VIRDI 3000 User manual

VIRDI 3000 .Installation Guide
Version eng-1.01

VIRDI 3000 Installation Guide 3
Table of Contents
< GLOSSARY>..........................................................................................................2
1. BEFORE START....................................................................................................4
1.1. Safety precautions ............................................................................................4
1.2. Terminal description .........................................................................................5
1.3. Button description ............................................................................................5
1.4. Screen (during operation) description ............................................................6
1.5. Voice information during operation.................................................................7
1.6. Buzzer sound during operation .......................................................................7
1.7. LED signal during operation ............................................................................7
1.8. Correct fingerprint registration and input methods.......................................8
2. INTRODUCTION..................................................................................................10
2.1. Features ...........................................................................................................10
2.2. Configuration...................................................................................................12
2.2.1. Network configuration.................................................................................. 12
2.2.2. Single configuration..................................................................................... 12
2.3. Specifications..................................................................................................13
3. INSTALLATION GUIDE.......................................................................................14
3.1. Product Composition Items............................................................................14
3.2. Installation Environment Conditions.............................................................16
3.2.1. Environment Conditions .............................................................................. 16
3.3. Main Board Composition................................................................................17
3.4. PIN Specifications of Each Product Part.......................................................18
3.5. Installation .......................................................................................................19
3.5.1. Installation Process (All) .............................................................................. 19
3.5.2. Installation Process Order (Detailed)........................................................... 19
4. FAQ......................................................................................................................32

VIRDI 3000 Installation Guide 4
1. Before start
1.1. Safety precautions
zWarning
Handling with wet hands or
allowing liquid to flow into it
is not advised.
-> It may cause an
electric shock or damage.
Do not place a fire source
near the unit.
-> It may cause a fire.
Do not disassemble, repair,
or modify the unit.
-> It may cause an electric
shock, fire or damage.
Keep out of reach of
children.
-> It may cause an
accident or damage.
-If the above warnings are ignored, it may result in death or serious injury.
-
zCautions
Keep away from direct
sunlight
-> It may cause
deformation or color
change.
Avoid high humidity or
dust ->The unit may be
damaged.
Avoid using water,
benzene, thinner, or
alcohol for cleaning
-> It may cause an electric
shock or fire.
Do not place a magnet
close to the unit.
-> The unit may break
down or malfunction.
Do not contaminate the
fingerprint input area.
-> Fingerprints may not be
well recognized.
Avoid using insecticides
or flammable sprays near
the unit.
-> It may result in
deformation or color
change.
Avoid impacts or using
sharp objects on the unit.
-> The unit may be
damaged and broken.
Avoid severe temperature
changes
-> The unit may be
broken.
- If the above cautions are ignored, it may result in property loss or human injury.
※Under no circumstances will Union Community be responsible for accidents or
damages caused by inappropriate use of the product caused by not referring to
the user manual.

VIRDI 3000 Installation Guide 5
1.2. Terminal description
1.3. Button description
Visitors use this to ring the interphone bell
Use after entering the settings when configuring the terminal
environment
Speaker :
Explanation of operation
state and communication
with interphone
Fingerprint input window :
Window for fingerprint input
LCD display window :
Display character message for
all the operations
Card input position
: Option
Mic :
Connect to interphone
Ke
yp
ad : Enter numbers for environment settin
g
or authentication ID in
p
u
t
LED lamp : Terminal operation state
¾PWR : ON when VIRDI 3000 is under normal operation
¾DOOR: Yellow ON when electronic door open/close unit is open after authentication
Red ON when the terminal case is open
start
leave
outside work
come back to company
Clear typo when entering settings
Move up to higher menu
use when escaping from menu setting
Enter ‘0’ or LCD menu scroll
Terminal menu setting
(enter into menu mode
when pressed over 2 sec.)

