Viking Range 15" Technical manual

USE/INSTALLATION
INSTRUCTIONS
1155””WW..UUNNDDEERRCCOOUUNNTTEERR//FFRREEEESSTTAANNDDIINNGGWWIINNEECCEELLLLAARR
RReettaaiinnffoorrFFuuttuurreeRReeffeerreennccee
VIKING RANGE CORPORATION
111 FRONT STREET
GREENWOOD, MISSISSIPPI 38930 USA
(662) 455-1200
IMPORTANT - PLEASE READ AND FOLLOW
••Before beginning, please read these instructions completely and carefully.
• Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty.
• Please observe all local and national codes and ordinances.
• Please ensure that this product is properly grounded.
• The installer should leave these instructions with the consumer who should retain for local inspector’s use and for
future reference.
WARNING::
TToorreedduucceetthheerriisskkooffffiirree,,eelleeccttrriiccaallsshhoocckk,,oorriinnjjuurryywwhheennuussiinnggyyoouurrwwiinneecceellllaarr,,ffoolllloowwbbaassiiccpprreeccaauuttiioonnssiinncclluuddiinnggtthhee
ffoolllloowwiinngg::
•FOR YOUR SAFETY•
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR
ANY OTHER APPLIANCE. THE FUMES CAN CREATE A FIRE HAZARD OR EXPLOSION.
IIttiissyyoouurrrreessppoonnssiibbiilliittyyttoobbeessuurreeyyoouurrwwiinneecceellllaarriiss::
•located so the front is not blocked to restrict incoming or discharge air flow.
•properly leveled.
•located in a well ventilated area.
•connected to the proper kind of outlet, with the correct electric supply and grounding. A 115 volt, 60 Hz, 15 amp
fused electrical supply is required. NNOOTTEE::Time delay fuse or circuit breaker is recommended.
•not used by anyone unable to operate it properly.
•used only for its intended purpose.
•properly maintained.
•SAVE THESE INSTRUCTIONS•
SSuuffffooccaattiioonnHHaazzaarrdd
RReemmoovveeddoooorrssffrroommyyoouurroolldd
rreeffrriiggeerraattiioonnuunniitt..
FFaaiilluurreettooddoossooccaannrreessuullttiinn
cchhi
illddeennttrraappmmeennttwwhhiicchhccaann
ccaauusseeddeeaatthhoorrbbrraaiinnddaammaaggee
IIMMPPOORRTTAANNTT::Child entrapment and suffocation are not problems of the
past. Junked or abandoned refrigeration products are still dangerous,
even if they will sit for “just a few days.” If you are getting rid of your
refrigeration product, please follow the instructions below to help
prevent accidents.
BBEEFFOORREEYYOOUUTTHHRROOWWAAWWAAYYYYOOUURROOLLDDRREEFFRRIIGGEERRAATTIIOONNUUNNIITT::
•Take off the doors.
•Leave the shelves in place so that children may not easily climb inside.
DANGER
PROPER DISPOSAL OF YOUR OLD REFRIGERATION UNIT
41009329
Rev. B

2
GENERAL INFORMATION
UUnnppaacckk
1. Remove banding from bottom of carton. Lift carton up and off of the wine cellar
2. Remove all tape and packaging material from the outside and inside of the cabinet.
3. Keep all carton packaging until your wine cellar has been thoroughly inspected and found to be in good condition.
AARREEAARREEQQUUIIRREEMMEENNTTSS
1. Place unit so the front side will be completely unobstructed to provide proper air flow. The unit may be closed in
on the top and three sides, but the front MMUUSSTTBBEEunobstructed for air circulation and proper operation.
Installation should be such that the cabinet can be moved for servicing if necessary.
2. Unit should be in a well ventilated area with temperature above 550F (130C) and below 1100F (430C). Best results
are obtained at temperatures between 650F (180C) and 800F (270C) for built-in models and between 650F (180C) and
900F (320C) for freestanding models.
3. Provisions for electricity should be determined before placing unit in proper place.
A
B
UNDERCOUNTER CABINET CUTOUT
AA15” (38.1 cm)*
BBMin. 34 1/2” (87.6 cm)
Max. 35 1/8” (89.2 cm)
CC24” (61.0 cm)
C
*15” (38.1 cm) width for cabinet only. If door
is recessed between cabinets, cabinet cutout
must be 15-1/4” (38.7 cm)

