Universal Control Unit for Powder Spray Guns
EPG S2, EPG S2 FM
Translation of the Original Operating Manual
0102 II3(2)DIP6480°C +
For professional use.
Always observe the information in this manual, particularly the safety
instructions and the warning instructions. Store the manual in a safe place. Edition: 10/2022


Operating manual Universal Control Unit for Powder Spray Guns EPG S2, EPG S2 FM
Table of Contents
Order number 2317574 | Edition 10/2022 3
TABLE OF CONTENTS
1 About these Instructions 5
1.1 Preface 5
1.2 Warnings, Notices and Symbols in these Instructions 5
1.3 General Characters and Symbols 5
1.4 Languages 6
1.5 Abbreviations 6
1.6 Terminology for the Purpose of this Manual 6
2 Using in Accordance with the Instructions 8
2.1 Device Type 8
2.2 Type of Use 8
2.3 For Use in Potentially Explosive Areas 8
2.4 Processible Working Materials 8
2.5 Misuse 8
3 Identification 9
3.1 Explosion Protection Identification 9
3.2 Permissible device combinations 9
3.3 Type Plate 10
4 Basic Safety Instructions 11
4.1 Safety Instructions for the Operator 11
4.1.1 Electrical Devices and Equipment 11
4.1.2 A Safe Work Environment 11
4.1.3 Personnel Qualifications 12
4.2 Safety Instructions for the Personnel 12
4.2.1 Personal Safety Equipment 12
4.2.2 Safe Handling of WAGNER Powder Spray Devices 13
4.2.3 Grounding the Device 13
4.2.4 Product Hoses 13
4.2.5 Electrical Connection Cables 14
4.2.6 Cleaning and Flushing 14
4.2.7 Maintenance and Repair 14
4.2.8 Protective and Monitoring Equipment 15
4.3 Safety Features 15
5 Description 17
5.1 Applications 17
5.2 Extent of Delivery 17
5.3 Technical Data 17
5.4 Operating Elements 19
5.4.1 Display Elements on Front Side 19
5.4.2 Connections on the Rear Side of the EPG S2 20
5.4.3 Connections on the Rear Side of the EPG S2 FM 21
5.4.4 CAN Bus Connection on the Rear Side 21
5.5 Accessories 22
6 Assembly and Commissioning 23
6.1 Training of Assembly/Commissioning Personnel 23
6.2 Storage Conditions 23
6.3 Installation Conditions 23
6.4 Connecting the Automatic Guns 24
6.5 Connecting the Manual Guns 25

Operating manual Universal Control Unit for Powder Spray Guns EPG S2, EPG S2 FM
Table of Contents
4 Order number 2317574 | Edition 10/2022
6.6 Connection diagram in the rack 25
6.7 Grounding 27
6.7.1 Grounding the powder coating system 27
6.8 Device settings 28
6.8.1 CAN Bus Baud Rate Setting 29
6.8.2 CAN bus node ID setting 29
7 Operation 30
7.1 Training the Operating Personnel 30
7.2 Preparations for Commissioning 30
7.2.1 Tasks 30
7.2.2 Controllable spray guns 30
7.2.3 Gun cable lengths 30
7.2.4 Control Functions on EPG S2 Control Unit 30
7.2.5 Diagnosis and Monitoring 33
7.2.6 Emergency Operation 33
8 Cleaning and Maintenance 35
8.1 Cleaning 35
8.1.1 Cleaning Personnel 35
8.1.2 Cleaning Procedures 35
8.2 Maintenance 35
8.2.1 Maintenance Personnel 35
8.2.2 Maintenance Instructions 36
8.2.3 Safety Checks 36
8.2.4 Maintenance Procedures 36
9 Troubleshooting and Rectification 37
9.1 Faults 37
10 Inspections in Accordance with DIN EN 50177: 2009 38
10.1 Abbreviations 38
10.2 Overview Table 39
11 Disassembly and Disposal 41
11.1 Disassembly 41
11.2 Disposal 41
12 Accessories 42
12.1 Accessories 42
13 Spare Parts 43
13.1 How to Order Spare Parts 43
13.2 Notes on the Use of Spare Parts 43
13.3 EPG S2 control unit 44
14 Declaration of Conformity 45
14.1 EU Declaration of Conformity 45
14.2 FM Control Document 45

