manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Voltronic Power
  6. •
  7. Controllers
  8. •
  9. Voltronic Power AVR 8K User manual

Voltronic Power AVR 8K User manual

USER MANUAL
AVR 5K/8K/10K
Automatic Voltage Regulator
Version: 1.2
I. Introduction
Thank you for purchasing this AVR. This AVR is designed to
automatically maintain a constant voltage level to protect
sensitive electronics from brownouts and over voltages.
Equipped with comprehensive information display, it’s easy to
monitor the power status.
Microprocessor control guarantees high reliability
Time delay function eliminates transients that can affect
connected equipment.
Startup countdown time display
Over-voltage, under-voltage, over-heat and over current
protection
Provides surge and spike suppression
Frequency: 50Hz or 60Hz mode
Input and output voltage display for Color display
Load level display
Over load protection
II. Important Safety Caution (SAVE THESE
INSTRUCTION)
To safely operate this AVR, please read and follow all
instructions carefully. Read this manual thoroughly
before attempting to unpack, install, or operate. You
may keep this quick guide for further reference.
CAUTION: The unit is designed only for use under the 50
/60Hz input frequency and pure sine wave environment. Any
other input frequency or waveform will effect the voltage
range and load capability.
CAUTION: Please DO NOT connect the unit to the
environment with direct voltage (DC) or simulated sine
wave.
CAUTION: To prevent the risk of fire or electric shock,
install in a temperature and humidity controlled indoor
area free of conductive contaminants. (See the
specifications for the acceptable temperature and humidity
range.)
III.Product Overview
Front View: Back View:
Color screen display:
1. Color screen display
2. Startup delay time selector
3. Power Switch
4. Handle
5. Input voltage display
6. Output voltage display
7. Over-voltage indicator
8. Under-voltage indicator
9. Frequency information
10. Fault indicator
11. Time delay indicator
12. Load level indicator
13. Overload indicator
14. Output sockets
15. Neutral input terminal
16. Line input terminal
17. Grounding
18. Neutral output terminal
19. Line output terminal (brown)
IV.Installation and Operation
1. Inspection
Remove the unit from its packaging and inspect it for
damage that may have occurred during shipping. If any
damage is discovered, repack the unit and return it to the
place of purchase.
2. Placement
Install the unit in any protected environment that
provides adequate airflow around the unit, and is free
from excessive dust, corrosive fumes and conductive
contaminants. Do not operate this unit in an environment
where the ambient temperature or humidity is high. On
the other hand, place the unit from the monitor at least
20cm to avoid interference.
3. Wall Outlet Connection
Plug the unit into a 3-wire grounded receptacle.
4. Setting Startup Delay Time Switch
Delay : Setting delay time as 3minutes.it’s designed to
avoid damage devices with AC motor from consecutive
starts. It’s perfect to use with devices such as
refrigerators, freezers, air conditioners or dehumidifiers.
Undelay : Setting delay time as 10 seconds. It’s
designed for use with voltage sensitive equipment such
as: personal computers, monitors, inkjet printers,
scanners or faxes. It’s also designed for use with home
appliances such as televisions, stereos, CD/DVD players,
VCRs, modems, and telephone equipment
5. Load connection
The AVR will provide pure power to connected devices.
Simply connect sensitive loads to these receptacles.
6. Turn On/Off
Turn on the unit by pressing the power switch to
“RESET” position. Then, all connected devices
will be powered on.
V. Application
CAUTION: The total power consumption of all equipment
plugged into the AVR must not exceed its capacity. Atotal
load in excess of its capacity will cause the breaker to fault
(blow)
For the capacity of unit, please check the specifications.
The AVR is designed for use with voltage sensitive
equipment such as: a home computer, monitor, inkjet printer,
scanner or fax. It is also designed for use with home
electronics equipment such as television, stereos, CD
players, VCRs, and DVD players, data processing
equipment, modems, typewriters, calculators, and telephone
equipment. When delay time Setting as 3 minutes It’s perfect
to use with devices such as refrigerators, freezers, air
conditioners or dehumidifiers.
When use the AVR with an Uninterruptible Power Supply
(UPS), connect the UPS to the output of this product, then
connect the product to the wall outlet.
VI. Specifications
1. Input Range A
MODEL
A5K-80C3C
A8K-80C3C
A10K-80C3C
CAPACITY
5000VA
8000VA
10000VA
INPUT
Voltage
220 VAC or 230 VAC
Input Range
80 –260 VAC or 80 –270 VAC
Frequency
50 Hz or 60 Hz
OUTPUT
Voltage
220 VAC or 230 VAC
Voltage
Regulation
-10 % ~ + 10%
PHYSICAL
Dimension
(DxWxH)
450 x 210 x 237 (mm)
Net Weight
11.14 kg
14.64 kg
16.53 kg
ENVIRONMENT
Temperature
0-40°C
Humidity
0-90% relative humidity (non-condensing)
2. Input Range B
MODEL
A5K-
100C3C
A8K-
100C3C
A10K-
100C3C
CAPACITY
5000VA
8000VA
10000VA
INPUT
Voltage
220 VAC or 230 VAC
Input Range
100 –260 VAC or 100 –270 VAC
Frequency
50 Hz or 60 Hz
OUTPUT
Voltage
220 VAC or 230 VAC
Voltage
Regulation
-10 % ~ + 10%
PHYSICAL
Dimension
(DxWxH)
450 x 210 x 237 (mm)
Net Weight
11.06 kg
14.42 kg
16.34 kg
ENVIRONMENT
Temperature
0-40°C
Humidity
0-90% relative humidity (non-condensing)
3. Input Range C
MODEL
A5K-
140C3C
A8K-
140C3C
A10K-
140C3C
CAPACITY
5000VA
8000VA
10000VA
INPUT
Voltage
220 VAC or 230 VAC
Input Range
140 –260 VAC or 140 –270 VAC
Frequency
50 Hz or 60 Hz
OUTPUT
Voltage
220 VAC or 230 VAC
Voltage
Regulation
-10 % ~ + 10%
PHYSICAL
Dimension
(DxWxH)
450 x 210 x 237 (mm)
Net Weight
10.96 kg
14.31 kg
15.95 kg
ENVIRONMENT
Temperature
0-40°C
Humidity
0-90% relative humidity (non-condensing)

