DCH 12”H. Classic Chimn y Wall Hoods w/Standard V ntilator
Dim nsions & Sp cifications ________________________________________________________________________ 5
Cl aranc Dim nsions _____________________________________________________________________________ 6
Int rior V ntilator Dim nsions_______________________________________________________________________ 7
DPPV Custom Pow r Packs w/Standard V ntilator
Dim nsions & Sp cifications ________________________________________________________________________ 8
Installing Hood Canopy ____________________________________________________________________________ 9
Cl aranc Dim nsions ____________________________________________________________________________ 10
Int rior V ntilator Dim nsions _____________________________________________________________________ 11
DCWH/DCWN/DCWL Classic Chimn y Wall Hoods—
L dg l ss & L dg 30”, 33”, 36”, 39”, 42”, 45”, 48”, & 51”
Dim nsions & Sp cifications _______________________________________________________________________ 12
Cl aranc Dim nsions_____________________________________________________________________________13
Int rior V ntilator Dim nsions _____________________________________________________________________ 14
Ext rior V ntilator Dim nsions ____________________________________________________________________ 15
DCIH Classic Chimn y Island Hoods 36”, 42”, & 54”
Dim nsions & Sp cifications _______________________________________________________________________ 16
Cl aranc Dim nsions_____________________________________________________________________________17
Int rior V ntilator Dim nsions ______________________________________________________________________18
Ext rior V ntilator Dim nsions ____________________________________________________________________ 19
DTWS Slim Traditional Wall Hoods 30”, 36”, 42”, & 48”
Dim nsions & Sp cifications _______________________________________________________________________ 20
Cl aranc Dim nsions ____________________________________________________________________________ 21
Int rior V ntilator Dim nsions ______________________________________________________________________ 22
Ext rior V ntilator Dim nsions _____________________________________________________________________23
DTWN Tall Traditional Wall Hoods—L dg l ss 30”, 36”, 42”, & 48”
Dim nsions & Sp cifications _______________________________________________________________________24
Cl aranc Dim nsions_____________________________________________________________________________25
Int rior V ntilator Dim nsions _____________________________________________________________________26
Ext rior V ntilator Dim nsions _____________________________________________________________________27
DBCV Wall Custom V ntilator Syst m
Dim nsions & Sp cifications _______________________________________________________________________28
Installing Hood Canopy ___________________________________________________________________________29
Cl aranc Dim nsions ____________________________________________________________________________ 30
DBCV V ntilator Dim nsions _______________________________________________________________________31
DICV Island Custom V ntilator Syst m
Dim nsions & Sp cifications_______________________________________________________________________ 33
Installing Hood Canopy ___________________________________________________________________________ 34
Cl aranc Dim nsions ____________________________________________________________________________ 35
DICV V ntilator Dim nsions ________________________________________________________________________36
Planning Information __________________________________________________________________________________ 38
Installation Proc dur
Installation (DCH 12”H. Classic Chimn y Wall Hoods w/Standard V ntilator) ____________________________ 39
Duct Cov r Option (DCH 12”H. Classic Chimn y Wall Hoods w/Standard V ntilator) _____________________ 41
Installation (DCH 12”H. Classic Chimn y Wall Hoods w/R circulating Kit) _______________________________ 42
Installation (DCWH/DCWN/DCWL Classic Chimn y &
DTWN Tall Traditional Wall Hoods) ________________________________________________________________ 44
Duct Cov r Option (DCWH/DCWN/DCWL Classic Chimn y Wall Hoods) _______________________________ 45
Duct Cov r Option (DTWN Tall Traditional Wall Hoods) _______________________________________________ 46
Installation (DTWS Slim Traditional) _________________________________________________________________ 46
Duct Cov r Option (DTWS Slim Traditional Wall Hoods) ______________________________________________ 48
Installation (DCIH Classic Chimn y Island Hoods) ____________________________________________________ 50
S rvic & R gistration_________________________________________________________________________________ 52
3
IMPORTANT–Please Read and Follow!