3
SPECIFICATIONS/DIMENSIONS -
Professional Models
BBaassiiccEElleeccttrriiccDDaattaa
•115 VAC/60 Hz
•Maximum amps - 3.0
•Approximate Shipping Weight - 110 lbs. (49.5 kg)
Front View
Side View
30 3/4”
(78.1 cm)
Min. 34 1/4”
(87.0 cm)
to
Max. 35”
(88.9 cm)
(with leveling
legs fully
extended.)
14 3/4” (37.5 cm)
21 3/16” (53.8 cm)
23 5/8” (60.0 cm)
26 1/8” (66.4 cm)
37 3/16” (94.5 cm)

4
SPECIFICATIONS/DIMENSIONS -
Designer Models
BBaassiiccEElleeccttrriiccDDaattaa
•115 VAC/60 Hz
•Maximum amps - 3.0
•Approximate shipping weight - 110 lbs (49.5 kg)
Front View
Side View
DUWC Side View
DFUW
30 3/4”
(78.1 cm)
Mín.
34 1/4”
(87.0 cm)
Max.
35”
(88.9 cm)
(with leveling
legs fully
extended.)
14 3/4” (37.5 cm)
21 3/16” (53.8 cm)
23 5/8” (60.0 cm)
24 5/8” ( 62.5 cm)
21 3/16” (53.8 cm)
23 7/16” (59.5 cm)
37 3/16” (94.5 cm)
37 3/16” (94.5 cm)
(to front of locally supplied
custom panel

5
CUSTOM WOOD FRAME INSTALLATION INSTRUCTIONS
((DDFFUUWWMMooddeell))
Note: Weight of wood panel must not exceed 20 lbs.
WWooooddSSccrreewwss
1. A #8 pan head wood screw should be used to properly secure the wood frame. A total of 8 screws will be needed
for a 3 1/2” (8.9 cm) kickplate or 7 screws for a 4” (10.2 cm) kickplate.
2. Only use pan head screws.
3. DO NOT select a screw that is longer than the wood thickness at
the screw locations.
4. Use recommended pilot holes for the frame material. (See chart)
WWoorrkkiinnggMMaatteerriiaallWWooooddSSccrreewwSSiizzee##88
Hardwood 3/32 (0.24 cm)
Softwood 5/64 (0.20 cm)
AAsssseemmbblliinnggDDoooorrHHiinnggeeBBrraacckkeettss
(Disregard if hinge brackets are already attached)
1. Attach the top and bottom door hinge brackets to the door with the #10-32 machine screws and a 1/8” allen head
driver as shown in Figure 1 below.
2. Press in the shoulder bushings to the top and bottom door hinge brackets. Make certain that the shoulder is to the
outside of the door as shown in Figure 1 below.
3. Test fit the door to the unit to make certain door will hang correctly. The door is hung correctly when the top of the
door is parallel to the top of the unit. (See Figure 2) Adjustments can be made by loosening the door hinge
machine screws and moving the door hinge brackets on the door.
4. Tighten all four (4) machine screws after adjustments have been made.
5. Remove the door from the unit by removing the units top hinge set screw and angling the door off of the bottom
hinge pin.
Figure 1
Figure 2
Shoulder Bushing
Door Hinge Bracket
#10-32 Machine
Screw
Door Hinge
Screw Holes
Door Front
Surface
This surface parallel to the unit.
(Right hinge door shown
TTyyppiiccaallTTooppaannddBBoottttoomm
DDoooorrHHiinnggeeBBrraacckkeett
AAsssseemmbbllyy

6
Selecting and Preparing the Wood Frame - DFUW Models
1/4” X 3/8” Deep hinge screw clearance hole. Locate and drill using
door hinge hole after the door has been aligned to the unit and when
the wood is positioned on door
1/4” X 3/8” Deep hinge screw clearance hole. Locate and drill using
door hinge hole after the door has been aligned to the unit and
when the wood is positioned on door
Mounting surface
(Non-face) side
Mounting surface
(non-face) side
Mounting surface
(non-face) side
Min. 5/8” (1.7 cm)
Max. 3/4” (1.9 cm) 14 15/16”
(36.4 cm)
7 5/32” (18.2 cm)
23/32”
(1.8 cm) TYP
1 23/32” (4.4) cm min.
width to cover door
extrusion
23/32”
(1.8 cm)
TYP
BACK VIEW OF
OVERLAY PANEL
30 5/16”
(77.0 cm)
Pre-drilled pilot holes -
8 places
7 13/16”
(19.8 cm)
TYP
15 5/32”
(38.5 cm)
TYP
22 1.2”
(57.2 cm)
TYP
13/16” (2.1 cm)
counterbore 7/16”
(1.1 cm) deep
15/32” (1.2 cm)
Dia. hole
15./2” (1.2 cm)
3 7/32”
(8.1 cm)
FFOORRAA33--11//22””TTOOEEKKIICCKK
((CCOOVVEERRSSTTHHEEEENNTTIIRREEDDOOOORREEXXTTRRUUSSIIOONN))
((LLEEFFTTHHIINNGGEE))