VIRDI 3000 Installation Guide 6
1.4. Screen (during operation) description
== 00:00
- Initial screen
== 00:00
- Waiting for a user’s ID to be input
== 00:00
- Fingerprint input
== 00:00
- Password input
== 00:00
- Authentication successful
== 00:00
- Authentication failed
== 00:00
- Entered a non-registered user ID
- Connection method is SN and 1:N identification is
accessed even though there is no user allowed for
1:N identification
== 00:00
- When the terminal is under meal control mode, a
user tries authentication during meal time.
== 00:00
- There is no response from the server during the
authentication process.
- Network to server is disconnected during the
authentication process.
ÆÅ 00:00
- There is no user registered on the terminal or no
connection to the server, so it is trying to connect.
== connected to network server
ÆÅ disconnected to network server
in/out display during in/out control ( F1, F2, F3, F4 )
start/leave display during start/leave control ( START, LEAVE, OUT, BACK, NORMAL )
menu display during meal control ( MENU-1, MENU-2, MENU-3, MENU-4 )
== START 00:00
Current time
Information message

VIRDI 3000 Installation Guide 7
== 00:00
- Waiting for card to be input
== 00:00
- A registered user tried authentication
when entry/exit is not allowed.
== 00:00
- Waiting for a reply from the server
for authentication
== 00:00
- Terminal is locked
- No meal time even though the unit is set to meal
control mode
== 00:00
- Terminal program upgrade
(Power switch should not be turned off when this
message is displayed.)
1.5. Voice information during operation
“Please enter your fingerprint” Enter fingerprint using the fingerprint input
window
“You are authorized” Authentication successful
“Please try again” Authentication failed
1.6. Buzzer sound during operation
“ppig”
When a button is pressed or a card is being read
When fingerprint input is completed, allowing the user to
remove his fingerprint
“ppibig” Authentication failed or wrong user input
“ppiriririck” Waiting for fingerprint input
“ppiririck” Authentication successful or settings for the current user are
completed
1.7. LED signal during operation
PWR ●Power On/Off
DOOR ●
[2 color] ●
Door Open/Close
Terminal Case Open/Close

VIRDI 3000 Installation Guide 8
1.8. Correct fingerprint registration and input methods
zCorrect fingerprint registration methods
Place your index finger on the window just as you do with a finger stamp.
Finger tip touching is not an appropriate registration or input method.
Make sure the center of your finger touches the window.
zUse your index finger.
The index finger guarantees an accurate and stable fingerprint input.
zCheck if your fingerprint is unclear or damaged.
It is tricky to recognize fingerprints on dry, wet, unclear, or injured fingers.
Use another finger in this case.

VIRDI 3000 Installation Guide 9
zCautions about fingerprint condition
Depending on the user’s fingerprint condition, some fingerprints may not be
used or may cause an inconvenience.
If the fingerprint is damaged or very unclear, then it cannot be recognized.
Please use a password instead in this case.
When a finger is dry, breathe on the finger for smooth operation.
For kids, it may be tricky or impossible to use the unit because their
fingerprints are too small or very unclear. It is recommended to register
their fingerprints every six months.
For the elderly, it may not be possible to register their fingerprints if there
are too many fine lines on the fingerprints.
If fingerprints are very unclear, it may be convenient if you register 2~3
fingerprints.
It is recommended that you register more than 2 fingerprints.

VIRDI 3000 Installation Guide 10
2. Introduction
2.1. Features
zAccess control system using LAN
-Communication between the unit and authentication server is done through
a UTP cable and TCP/IP protocol, so an existing LAN can be used as it is.
It guarantees network-based administration and monitoring as well as easy
expansion, high reliability, and higher speed.
zConvenient Auto Sensing function
-Simple authentication process without any key input; simple fingerprint
touching is sufficient.
zSimple authentication using fingerprints
-Due to Biometrics fingerprint recognition technology, it is not necessary to
carry a password, card, or key, etc., or to worry about robbery. This
improves the level of security.
zHigh capacity of terminal and server
-There is no limit on fingerprint registration for the server, and the unit itself
can store up to 8,000 fingerprints.
zVarious information messages
-It ensures easy fingerprint recognition because voice and LCD window
information are provided during the authentication process. In addition, the
backlight installed in the LCD window helps with easy key operation in the
dark.
zDoor phone
-Easy visitor identification and convenient response.
zVarious and flexible Access controls
-No risk of rent, forgery, or loss of keys or cards
-Perfect control by assigning different security clearances to each user or
group
-Provides flexibility by allowing limited time for entry/exit
-Low maintenance and development costs compared to other units
-No need to issue a visitor card to a visitor
zVarious applications including entry/exit, start/leave, meal counting, etc.
-Various operation modes depending on the terminal menu settings

