light on the sensor
will also light up and flash.The Audible sound can be turned off by pressing Enter
Alarm off :Turn alarm notification off .
Select AL ON/OFF using / .When the display shows your preferred setting press ENTER to save.
SETUP is now complete.Press SETUP to exit and progress to STEP 3.
On exiting Programming mode the monitor temporarily displays‘CALC’.
The Display must be in Pairing Mode (Lrn) mode which can
be entered in one of two ways:
A) Pressing SETUP after completing STEP 2 above
B) Disconnecting and reconnecting the power.The Pairing
mode (Lrn) the display shows ‘Lrn’ in the main screen area
(image 1).Pairing mode will last for approx 2 minutes during
which time you must‘match/pair’the sensor to the display.
The sensor LCD display should be facing in the same direction as the
LCD on the display as shown in image #4 base of the display.
Step 1 Position Sensor with Display-Hold for approx 5-10 Second
Step 2 If after 10 seconds syncing does not occur ( see Image 4)
Remove Sensor from Display for approx 5 seconds.-(Depending
on conditions this step may need to be repeated )
Step 3 Reposition Sensor with the Display (Image 3) Hold in place.
Once the units are connected the LCD bars on both the display and the
sensor with climb in sync while bars climb in sync, and audible beep is
emitted-This will indicate that the pairing is complete
Note: If at any stage during the Programming stage you exit SETUP mode , simply press and
hold the SETUP button for at least 3 seconds to begin again.
Setup 9 – Programming the-Leak DetectionVisual +Audible Alarm
Image 1 : ‘Lrn’mode Image 2 : Alignment Pin
Image 3 : Correct positioning Image 4 :Alignment
Image 4 :Syncing
9
On
SETUP
9
OFF
SETUP
9
On
SETUP
Press and
ROOM TEMPERATURE
2O
°F
Lrn
LrnLrnLrn
Continue to hold the transmitter and monitor together
14
www.iconprocon.com
ViewSonic
User Manual

STEP 4 - INSTALLING theViewSonic Senor
After the pairing’ is complete the sensor will send level data continuously to the display for approximately
ten (10 minutes). Every time the display receives data from the sensor a audible clicking noise will sound
and the red LED light will flash on the ViewSonic Sensor
The pairing procedure can be confirmed by slowly lowering and raising the ViewSonic level sensor over a
flat surface and observing that the display reflects the changes. The ‘Quick-Click’ mode will stop after 10
minutes. The Viewsonic Sensor is now ready to mounted onto the tank/drum/ sump .
Note: Keep the Sensor Perpendicular to the surface being measured
Note: if after 10 minutes the sensor is not mounted , the display may show the error symbol or display
an incorrect reading.Itmaytake1-2 hours before the correct level data is shown on the display screen.
Tanks with pre-drilled hole
A 2" or 1 1/2" MNPT Bulkhead fitting is provide for threading
directly onto the tank.
Ensure the transmitter is vertical to the liquid on top of the tank.
Ensure the LCD Bar Graph is displaying current liquid level
15
www.iconprocon.com
ViewSonic
User Manual

Battery Operated-
ViewSonic > 5 +Years
Battery Life
Wireless
Remote Display Up to 200 ft Away
Leak Detection
Should you have any questions,please contact
us : www.iconprocon.com
1-905 -469 9283
sales@iconprocon.com
The contents and images in this guide are subject to copyright and may not be
reproduced without the permission of Icon Process Controls Ltd
Contact Details
16
www.iconprocon.com
ViewSonic
User Manual
InstallationTips
Do not insert a down tube or
stillwell or any other object.
Aviod obstacles such as
ladders or mixers inside
the tank/sump
or drum
The transmitter must
be mounted vertical
YourViewSonic display and Level Sensor is now complete.
Ensure Sensor is Perpendicular
to Liquid Level

Notes & Calculations