Operating manual Universal Control Unit for Powder Spray Guns EPG S2, EPG S2 FM
1 About these Instructions
Order number 2317574 | Edition 10/2022 5
1 ABOUT THESE INSTRUCTIONS
1.1 PREFACE
The operating manual contains information about safely operating, maintaining, cleaning
and repairing the device. The operating manual is part of the device and must be available
to the operating and service personnel.
The device may only be operated by trained personnel and in compliance with this
operating manual. Operating and service personnel should be instructed according to the
safety instructions.
This equipment can be dangerous if it is not operated according to the instructions in this
operating manual.
1.2 WARNINGS, NOTICES AND SYMBOLS IN THESE INSTRUCTIONS
Warning instructions in this manual highlight particular dangers to users and to the device
and state measures for avoiding the hazard.
These warning instructions fall into the following categories:
DANGER Immediate risk of danger.
Non-observance will result in death or serious injury.
WARNING Potential danger.
Non-observance may result in death or serious injury.
CAUTION Potentially dangerous situation.
Non-observance may result in minor injury.
NOTICE Potentially dangerous situation.
Non-observance may result in damage to property.
Info Provides information about particular characteristics and how to
proceed.
Explanation of warning notice:
WARNING
This notice warns you of a danger!
Possible consequences of not observing the warning notice.
4The measures for preventing the hazard and its consequences.
1.3 GENERAL CHARACTERS AND SYMBOLS
The characters and symbols in this operating manual indicate the following:
üRequirement that must be fulfilled before an action can be performed.
1. Step 1 of an action to be performed with several action steps.
4Second level action step
2. Step 2
ðIntermediate result of an action
ðResult of a complete action
4Action to be performed with an action step
1. Numbered list, first level
– Numbered list, second level

Operating manual Universal Control Unit for Powder Spray Guns EPG S2, EPG S2 FM
1 About these Instructions
6 Order number 2317574 | Edition 10/2022
– Non-numbered list, first level
– Non-numbered list, second level
= cross-reference on page
♦ = wearing parts
⋆ = included in service set
● = not part of the standard equipment but available as a special accessory
1.4 LANGUAGES
The operating manual is available in the following languages:
Original operating manual
Language Order no.
German 2317573
Translation of the original operating manual
Language Order no. Language Order no.
English 2317574 Russian 2334207
French 2317575 Chinese 2335799
Italian 2317576 Hungarian 2338270
Spanish 2358652 Czech 2348860
Danish 2371619 Swedish 2371624
Portuguese 2392066 Bulgarian 2392690
Romanian 2397397 Slovakian 2400614
Turkish 2400843 Polish 2410735
Finnish 2412455 Norwegian 2414214
Croatian 2417088 Dutch 2423634
Slovenian 2429132
Additional languages upon request or at: www.wagner-group.com
1.5 ABBREVIATIONS
Order no. Order number
ET Spare part
K Marking in the spare parts lists
Pos Position
Stk Number of pieces
-- Item not available as spare part
/ Item does not exist
1.6 TERMINOLOGY FOR THE PURPOSE OF THIS MANUAL
Cleaning
Cleaning Manual cleaning of devices and device parts with cleaning agent.
Flushing Internal flushing of paint-wetted parts with compressed air.

Operating manual Universal Control Unit for Powder Spray Guns EPG S2, EPG S2 FM
1 About these Instructions
Order number 2317574 | Edition 10/2022 7
Personnel qualifications
Trained person Is instructed in the tasks assigned to him/her, the potential risks associ-
ated with improper behavior as well as the necessary protective devices
and measures.
Electrically
trained person
Is instructed by an electrician about the tasks assigned to him/her, the
potential risks associated with improper behavior as well as the neces-
sary protective devices and measures.
Electrician Can assess the work assigned to him/her and detect possible hazards
based on his/her technical training, knowledge and experience in rele-
vant provisions.
Skilled person in
the context of
DGUV209‑052
A person who, based on his/her technical training, experience and re-
cent vocational experience, has sufficient technical knowledge in the
area of electrostatic coating and is familiar with the relevant and gener-
ally accepted rules of technology so that he/she can inspect and assess
the status of devices and coating systems based on workplace safety.
Additional requirements for skilled persons can also be found in
TRBS1203(2010/amendment 2012): Expert knowledge in the areas of
protection against excessive pressure, electrical hazards and explosion
protection (where applicable).