VIRDI 3000 Installation Guide 11
zVarious registration and authentication methods
-There are a total of 11 registration and authentication methods (4 methods
if the card reader is not installed), so you are required to select one method
before registering users and an administrator.
FP Fingerprint registration
Fingerprint authentication
ID&PW Password registration
Password authentication
FP|PW Fingerprint and password registration
Fingerprint or password authentication
FP&PW Fingerprint and password registration
Password authentication after fingerprint authentication
RF Card registration
Card authentication
RF|FP Card and fingerprint registration
Card or fingerprint authentication
RF&FP Card and fingerprint registration
Fingerprint authentication after card authentication
RF|PW Card and password registration
Card or password authentication
RF&PW Card and password registration
Password authentication after card authentication
ID&FP|RF&FP Card and fingerprint registration
Fingerprint authentication after ID input or fingerprint
authentication after card authentication
ID&PW|RF&PW Card and password registration
Password authentication after ID input or password
authentication after card authentication

VIRDI 3000 Installation Guide 12
2.2. Configuration
2.2.1. Network configuration
Network Server
(authentication Server)
2.2.2. Single configuration
UTP
LET
UTP
WAN
TCP/IP
UTP
Switch Hub
4
3
562
643 2
2
13456 8
7
9
10 1112
2
643
12
2
6423
5123
4
678
9
10111
2
Tx
R
x
1
Tx
R
x
2
Tx
R
x
1
Tx
R
x
21
2
3
T
x
R
x
1
Tx
R
x
2
641 3
4
T
x
R
x
1
T
x
R
x
2
1
6410
34
T
x
R
x
1
TxRx
2
1
641
UTP
UTP
UTP
UTP
Door phone
Door Lock System
V
IRDI 3000

VIRDI 3000 Installation Guide 13
2.3. Specifications
Item SPEC REMARK
CPU 32-Bit RISC CPU (266MHz)
8M SDRAM
4M FLASH (Default) 3,520
fingerprints
MEMORY
8M FLASH (Option) 8,160
fingerprints
Fingerprint sensor Optical
Authentication speed <1 sec.
Scan Area / Resolution 12.9 * 15.2mm / 500 DPI
FRR / FAR 0.1% / 0.001%
TCP/IP, RS-232, Wiegand
Communication Port RS-485 (Option)
Temperature / Humidity -10~50 /
Lower than 90% RH
LCD 122 X 32 Graphic LCD
SIZE 137 X 137 X 50mm
INPUT: Universal AC 100~250V
OUTPUT: DC 12V (Option: DC 24V)
AC / DC Adapter
UL, CSA, CE Approved
RF Card Reader EM Card,
125kHz
Smart Card Reader A-type,
13.56MHz
Options
Door phone

VIRDI 3000 Installation Guide 14
3. Installation Guide
3.1. Product Composition Items
Type Shape Number Usage
1 Set Entrance
Restriction
Product
Power Conversion
Adapter
1 EA (12V~24V)
POWER
Cable
1 EA
POWER Supply
(110V~220V)
**Shape change for
110V
Secure
Plate
1 EA Securing Product
4 EA Securing Plate
2 EA Securing Plate
(Backup)
Securing
Screw
4 EA Securing Product

VIRDI 3000 Installation Guide 15
8-PIN Lock
1 EA Cable
1 EA 2-PIN Door Phone
Cable
HOUSING
&
Terminal
10 EA Terminal
Driver Driving Product
Securing Screws
1 EA
(OPTION)

VIRDI 3000 Installation Guide 16
3.2. Installation Environment Conditions
3.2.1. Environment Conditions
zOnly regulated 110V~220V power must be used. Especially if you are using
emergency power, receive the Manager’s consent.
zThis product was designed for indoor installation. Please avoid direct light
rays, snow, rain, etc.
zAll cables should be buried, so please review properly before installation.
.
zAvoid moist areas with a lot of dust when installing.
zArbitrarily repairing or disassembling the product can result in electrocution or
fires. Only expert technicians should do such jobs.
zExtending the DC (12V~24V) line causes a voltage drop, preventing proper
power supply to the product. Please show caution when installing.