7
OOPPTTIIOONNAALLFFOORR44””TTOOEEKKIICCKK
TTOOMMAATTCCHHEEXXIISSTTIINNGGCCAABBIINNEETTRRYYTTOOEEKKIICCKKHHEEIIGGHHTT
((LLEEFFTTHHIINNGGEE))
1/4” X 3/8” Deep hinge screw clearance hole. Locate and drill using
door hinge hole after the door has been aligned to the unit and when
the wood is positioned on door
1/4” X 3/8” Deep hinge screw clearance hole. Locate and drill using
door hinge hole after the door has been aligned to the unit and
when the wood is positioned on door
Mounting surface
(Non-face) side
Mounting surface
(non-face) side
Mounting surface
(non-face) side
Min. 5/8” (1.7 cm)
Max. 3/4” (1.9 cm) 14 15/16”
(36.4 cm)
7 5/32” (18.2 cm)
23/32”
(1.8 cm) TYP
1 23/32” (4.4) cm min.
width to cover door
extrusion
23/32”
(1.8 cm)
TYP
BACK VIEW OF
OVERLAY PANEL
29 13/16”
(75.7 cm)
Pre-drilled pilot holes -
7 places
7 13/16”
(19.8 cm)
TYP
15 5/32”
(38.5 cm)
TYP
22 1.2”
(57.2 cm)
TYP
13/16” (2.1 cm)
counterbore 7/16”
(1.1 cm) deep
15/32” (1.2 cm)
Dia. hole
15/32” (1.2 cm)
3 7/32”
(8.1 cm)

8
1/4” X 3/8” Deep hinge screw clearance hole. Locate and drill using door hinge hole
after the door has been aligned to the unit and when the wood is positioned on door
Mounting surface
(Non-face) side
Mounting surface
(non-face) side
Min. 5/8” (1.7 cm)
Max. 3/4” (1.9 cm) 14 15/16”
(36.4 cm)
7 5/32” (18.2 cm)
1 23/32” (4.4) cm min. width to cover
door extrusion
23/32”
(1.8 cm)
TYP
30 5/16”
(77.0 cm)
Pre-drilled pilot holes -
8 places
15/32”
(1.2 cm)
3 7/32”
(8.1 cm)
15/32”
(1.2 cm)
Dia. hole
FFOORR33--11//22””TTOOEEKKIICCKK
((CCOOVVEERRSSTTHHEEEENNTTIIRREEDDOOOORREEXXTTRRUUSSIIOONN))
((RRIIGGHHTTHHIINNGGEE))
Mounting surface
(non-face) side
1/4” X 3/8” Deep hinge screw clearance hole. Locate and drill using
door hinge hole after the door has been aligned to the unit and when
the wood is positioned on door
23/32”
(1.8 cm) TYP
13/16” (2.1 cm) counterbore 7/16”
(1.1 cm) deep
BACK VIEW OF
OVERLAY PANEL
7 13/16”
(19.8 cm)
TYP
15 5/32”
(38.5 cm)
TYP
22 1.2”
(57.2 cm)
TYP