Operating manual Universal Control Unit for Powder Spray Guns EPG S2, EPG S2 FM
2 Using in Accordance with the Instructions
8 Order number 2317574 | Edition 10/2022
2 USING IN ACCORDANCE WITH THE INSTRUCTIONS
2.1 DEVICE TYPE
Universal control unit for controlling two electrostatic manual and automatic powder spray
guns
2.2 TYPE OF USE
The EPG S2 control unit is intended for controlling electrostatic manual and automatic
powder spray guns of types A-P (2 mJ) according to DIN EN 50177.
The device may only be operated under the following conditions:
4Use the device only to work with the materials recommended by WAGNER.
4Only operate the device as a whole.
4Do not deactivate safety fixtures.
4Use only WAGNER original spare parts and accessories.
4The operating personnel must be trained on the basis of this operating manual.
4Follow the instructions in the operating manual.
2.3 FOR USE IN POTENTIALLY EXPLOSIVE AREAS
The EPG S2 control unit is intended for use with powder spray guns of types A-P up to 2 mJ
in accordance with the type examination PTB 12 ATEX 5001.
The EPG S2 control unit may be used in the dust explosion zone (zone 22) under the
following conditions:
– Control unit correctly fitted and connections on rear correctly protected with associated
cover, which can only be opened again with a tool.
– Unused electrical connections are sealed with protective caps.
2.4 PROCESSIBLE WORKING MATERIALS
– Types of powder which can be charged electrostatically
– Metallic powder
Info
Contact your local WAGNER dealer and the lacquer manufacturer if you encounter
application problems.
2.5 MISUSE
Misuse can lead to physical injury and/or property damage! Special attention must be paid
that:
4No liquid coating products, e.g. solvents or water-based lacquers, are processed.
4No food, medicine or cosmetics are processed.

Operating manual Universal Control Unit for Powder Spray Guns EPG S2, EPG S2 FM
3 Identification
Order number 2317574 | Edition 10/2022 9
3 IDENTIFICATION
3.1 EXPLOSION PROTECTION IDENTIFICATION
The device is suited for use in potentially explosive areas, in accordance with Test Certificate
PTB12ATEX5001.
Device Type Universal control unit EPG S2
Manufacturer Wagner International AG
9450 Altstätten
Switzerland
0102 II3(2)DIP6480°C
CE European Communities
0102 Number of notified body which issues the recognition of quality
assurance in production.
Ex Symbol for explosion protection
II Device class II
3 Category 3 (zone 22)
(2) Impact on equipment of category 2
D Ex-atmosphere dust
IP 64 Protection class IP64
80°C Temperature class: maximum surface temperature < 80°C;
176°F
3.2 PERMISSIBLE DEVICE COMBINATIONS
WARNING
Incorrect use!
Risk of injury and damage to the device.
4Only connect original WAGNER spray guns to the EPG S2 control unit.
The following powder spray guns may be connected to the EPG S2:
Manual spray guns
Corona spray gun PEM-X1, PEM-C3, PEM-C4 HiCoat
PEM-C4-Ergo
Automatic spray guns
Corona spray gun PEA-C3, PEA-C4, PEA-X1, PER-X1
PEA-C3XL, PEA-C4XL
Tribo spray gun PEA-T3
PEA-T3XL
Older or other gun types may only be connected to the control unit after first checking their
suitability with WAGNER.
For permissible device combinations for the USA and Canada, see FM Control Document
[845].

