WARNING
IMPORTANT: NEVER attempt to do any work without shutting o the electricity.
1. Read all instructions before installing.
2. System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local regulations.
3. Place the wall switch in the“OFF”position.
4. Go to the main fuse box, or circuit breaker. Unscrew the fuse(s) or switch “OFF” the circuit breaker switch(es) that control the power to the
space that you are working on.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out
or broken. Failure to follow this instruction may invalidate the UL listing of this xture.
CAUTION: NOT FOR USE IN SWIMMING POOL OR SPA APPLICATIONS.
NOT FOR USE IN SALT WATER APPLICATIONS (doing so will void the luminaire nish warranty)
NOTE: Leave enough extra cable to be able to freely remove xture from water for servicing. Do not pull on the cable as this may cause the liquid
tight seal on the xture to break which will void the warranty and result in possible leakage.
NOTE: Do not loosen or remove the liquid tight connector in the back of the xture. This will damage the factory installed seal and result in
possible leakage.
NOTE: End of underwater cable must be potted to prevent moisture from entering cable and consequently entering luminaire. Connection or
splicing of cable must be made above water line and at least 4’ from water edge. This luminaire comes with 30 feet of cable to facilitate installa-
tion away from water.
NOTE: This xture must be submerged in a body of water with a maximum depth of 3 feet.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les règlements locaux.
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
- Toujours mettre le fusible ou le disjoncteur en position arrêt dans la pièce ou des travaux électriques sont prévus
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez
pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler
l’homologation UL du luminaire.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e instalación de esta lámpara.
- Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las normas locales.
- Coloque el interruptor de la pared en la posición “OFF”(APAGADO).
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de alimentación principal
en la posición “OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice
piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación UL esta lámpara.
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. DEC 2018
waclighting.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
1
THIS INSTRUCTION APPLYS TO THE MODEL(S) BELOW: 5511 (FIG.1)
INSTALLATION INSTRUCTIONS
Underwater Spot Light
5511
FIG.1
WAC Lighting retains the right to modify the design of our products at any time as part of the company’s continuous improvement program. DEC 2018
waclighting.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
2
INSTALLATION ACCESSORIES:
INSTALLATION WITHOUT AIMING BRACKET (FIG.3):
1. Place xture at desired location within fountain, pond
or water feature.
2. Place rocks around xture to keep it in place.
3. Route lead wire to 12V power source and make connection.
Use approved gel lled wire nuts.
4. Turn on 12V power supply and check for proper operation.
1. Place xture at desired location within fountain, pond or
water feature.
2. Place rocks around xture to keep it in place.
3. Route lead wire to 12V power source and make connection.
Use approved gel lled wire nuts.
4. Turn on 12V power supply and check for proper operation.
Outdoor Rated Wire Nut
Qty: 2pcs
Aiming Bracket Mounting
Screws and Anchors
Qty: 3pcs
Detachable Shroud
Qty: 1pc
FIG.3
Connect to 12V Transformer Connect to 12V Transformer
Without Aiming Bracket
Factory Sealed
Liquid-tight Connector
With Aiming Bracket
Aiming Bracket
INSTALLATION WITH AIMING BRACKET (FIG.4):
1. Place xture at desired location within fountain, pond or water
feature. Holes in bottom of aiming bracket can be used to attach
bracket to bottom/side surface if needed.
Using the holes on the aiming bracket to mark the three mounting
points. Using the marks to drill holes and insert the anchors. Mount
the xture onto the anchors by using the mounting screws.
(Mounting screws and anchors are provided.)
2. Loosen thumb screws on both sides of the aiming bracket, adjust
xture to desired angle then tighten thumb screws rmly.
3. Route lead wire to 12V power source and make connection.
Use approved gel lled wire nuts.
4. Turn on 12V power supply and check for proper operation.
5. To re-adjust xture angle, turn o power and repeat Step 2.
FIG.4
Fixture With Aiming Bracket
Thumb Screw (on both sides)
Mounting Screws (Provided)
Screw Anchors (Provided)
Detachable Shroud
Hole Markings
X
XX
INSTALLATION INSTRUCTIONS
Underwater Spot Light
5511
WAC Lighting retains the right to modify the design of our products at any time as part of the company’s continuous improvement program. DEC 2018
waclighting.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
3
ACCESSORIES LENS ACCESSORY (FIG.5):
Frosted, red, blue, green and amber lens accessories are used to alter
the spectrum and distribution of the light coming out of the xture.
INSTALLATION: Place the lens in between the xture and the shroud.
Tighten the thumb screw on the shroud to secure the lens in place.
FIG.5
LENS-20
Detachable Shroud
INSTALLATION INSTRUCTIONS
Underwater Spot Light
5511

Popular Underwater Lighting manuals by other brands

Backscatter Mini Flash MF-1 instruction manual

Backscatter

Backscatter Mini Flash MF-1 instruction manual

Shadow-Caster SCM-PD-PLUS installation instructions

Shadow-Caster

Shadow-Caster SCM-PD-PLUS installation instructions

Kripsol PH300.C Manual for the installation, use and maintenance

Kripsol

Kripsol PH300.C Manual for the installation, use and maintenance

LIGMAN BORNHOLM 2 installation manual

LIGMAN

LIGMAN BORNHOLM 2 installation manual

GRALmarine Vpro manual

GRALmarine

GRALmarine Vpro manual

Ros SEASTAR Operation and maintenance manual

Ros

Ros SEASTAR Operation and maintenance manual

LIGMAN FUNEN 2 installation manual

LIGMAN

LIGMAN FUNEN 2 installation manual

UNDERWATER LIGHTS LIMITED QT-75 Retro manual

UNDERWATER LIGHTS LIMITED

UNDERWATER LIGHTS LIMITED QT-75 Retro manual

LIGMAN OR-60895 installation manual

LIGMAN

LIGMAN OR-60895 installation manual

hentech HT023C instruction manual

hentech

hentech HT023C instruction manual

hentech HT001BL-T1 instruction manual

hentech

hentech HT001BL-T1 instruction manual

Reef Images Focus Light instructions

Reef Images

Reef Images Focus Light instructions

Oase Lunaqua 2 Directions for use

Oase

Oase Lunaqua 2 Directions for use

Certikin PU9CS Installation

Certikin

Certikin PU9CS Installation

HEISSNER U 130-T Instructions for use

HEISSNER

HEISSNER U 130-T Instructions for use

Oceanled Sport Series Quick install guide

Oceanled

Oceanled Sport Series Quick install guide

Pahlen LED 300A Classic manual

Pahlen

Pahlen LED 300A Classic manual

Brilix P100 user guide

Brilix

Brilix P100 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.