9
AAttttaacchhiinnggtthheeHHaannddllee
Attach the handle of your choice by drilling mounting holes through panel. Countersink or counterbore holes from back
side of panel for handle screw heads to be flush.
Mounting surface
(non-face) side
1/4” X 3/8” Deep hinge screw clearance hole. Locate and drill using
door hinge hole after the door has been aligned to the unit and when
the wood is positioned on door
OOPPTTIIOONNAALL44””TTOOEEKKIICCKK
TTOOMMAATTCCHHEEXXIISSTTIINNGGCCAABBIINNEETTRRYYTTOOEEKKIICCKKHHEEIIGGHHTT
((RRIIGGHHTTHHIINNGGEE))
1/4” X 3/8” Deep hinge screw clearance hole. Locate and drill using door hinge hole
after the door has been aligned to the unit and when the wood is positioned on door
Mounting surface
(Non-face) side
Mounting surface
(non-face) side
Min. 5/8” (1.7 cm)
Max. 3/4” (1.9 cm) 14 15/16”
(36.4 cm)
7 5/32” (18.2 cm)
1 23/32” (4.4) cm min. width to cover
door extrusion
23/32”
(1.8 cm)
TYP
29 13/16”
(75.7 cm)
Pre-drilled pilot holes -
7 places
15/32”
(1.2 cm)
3 7/32”
(8.1 cm)
15/32”
(1.2 cm)
Dia. hole
23/32”
(1.8 cm) TYP
13/16” (2.1 cm) counterbore 7/16”
(1.1 cm) deep
BACK VIEW OF
OVERLAY PANEL
7 13/16”
(19.8 cm)
TYP
15 5/32”
(38.5 cm)
TYP
22 1.2”
(57.2 cm)
TYP

10
Attaching the Wood Frame to the Door - DFUW Models
1. If the door is attached to the unit, remove by unscrewing the top allen head set screw at the top hinge. Remove
the door by angling the door off of the bottom hinge pin.
2. Install the supplied lock body into the wood panel. Secure the lock body by using the supplied 15mm lock
retaining nut. Screw the lock retaining nut on the lock body’s threaded section. Make sure the lock’s key slot is
vertical, then tighten the nut with a deep well socket.
3. Peel back the door gasket to expose the screw holes and lock location hole.
4. Set the wood frame flush to the front of the door in the desired location. Clamp the wood frame to the door if
necessary. Check to make sure the back of the lock in the wood frame lines up with the hole in the door.
5. Insert the wood screws through the back of the door into the pilot holes in the wood frame and tighten.
6. Assemble the door lock’s phillips head screw, the lock extension, and lock cam. Mount them to the back of the
lock body. The cam should be oriented vertically. Tighten the phillips head screw to secure the lock assembly.
7. Reinstall the door gasket by pressing into the door channel. Make certain the corners are inserted fully. Insert the
key into the lock and make sure the lock operates properly
8. Install the door to the unit. Use the supplied plastic washer as shown in the figure below.
9. Realigning the door may be necessary. Any final door adjustments can be made using a 1/8” allen head driver to
adjust the door’s hinges. (See figure below)
10. Attach the door light striker plate as shown using the 5/16” hex or phillips head screws provided. Make certain the
light is able to turn on and off when the door is opened and closed.
11. Attach the door to the unit by reversing step number 1 above.
12. Insert the key into the lock and verify that the lock cam works properly with the catch bracket on the cabinet front.
CAUTION
Door can become
disengaged if washers
are not installed.
CAUTION
Door can become
disengaged if
washers are not
installed.
Cabinet
Hinge
Wood
Frame
Door Hinge Door Hinge
Shoulder bushing
3/4” OD x 7/16”
ID Washer
3/4” OD x 1/4” ID
Washer
(3) Nylon hardware
components at
bottom hinge
CAUTION
Door may not swing properly
if all nylon components are
not installed as shown
Bottom Hinge Cover
Wood Frame
HHiinnggeeHHaarrddwwaarreeIInnssttaallllaattiioonn
DDeettaaiillss
Magnetic door gasket
Rear of Door
Door light striker plate
Bottom of
door
Door hinge adjustment
screws
Attached wood
frame
5/8”x 7/32” ID washer
Shoulder
bushing
3/8” clearance holes
for frame wood screws
- 8 holes
(2) Nylon
hardware
components at
top hinge
Top Hinge Cover
1/8” allen head screws for hinge
adjustment