Operating manual Universal Control Unit for Powder Spray Guns EPG S2, EPG S2 FM
3 Identification
10 Order number 2317574 | Edition 10/2022
3.3 TYPE PLATE
P_05502
1
2
4
5
6
7
8
3
Year of build:
Baujahr:
B
Für den Betrieb in der Zone 22
müssen alle Anschlüsse mit Stecker
oder Schutzkappe versehen sein.
Prim. Fuse
Sicherung
1.0 AT
(slow blow)
Spraygun
Sprühpistole
IN CAN Bus OUT
Data and Interlock
Daten und Verriegelung
Ausgang zur Pistole
Output to gun
I max. 0,9 A
U max. 22 Vpp
Dosage air
Dosierluft
Feeding air
Förderluft
Atomizing air
Zerstäuberluft
Mains power IN / OUT
Netz EIn / Ausgang
6.....8 bar
87..116 psi
Clean and
dry air
Saubere und
trockene Luft
6.5.2 (ISO 8573.1)
Do NOT disconnect under voltage!
NICHT unter Spannung trennen!
Air input
Lufteingang
Dosage air
Dosierluft
Feeding air
Förderluft
Atomizing air
Zerstäuberluft
A
A AB B
Type / Typ:
Serial No.:
Serie Nr.:
Voltage:
Spannung:
Line Power:
Eingangsleistung:
Prot. Class:
Schutzklasse:
EPG S2
90-250 VAC 47-63 Hz
max. 60 W
IP 64
For operation all ports must be fitted
with a plug or the protection cap.
CH 9450 Altstätten
Made in Switzerland
II 3(2)D IP64 80ºC
Tested / Geprüft EN50050-2, EN50177
BS EN50050-2, BS EN50177
PTB 12 ATEX 5001 / CSAE 21 UKEX 5714
Wagner International AG
0102
0518
Service
Port
CAN
Address
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
1 2 3 4
Type / Typ:
Serial No.:
Serie Nr.:
Voltage:
Spannung:
Line Power:
Eingangsleistung:
Prot. Class:
Schutzklasse:
EPG S2
90-250 VAC 47-63 Hz
max. 60 W
IP 64
CH 9450 Altstätten
Made in Switzerland
II 3(2)D IP64 80ºC
Tested / Geprüft EN50050-2, EN50177
BS EN50050-2, BS EN50177
PTB 12 ATEX 5001 / CSAE 21 UKEX 5714
Wagner International AG
0102
0518
Type plate for EPG S2
1 Manufacturer 5 Serial number
2 Identification 6 Input voltage
3 Test center 7 Input power
4 Device Type 8 Protection class
P_05503
1
2
4
5
6
7
8
3
Serial No. / Year of build:
Serie Nr. / Baujahr:
B
Prim. Fuse
Sicherung
1.0 AT
(slow blow)
Spraygun
Sprühpistole
IN CAN Bus OUT
Data and Interlock
Daten und Verriegelung
Ausgang zur Pistole
Output to gun
I max. 0,9 A
U max. 22 Vpp
Dosage air
Dosierluft
Feeding air
Förderluft
Atomizing air
Zerstäuberluft
Mains power IN / OUT
Netz EIn / Ausgang
Air input
Lufteingang
Dosage air
Dosierluft
Feeding air
Förderluft
Atomizing air
Zerstäuberluft
A
A AB B
Overvoltage Category II
and pollution Degree 2
FM approved for CL II, Div 2 Grps E, F, & G
Use in accordance with
control document:
2309729
Made in Switzerland
CH 9450 Altstätten
Voltage:
Spannung:
Line Power:
Eingangsleistung:
90-250 VAC 47-63 Hz
max. 65 W
Type / Typ: EPG S2 FM
For operation all ports must be fitted
with a plug or the protection cap.
Controller is suitable for Class II,
Division 2, Hazardous (Classified)
locations.
Do NOT connect or disconnect
when ENERGIZED !
Ambient temp range 5C to 45C T5
Wagner International AG
6.....8 bar
87..116 psi
Clean and
dry air
Saubere und
trockene Luft
6.5.2 (ISO 8573.1)
Service
Port
CAN
Address
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
1 2 3 4
Serial No. / Year of build:
Serie Nr. / Baujahr:
Overvoltage Category II
and pollution Degree 2
FM approved for CL II, Div 2 Grps E, F, & G
Use in accordance with
control document:
2309729
Made in Switzerland
CH 9450 Altstätten
Voltage:
Spannung:
Line Power:
Eingangsleistung:
90-250 VAC 47-63 Hz
max. 65 W
Type / Typ: EPG S2 FM
Ambient temp range 5C to 45C T5
Wagner International AG
Type plate for EPG S2 FM
1 Manufacturer 5 FM testing
2 Device Type 6 Ambient temperature
3 Input voltage 7 Use according to the control docu-
ment
4 Input power 8 Serial number