VIRDI 3000 Installation Guide 17
3.3. Main Board Composition
<Figure 3.3.1> main board composition
J105
Wiegand OUT
J106
Wiegand IN J203
LOCK
J301
Door Phone
J251
POWER 12V
J501
Ethernet
Fuse
SW1
Reset Switch J151
Fingerprint
sensor
U1
CPU
J302,303
Key Interface J107
RS485
communication
Lock type setiing switch
SW201, SW202

VIRDI 3000 Installation Guide 18
3.4. PIN Specifications of Each Product Part
<Figure 3.4.1> 8-PIN door lock housing
FUNCTION REMARK
1 DOOR-OUT(+Vin) LOCK control voltage
Powerless connection control (if JP201
removed)
2 LOCK COM
3 GND GROUND
4 INSIDE-OPEN Inner door OPEN switch
5 DOOR MONITOR 0 Door status MONITORING
6 DOOR MONITOR 1 Door status MONITORING
7 DOOR MONITOR 2 Door status MONITORING
8 GND GROUND
<Figure 3.4.2> 2-PIN door phone sound housing
<Figure 3.4.3> 3-PIN power supply housing

VIRDI 3000 Installation Guide 19
3.5. Installation
3.5.1. Installation Process (All)
1) Select the product installation location and the Electric Lock type according to
the fireproof door type.
2) Confirm the locations of the LAN line and main power(110V–220V) and
connect the lines.
3) When connecting the door phone, connect the lines so that the product and
door phone are less than 30m apart.
4) Assemble the 8-PIN Housing using the terminals according to the electric lock
type.
5) Assemble the 2-PIN Housing of the door phone line using the terminals.
6) Secure the secure plate to the wall using the 4 securing screws.
7) Connect the terminals and secure the product to the plate.
8) Supply power, check that the product is functioning, and install the software on
the PC.
3.5.2. Installation Process Order (Detailed)
1) Select the product installation location and the Electric Lock type according to
the fireproof door type.
☞150cm~160cm from the floor is appropriate for the product.
<Figure 3.5.1> product installation position
150cm
–
160cm

VIRDI 3000 Installation Guide 20
☞The electric lock is classified into 4 categories according to the fireproof
door type.
Category Shape Capacity Notes
Input voltage: DC12V
Consumed current: less
than 1A
Power
control
Dead Bolt
Input voltage: DC12V
Electro-
magnetic Lock
Consumed current: less
than 1A
Power
control
Input voltage: DC12V
Consumed current: less
than 1A
Power
control
Electric Strike
Connection point signal
produced
Connection
control
Auto Door
<Figure 3.5.2> electric lock types

VIRDI 3000 Installation Guide 21
2) Confirm the locations of the LAN line and main power (110V–220V) and connect
the lines.
Ensure that the UTP cable allows TCP/IP
communication between the hub and the product using
LAN tools, the RJ-45 connector, and a boot. Once you
are done, use the LAN test equipment to check if the
connection is working properly.
The main power and adapter must be installed inside a
wall or in the inner ceiling.
3) When connecting the door phone, connect the lines so that the product and
door phone are less than 30m apart. Connect to PIN2 for voice communication, and
connect to PIN8 for the inner exit line.
<Figure 3.5.3> door phone connection diagram
Pin8
2PIN cable
(
VOICE line
)
PIN8
(
BK
)
PIN4
(
OR
)
Inner exit si
g
nal line
Pin4
Table of contents
Other VIRDI Touch Terminal manuals