11
WWAARRNNIINNGG
Do not lay unit on top, side, back, or front. If unit is
accidentally laid in any position other than right side
up, then the unit must remain in the right side up
position for at least 24 hours before plugging the unit
in.
1. Tip unit backwards so there is (1) foot of clearance
on front of the unit. Have someone to assist you in
tilting the unit, to prevent it from falling on you
while installing the leg levelers.
2. Screw front two leg levelers into the screw
impressions. Leg levelers should be screwed in until
snug.
3. Repeat steps 1 & 2, with the exception of tipping
the unit forwards now, to screw in the back two leg
levelers.
4. Your leg levelers are now installed.
5. The unit should be level from front to back and side
to side. If floor conditions do not allow the unit to
sit level, adjust leg leveler(s) by turning the required
leg leveler(s) counter-clockwise to increase their
height and clockwise to reduce their height.
Screw
Impressions
LLoocckkIInnssttaallllaattiioonnDDeettaaiillss
leg leveler installation
READ BEFORE INSTALLING LEG LEVELERS
LLoocckkBBooddyy
LLoocckkCCaamm
PPhhiilllliippssSSccrreeww
LLoocckkEExxtteennssiioonn
LLoocckkRReettaaiinneerrNNuutt
KKEEYY
DDoooorrGGaasskkeett
GGllaassssDDoooorr
WWooooddPPaanneell

12
EElleeccttrriiccaallRReeqquuiirreemmeennttss
A 115 volt, 60 Hz, AC only 15 amp fused electrical supply is required. (A time delay fuse or
circuit breaker is recommended.) It is recommended that a separate circuit, serving only this
appliance, be provided.
••EELLEECCTTRRIICCAALLGGRROOUUNNDDIISSRREEQQUUIIRREEDDOONNTTHHIISSAAPPPPLLIIAANNCCEE..
••DDOONNOOTTUUNNDDEERRAANNYYCCIIRRC
CUUMMSSTTAANNCCEESSRREEMMOOVVEETTHHEEPPOOWWEERRSSUUPPPPLLYYCCOORRDDGGRROOUUNNDD
PPLLUUGG..
••DDOONNOOTTUUSSEEAANNEEXXTTEENNSSIIOONNCCOORRDD
RReeccoommmmeennddeeddGGrroouunnd
diinnggMMeetthhooddss
For your personal safety, this wine cellar must be grounded. This appliance is equipped with a 7’ (2.1m) power supply cord
having a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong
grounding type wall receptacle grounded in accordance with the National Electrical Code and local codes and ordinances. If
the circuit does not have a grounding type receptacle, it is the responsibility and obligation of the customer to exchange the
existing receptacle in accordance with the National Electrical Code and applicable local codes and ordinances. The third
ground plug SHOULD NOT, under any circumstances, be cut or removed. All UL listed refrigerated products are equipped
with this type of plug.
Power Supply
with 3-prong
grounding plug
Grounding type
wall receptacle
FINAL PREPARATION
1. Some stainless steel parts may have a plastic protective wrap which must be peeled off. The interior of the wine cellar
should be washed thoroughly with hot, soapy water, rinsed and wiped dry to remove film residue and any installation dust
or debris before being used. Solutions stronger than soap and water are rarely needed.
2. All stainless steel parts should be wiped with hot soapy water. If buildup occurs, do not use steel wool, abrasive cloths,
cleaners, or powders. If it is necessary to scrape stainless steel to remove encrusted materials, soak with hot, wet cloths to
loosen the material, then use a wood or nylon scraper. Do not use a metal knife, spatula, or any other metal tool to scrape
stainless steel; scratches are almost impossible to remove.
WIRING DIAGRAM
UNDERCOUNTER/FREESTANDING 15” W. WINE CELLAR
WWAARRNNIINNGG::EELLEECCTTRRIICCAALL
GGRROOUUNNDDIINNGG
IINNSSTTRRUUCCTTIIOONNSS
This appliance is equipped with a
three prong grounding plug for
your protection against shock
hazard and should be plugged
directly into a properly grounded
three prong receptacle. Do not
cut or remove the grounding
prong from this plug.
ELECTRICAL CONNECTION
EElleeccttrriiccaallSShhoocckkHHaazzaarrdd
FFaaiilluurreettooffoolllloowwtthheesseeiinnssttrruuccttiioonnssccoouullddrreessuullttiinnffiirreeoorreelleeccttrriiccaallsshhooc
ckk..
WARNING