Operating manual Universal Control Unit for Powder Spray Guns EPG S2, EPG S2 FM
4 Basic Safety Instructions
Order number 2317574 | Edition 10/2022 11
4 BASIC SAFETY INSTRUCTIONS
4.1 SAFETY INSTRUCTIONS FOR THE OPERATOR
4Keep this operating manual at hand near the device at all times.
4Always follow existing regulations concerning occupational safety and accident
prevention regulations.
4.1.1 Electrical Devices and Equipment
Danger of electric shock!
Danger to life from electric shock:
4Place and operate device in accordance with the existing safety requirements with
regard to the operating mode and ambient influences.
4May only be maintained by skilled electricians or under their supervision. With open
housings, the mains voltage poses a danger.
4Operate device in accordance with the safety regulations and electrotechnical
regulations.
4Do not disconnect any plug connections during operation.
4Label plug connections with the warning "Do not disconnect when energized".
4Must be repaired immediately in the event of problems.
4Decommission if device poses a danger or is damaged.
4Must be de-energized before work is commenced.
4Secure the device against being switched back on without authorization.
4Inform personnel about planned work.
4Observe electrical safety regulations.
4Ground all devices to a common grounding point.
4Only operate the device with a properly installed socket with a protective ground wire
connection.
4Keep liquids away from electrical devices.
4.1.2 A Safe Work Environment
Danger due to dust formation!
Severe or fatal injuries due to explosion danger or inhalation, swallowing or contact with the
skin or eyes.
4The floor of the work area must be electrostatically conductive (measurement in
accordance with EN1081:2018+A1:2020 or EN61340-4-1:2004+A1:2015).
4In the spray booth, coating may only be performed with correctly designed and locked
technical ventilation.
4Make sure that grounding and potential equalization of all system parts is reliably and
permanently in effect and that they withstand the loads to be expected (e.g.
mechanical, corrosion).
4Make sure that the personal protective equipment (see chapter Personal Protective
Equipment [812]) is present and being used.
4Make sure that all people within the work area wear static dissipative shoes. The
footwear must correspond to EN20344. The measured insulation resistance must not
exceed 100MΩ.

Operating manual Universal Control Unit for Powder Spray Guns EPG S2, EPG S2 FM
4 Basic Safety Instructions
12 Order number 2317574 | Edition 10/2022
4Protective clothing including gloves, must correspond to EN1149-5. The measured
insulation resistance must not exceed 100MΩ.
4Ensure that there are no ignition sources such as naked flames, sparks, glowing wires,
or hot surfaces in the spray booth. Do not smoke.
4A suitable system for suppressing fire and explosion must be installed.
4The powder release must be electrically interlocked with the connected technical
ventilation of the spray system.
4Excess coating product (overspray) must be collected up safely.
Accumulations of powder in the spray booth is to be avoided. Set the parameters of the
floor cleaning and manually clean the spray booth as needed.
4Ensure that maintenance and safety checks are performed regularly.
4In case of defects, immediately shut down the device or system and repair before
switching back on.
Accumulations of powder are to be removed before switching the system back on.
4The operator/responsible person must ensure that an average concentration of powder
lacquer in the air of 50% of the lower explosion limit (max. permitted powder/air
concentration) is not exceeded. If there is no reliable lower explosion limit value, the
average concentration of 20g/m³ must not be exceeded.
4.1.3 Personnel Qualifications
Danger due to incorrect use of device!
Risk of death due to untrained personnel.
4Ensure that the operating personnel has been instructed by the operator in accordance
with the operating manual and the operating instructions. The device must only be
operated, maintained and repaired by trained personnel. Refer to the operating
instructions for information about the required personnel qualifications.
4.2 SAFETY INSTRUCTIONS FOR THE PERSONNEL
4Always observe the information in this manual, particularly the safety instructions and
the warning instructions.
4Always follow existing regulations concerning occupational safety and accident
prevention regulations.
Danger due to high-voltage field!
Danger to life from malfunction of active implants.
4Persons belonging to a risk group according to EMF guideline 2013/35/EU (e.g., carriers
of active implants), must not enter the high-voltage area.
4.2.1 Personal Safety Equipment
Danger due to dust formation!
Serious or fatal injuries due to inhalation, swallowing or contact with the skin or eyes.
4Observe the processing regulations laid down by the manufacturer of the powder
lacquer being used, when preparing or processing the powder.
4Take note of the manufacturer’s notification and the relevant environmental protection
regulations when disposing of powder lacquers.
4Take the specified protective measures, in particular wear safety goggles, protective
clothing and gloves, as well as skin protection cream if necessary.
4Use a mask or breathing apparatus if necessary.