NOTE:
If installing hood with warming shelf panel,
install warming shelf panel first.
IMPORTANT PLEASE READ AND FOLLOW
• B for b ginning, pl as r ad th s instructions
compl t ly and car fully.
• Do not r mov p rman ntly affix d lab ls, warnings, or
plat s from th product. This may void th warranty.
• Pl as obs rv all local and national cod s and
ordinanc s. If no local cod s ar applicabl , wir in
accordanc with th National El ctrical Cod ,
ANSI/NFPA 70-lat st dition.
• Th install r should l av th s instructions with th
consum r who should r tain for local insp ctor’s us and
for futur r f r nc .
• Ch ck with a qualifi d and train d install r or local cod s
for mak up air r quir m nt, if any.
This hood is for r sid ntial installation only and is not
d sign d for installation ov r a comm rcial product. Mak
sur pow r is off at th main circuit br ak r or fus box
b for making conn ctions. To avoid risk of fir , l ctric
shock, or injury to p rsons, turn off th l ctricity to th
hood from th pow r supply b for s rvicing or cl aning.
Viking hoods ar quipp d with th variabl sp d
controls for blow rs. Th s units will not function with a
singl sp d v ntilator. All Viking v ntilator kits ar
d sign d sp cifically for us with Viking hoods. Us of any
non-Viking v ntilator kit will void th hood warranty.
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF A RANGETOP
GREASE FIRE
1. N v r l av surfac units unatt nd d at high
s tting. Boilov rs caus smoking and gr asy
spillov rs that may ignit . H at oils slowly on
low or m dium s ttings.
2. Always turn hood ON wh n cooking at high
h at or wh n cooking flaming foods. (i. . cr p s
suz tt , ch rri s jubil , p pp rcorn b f
flambé).
3. Cl an v ntilating fans fr qu ntly. Gr as should
not b allow d to accumulat on fan or filt r.
4. Us prop r pan siz . Always us cookwar
appropriat for th siz of th surfac l m nt.
TO REDUCE THE RISK OF FIRE, ELECTRICAL
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING
1. Installation work and l ctrical wiring must b
don by qualifi d p rson(s) in accordanc with
all applicabl cod s and standards, including
fir -rat d construction.
2. Suffici nt air is n d d for prop r combustion
and xhausting of gas s through th flut
(chimn y) of fu l burning quipm nt to pr v nt
back drafting. Follow th h ating quipm nt
manufactur r’s guid lin and saf ty standards
such as thos publish d by th National Fir
Prot ction Association (NFPA), and th
Am rican Soci ty for H ating, R frig ration and
Air Conditioning Engin rs (ASHRAE), and th
local cod authoriti s.
3. Wh n cutting or drilling into wall or c iling, do
not damag l ctrical wiring or oth r hidd n
utiliti s.
4. Duct d fans must always b v nt d to th
outdoors.
5. WARNING!: To r duc risk of fir , us only
m tal ductwork.
6. CAUTION!: To r duc risk of fir and to
prop rly xhaust air, b sur to duct air outsid .
Do not v nt xhaust air into spac s within walls
or c ilings, or into attics, crawl spac s, or
garag s.
7. CAUTION!: To R duc th Risk of Fir and
El ctric Shock, Install this rang hood only with
r mot blow r mod ls manufactur d by Viking,
mod l numb rs – DEV900/DEV1200,
VEV900/VEV1200, OR DEV1500, VEV1500 or
int gral blow rs manufactur d by Viking, mod l
numb rs – DIV300, DIV440, DIV600, DIV800,
DIV1200, VIV300, VIV600, or VIV1200. NOTE –
Pl as r f r insid for sp cific canopy/blow r
combinations.
WARNING
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING
• Us this unit only in th mann r int nd d by th
manufactur r. If you hav any qu stions, contact