13
OPERATING INSTRUCTIONS
SSeettttiinnggtthheeCCoonnttrroollss
The total available temperature range of the unit is from 40 - 430F (4.4 -- 6.10C) to 64 - 660F (17.8 - 18.90C).
The middle range on the control is approximately 550F (12.80C). The higher the number selected, the
cooler the temperature within the unit. As with any refrigeration product, there is a slight temperature
variance at different locations within the cabinet. For example, the coolest area will be in the rear of the
lowest shelf. The area on the top shelf will be 3 - 70F warmer. This is the warmest location in the cabinet.
The area in the front will be 1 - 50F warmer than the area in the rear of the shelves.
To start your wine cellar, use a screwdriver to turn the control clockwise to the middle thermostat setting. Once the wine cellar
is loaded allow at least 48 hours for the unit to stabilize before making any adjustments to the initial setting.
TTiippssaannddSSuuggggeessttiioonnss
•After making a temperature adjustment, allow 24 hours for your wine cellar to reach a new temperature setting.
•The motor will start and stop often. It must do this to maintain the temperature setting.
•Unplug the wine cellar before working on anything with the electrical system.
•Exercise caution when sweeping, vacuuming, or mopping near the front of the unit. Damage to the grill and/or the light
fixture switch can occur.
LIGHT ASSEMBLY REPLACEMENT
NOTE: Please contact your local Viking Range
Corporation parts distributor or dealer to order new light
assembly.
To replace the light, first disconnect the wine cellar’s
power cord. Next, remove both the green ground wire
screw located on the left of the light assembly and the
other screw located on the right of the light assembly with
a 5-16” hex head screwdriver. (See drawing). Unplug the
light unit and remove complete light assembly.
To install the new light assembly, screw in the green ground wire screw and the screw
located on the right with a 5/16” hex head screwdriver and plug the light unit in.
Plug
Hex head
screw
Light
assembly
Green
ground wire
Hex head
screw
INTERIOR LIGHT
The interior light allows you to view your wine cellar contents. When the switch is in the “OFF” position, the
light will come on only when the door is opened. In the “ON” position, the light remains on continuously.
WARNING Failure to disconnect the power cord when changing the
light assembly may result in electric shock.
LOADING RECOMMENDATIONS
Each of the six roll-out racks hold four bottles. The necks of the bottles alternate front
to back. To aid in loading/unloading, the racks extend up to 14 inches (35.6 cm) to
allow easier access to the rear bottles. Bottom racks may be removed for storing “jug’”
wines. Magnums and other large bottles may be stored by removing the rack directly
above the intended storage rack. To remove a rack, first unlock the rack by pushing the
lock backward. The lock is located on the bottom front of each rack. After reinserting
the rack, push the lock forward to lock the rack back into place.
Bottles on the top rack directly under the light will be exposed to slightly higher
temperature when the light is on. Store red wines on the upper racks where the
temperature is higher and white wines on the middle or lower racks where the
temperature is lower. REMEMBER TO TURN OFF THE LIGHT WHEN IT IS NO
LONGER NEEDED. Roll-out Racks

14
CLEANING AND MAINTENANCE
Any piece of equipment works better and lasts longer when maintained properly and kept clean.
CCoonnddeennsseerr
The condenser tubing inside the cabinet does not require frequent cleaning; however, satisfactory cooling depends on
adequate ventilation over the coils. Be sure that nothing obstructs the required air flow openings in front of the cabinet.
Spiders and insects can nest in and around the wine cellar causing damage to the unit. Frequently brush or vacuum lint
and dirt from the condenser coils for efficient performance by unscrewing the grill on the bottom front of cabinet.
CCaabbiinneett
The cabinet can be washed with mild soap and water and thoroughly rinsed with clear water. Never use abrasive scouring
powders.
IInntteerriioorr
Wash interior compartment with mild soap and water. Do not use abrasive powder, solvent, polish cleaner or undiluted
detergent.
SSttaaiinnlleessssSStteeeellPPaarrttss
All stainless steel parts should be wiped regularly with hot soapy water. Use a liquid cleaner designed for stainless steel
when soapy water will not do the job. DDoonnoottuusseesteel wool, abrasive cloths, cleansers, or powders. Do not permit citrus
or tomato juice to remain on stainless steel surfaces, as citric acid will permanently discolor stainless steel.
BBrraassssPPaarrttss
CCAAUUTTIIOONN::All brass parts have an epoxy coating. DDOON
NOOTTUUSSEEBBRRAASSSSOORRAABBRRAASSIIVVEECCLLEEAANNEERRSSOONNTTHHEEBBRRAASSSS
PPAARRTTSS..All brass parts should be wiped regularly with hot soapy water. When hot soapy water will not do the job, use
every day non-abrasive household cleaners.
GGllaassssDDoooorr
Use a glass cleaner or mild soap and water with soft cloth to clean the glass door. Do not use any abrasive powders.
DDoooorrGGaasskkeett
The vinyl gasket may be cleaned with mild soap and water, a baking soda and water solution, or a mild scouring powder.
On full overlay models, use caution when cleaning near the logo area.
PPaaiinntteeddSSuurrffaacceess
Wash with warm soapy water. DDOONNOOTTUUSSEEsteel wool, abrasive cleansers, ammonia, acids or commercial oven cleaners
which may damage the finish.
LOADING RECOMMENDATIONS (con’t)
Store wines intended for everyday use on the front half of the racks where labels are completely visible and place wines
for aging or long term storage in the rear half of the rack. Pull wine racks out gently to minimize the unsettling of your
wine collection. Avoid pulling out more than one rack at any time to maintain stability.
Since the bottles are not
stacked on top of each
other, the single bottle rack
allows easy view and access
to your inventory without
disturbing other bottles
Front Bottles
(Necks Facing Rear)
Rear Bottles
(Necks Facing Front)

