Open window detect function (OWD function)
When the Open Window mode is enabled in the parameter setting, the system will automatically stop heating
when it detects a sudden drop of room temperature (2°C in 15 minutes as default). This is normally caused
when a window or door is opened without turning off the heating device.
The device will return to the previous mode of operation after 30mins, then OP disappear. Press any button
will exit OWD function during the heating off period.
Pair with Host device
Note: Before adding thermostatic radiator valve HT-10R to the app, please make sure you have add the
gateway E-hub.
1) Turn on app, press gateway-- press add sub device—press heater
2) Turn radiator HT-10R off by pressing ON/OFF button, then long press Mbutton until it show a “0 and
signal icon”, then press UP button, when HT-10R display 3 or signal icon stop moving, means code
pairing done. Press ON/OFF button to return, and press again to turn it on.
Parameter setting
Turn off the thermostat, Press and hold Mand UP button for 3s, until it shows the item 01, each press of M
button will go to next item setting, adjust the range by using UP and DOWN button.