This manual suits for next models

11

Other Voltronic Power Controllers manuals

Voltronic Power SCC-MPPT Series User manual

Voltronic Power

Voltronic Power SCC-MPPT Series User manual

Voltronic Power AVR 5K User manual

Voltronic Power

Voltronic Power AVR 5K User manual

Popular Controllers manuals by other brands

Hach SC4500 User instructions

Hach

Hach SC4500 User instructions

Vanderbilt ACT365 VCU Installation and operating instructions

Vanderbilt

Vanderbilt ACT365 VCU Installation and operating instructions

Rockwell Automation Allen-Bradley 1512A user manual

Rockwell Automation

Rockwell Automation Allen-Bradley 1512A user manual

Vais Technology SoundLinQ3 SL3sat owner's manual

Vais Technology

Vais Technology SoundLinQ3 SL3sat owner's manual

Dahua DHI-ARC3008C user manual

Dahua

Dahua DHI-ARC3008C user manual

Siemens Acvatix SAS Series Basic documentation

Siemens

Siemens Acvatix SAS Series Basic documentation

SOMFY animeo IB+ 1860209 installation guide

SOMFY

SOMFY animeo IB+ 1860209 installation guide

ABB ACS880-37 Hardware manual

ABB

ABB ACS880-37 Hardware manual

Holley 551-102 Full user manual

Holley

Holley 551-102 Full user manual

gefran SIEIDrive ADV100 Functions description  and parameters list

gefran

gefran SIEIDrive ADV100 Functions description and parameters list

Cisco SFS 3504 installation guide

Cisco

Cisco SFS 3504 installation guide

Omron SYSMAC CJ1-M brochure

Omron

Omron SYSMAC CJ1-M brochure

HP StorageWorks P2000 Replacement instructions

HP

HP StorageWorks P2000 Replacement instructions

EuroLite LED C-1 user manual

EuroLite

EuroLite LED C-1 user manual

heat-timer DIGI-SPAN VSP Elite Installation and operation instructions

heat-timer

heat-timer DIGI-SPAN VSP Elite Installation and operation instructions

WAREMA BACnet 4M230.8I AP installation instructions

WAREMA

WAREMA BACnet 4M230.8I AP installation instructions

OEG KMS-D manual

OEG

OEG KMS-D manual

Pacific Power Source UPC-3 Operation manual

Pacific Power Source

Pacific Power Source UPC-3 Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.