15
Record the following information indicated below. You will need it if service is ever required. The serial number and
model number for your wine cellar is located on the front of the unit at the base of the door frame.
Model Number Serial Number
Date of Purchase Date Installed
Dealer’s Name
Address
IIffsseerrvviicceerreeqquuiirreessiinnssttaallllaattiioonnooffppaarrttss,,uusseeoonnllyyaauutthhoorriizzeeddppaarrttssttooeennssuurreepprrootteeccttiioonnuunnddeerrt
thheewwaarrrraannttyy..
TThhiissmmaannuuaallsshhoouullddrreemmaaiinnwwiitthhtthheewwiinneecceellllaarrffoorrffuuttuurreerreeffeerreennccee..
SERVICE INFORMATION
It is assumed that your wine cellar has been properly installed in accordance with all specifications and local codes and the
appliance has been properly grounded. If your wine cellar should fail to operate, review the troubleshooting chart before
calling for service.
If service is required:
1. Call your dealer or authorized service agency. The name of the authorized service agency can be obtained from the
dealer or distributor in your area.
2. Have the following information readily available:
•Model number
•Serial number
•Date of purchase
•Name of dealer from whom purchased
If you are unable to obtain the name of an authorized service agency, or if you continue to have service problems, contact
Viking Range Corporation at (888) 845-4641 or write to:
VVIIKKIINNGGPPRREEFFEERRRREEDDSSEERRVVIICCEE
111111FFrroonnttSSttrreeeett
GGrreeeennwwoooodd,,MMiissssiissssiippppii3388993300UUSSAA
TROUBLESHOOTING CHART
PPrroobblleemmPPoossssiibblleeCCaauussee//SSoolluuttiioonn
Odor in cabinet Interior needs cleaning.
Noisy operation/cabinet vibrates Cabinet not level; weak floor.
Cabinet light not working Bulb burned out; no power at outlet.
Appliance will not run Temperature control to “OFF”; line cord not plugged in; no power at
electrical outlet; house fuse blown.
Appliance runs too long Prolonged door openings; control set too cold; condenser needs
cleaning
Moisture collects inside Too many door openings; prolonged door openings; (hot, humid
weather increases condensation)
Moisture collects to outside surface (Hot, humid weather increases condensation); control improperly set.
Interior too hot/too cold Control improperly set; faulty thermometer; (relocate thermometer to
center of cabinet and recheck)
ENERGY SAVING TIPS
•Reduce door openings.
•Close the door as soon as you can.
•Keep the condenser coils on bottom of the wine cellar clean. (See “Cleaning and Maintenance”.)
•Adjust the temperature control to a warmer setting when practical.
•Install unit away from the stove or other heat sources.

UNDERCOUNTER/FREESTANDING WINE CELLAR WARRANTY
TTWWOOYYEEAARRFFUULLLLWWAARRRRAANNTTYY
Built-in/freestanding undercounter wine cellars and all of their components and accessories, except as detailed below*, are warranted to be free from defects in material or
workmanship under normal household use for a period of two (2) years from the date of original retail purchase. Viking Range Corporation, warrantor, agrees to repair or
replace, at its option, any part which fails or is found to be defective during the warranty period
*Painted and decorative items are warranted to be free from defective materials or workmanship for a period of ninety (90) days from the date of original retail purchase.
ANY DEFECTS MUST BE REPORTED TO THE SELLING DEALER WITHIN NINETY (90) DAYS FROM DATE OF ORIGINAL RETAIL PURCHASE.
SSIIXXYYEEAARRFFUULLLLWWAARRRRAANNTTYY
Any sealed refrigeration system component, as listed below, is warranted to be free from defective materials or workmanship in normal household use during the third
through the sixth year from the date of original retail purchase. Viking Range Corporation, warrantor, agrees to repair or replace, at its option, any part which fails or is found
to be defective during the warranty period.
SSeeaalleeddRReeffrriiggeerraattiioonnSSyysstteemmCCoommppoonneennttss::Compressor, Evaporator, Condenser, Connecting Tubing, Dryer/Strainer
TTWWEELLVVEEYYEEAARRLLIIMMIITTEEDDWWAARRRRAANNTTYY
Any sealed refrigeration system component, as listed above, which fails due to defective materials or workmanship in normal household use during the seventh through the
twelfth year from the date of original retail purchase will be repaired or replaced, free of charge for the part itself, with the owner paying all other costs, including labor.
NNIINNEETTYY((9900))DDAAYYRREESSIIDDEENNTTIIAALLPPLLUUSSWWAARRRRAANNTTYYThis warranty applies to applications where use of the product extends beyond normal residential use.
Examples are, but not limited to, bed and breakfasts, fire stations, private clubs, churches, etc. This warranty excludes all commercial locations such as restaurants,
food service locations and institutional food service locations.
This warranty extends to the original purchaser of the product warranted hereunder and to each transferee owner of the product during the term of the warranty.
This warranty shall apply to products purchased and located in the United States and Canada. Products must be purchased in the country where service is requested.
Warranty labor shall be performed by an authorized Viking Range Corporation service agency or representative. Warranty shall not apply to damage resulting from abuse,
accident, natural disaster, loss of electrical power to the product for any reason, alteration, improper installation, improper operation or repair or service to the product by
anyone other than an authorized Viking Range Corporation service agency or representative. Warranty shall not apply to damage resulting from indoor units being used in
outdoor situations. This warranty does not apply to commercial usage. Warrantor is not responsible for consequential or incidental damage whether arising out of breach of
warranty, breach of contract, or otherwise. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or
exclusion may not apply to you.
Owner shall be responsible for proper installation, providing normal care and maintenance, providing proof of purchase upon request, and making the appliance reasonably
accessible for service. If the product or one of its component parts contains a defect or malfunction during the warranty period, after a reasonable number of attempts by
the warrantor to remedy the defects or malfunctions, the owner is entitled to either a refund or replacement of the product or its component part or parts. Replacement of a
component part includes its free installation. Warrantor’s liability on any claim of any kind, with respect to the goods or services covered hereunder, shall in no case exceed
the price of the goods or service or part there of which gives rise to the claim.
WWAARRRRAANNTTYYSSEERRVVIICCEE::Under the terms of this warranty, service must be performed by a factory authorized Viking Range Corporation service agent or representative.
Service will be provided during normal business hours, and labor performed at overtime or premium rates shall not be covered by this warranty. To obtain warranty service,
contact the dealer from whom the product was purchased, an authorized Viking Range Corporation service agent, or Viking Range Corporation. Provide model and serial
number and date of original purchase. For the name of your nearest authorized Viking Range Corporation service agency, call the dealer from whom the product was
purchased or Viking Range Corporation. IIMMPPOORRTTAANNTT::Retain proof of original purchase to establish warranty period.
The return of the Owner Registration Card is not a condition of warranty coverage. You, however, should return the Owner Registration Card so that Viking Range
Corporation can contact you should any question of safety arise which could affect you.
Any implied warranties of merchantability and fitness applicable to the above described undercounter wine cellar are limited in duration to the period of coverage of the
applicable express written limited warranties set forth above. Some jurisdictions do not allow limitations on how long an implied warranty lasts, so the above limitation may
not apply to you. This warranty gives you specific rights, and you may also have other rights which may vary from jurisdiction to jurisdiction.
Viking Range Corporation
111 Front Street • Greenwood, Mississippi USA • 38930 (662) 455-1200
www.vikingrange.com
Specifications subject to change without notice
F20345B (PS0806VR)
This manual suits for next models
1
Table of contents
Other Viking Range Wine Cooler manuals