Operating manual Universal Control Unit for Powder Spray Guns EPG S2, EPG S2 FM
4 Basic Safety Instructions
Order number 2317574 | Edition 10/2022 13
4For sufficient health and environmental protection, only operate the device with
technical ventilation (extraction) switched on.
4.2.2 Safe Handling of WAGNER Powder Spray Devices
Danger due to dust formation!
4Do not point spray guns at people.
4Do not spray device parts using electrostatic equipment.
4Before any work on the device, in the event of work interruptions and malfunctions:
4Switch off the energy/compressed air supply.
4Relieve pressure on spray gun and device.
4Secure the spray gun against actuation.
4Disconnect the control unit from the mains.
4In the event of functional faults, remedy the fault as described in the chapter on
troubleshooting.
4Carry out the work steps in accordance with the chapter on pressure relief in the
operating manual of the corresponding device:
4If a prompt for pressure relief is given.
4If coating work is interrupted or stopped.
4Before the device is externally cleaned, checked or serviced.
4Before the spray nozzle is installed or cleaned.
4.2.3 Grounding the Device
Danger due to electrostatic charge!
Explosion hazard and damage to the device.
The electrostatic charge may, in certain cases, give rise to electrostatic charges on the device.
Flames or sparks can form during discharge.
Correct grounding of the entire coating system prevents electrostatic charges:
4Ensure that all devices and tanks are grounded before each coating process.
4All conductive components of the system, such as floors, walls, ceilings, barriers,
transport equipment, work pieces, powder tanks, moving devices or structural parts in
the spray area, with the exception of parts under high voltage during operation, must
be connected to the grounding system.
Parts of the spray booth must be grounded.
4Ensure that all persons inside the working area are grounded, e.g., that they are
wearing static dissipative shoes.
4Grounding cables must be checked regularly to ensure that they are serviceable (see EN
60204).
4.2.4 Product Hoses
Danger due to damaged product hoses!
The product hose may cause dangerous injuries.
4Use only an original WAGNER powder hose.
4Make sure that the hoses are laid only in suitable places. Hoses should not be laid in the
following places under any circumstances:
4in high traffic areas

Operating manual Universal Control Unit for Powder Spray Guns EPG S2, EPG S2 FM
4 Basic Safety Instructions
14 Order number 2317574 | Edition 10/2022
4on sharp edges
4on moving parts
4on hot surfaces
4Ensure that the hoses are never run over by vehicles (e.g., fork lifts), or that the hoses
are never put under pressure from the outside in any other way.
4Ensure that the hoses are never kinked. Observe maximum bending radii.
4Ensure that no work is ever performed with a damaged hose.
4Make sure that the hoses are never used to pull or move the device.
4.2.5 Electrical Connection Cables
Risk caused by improperly laid cables!
Risk of injury and damage to the device.
4Properly lay connection cables and check them regularly.
4Immediately replace damaged connection cables.
4Ensure that no work is ever performed with a damaged connection cable.
4Do not lay connection lines on travel paths of forklifts or through doors/gates.
4Do not lay connection lines in the area of walkable hallways or paths to avoid the risk of
tripping.
4.2.6 Cleaning and Flushing
Danger due to cleaning and flushing!
Explosion hazard and damage to the device.
4Before starting cleaning or any other manual work, the high voltage in the spray area
must be shut down and locked to prevent it from being switched back on.
4Lock the compressed air supply and decompress the device.
4Secure the device against being switched back on without authorization.
4Use only electrically conducting and grounded tanks for cleaning fluids.
4Preference should be given to non-ignitable cleaning fluids.
4Ignitable cleaning liquids may only be used if all high-voltage parts are discharged to a
discharge energy of less than 0.24mJ after shutting off the high voltage before these
parts can be reached. Most ignitable solvents have an ignition power in the range of
0.24mJ, corresponding to 60nC.
4The flash point of the cleaning agents must be at least 15K over the ambient
temperature.
4Note the details provided by the powder lacquer manufacturer.
4To correct for dust deposits, only mobile industrial vacuums of type1 may be used (see
EN60335-2).
4Take measures for workplace safety (see Chapter "A Safe Work Environment").
4.2.7 Maintenance and Repair
Danger due to improper maintenance and repair!
Danger to life and equipment damage.
4Only a WAGNER service center or a specially trained person may carry out repairs and
replace parts.

Operating manual Universal Control Unit for Powder Spray Guns EPG S2, EPG S2 FM
4 Basic Safety Instructions
Order number 2317574 | Edition 10/2022 15
4Repair or replacement of devices or parts of devices are only allowed to be performed
outside the hazard area by qualified personnel.
4Use only WAGNER original spare parts and accessories.
4WAGNER assumes no liability for changes to the product made by the operating
company without the knowledge of WAGNER. Any adjustments to the documentation
and the market release are the responsibility of the operating company.
4Only repair and replace parts that are listed in the chapters "Accessories" and "Spare
Parts" and that are assigned to the device.
4Do not use any defective components.
4Before all work on the device and in the event of work interruptions:
4Switch off the energy and compressed air supply.
4Relieve pressure on spray gun and device.
4Secure the spray gun against actuation.
4Observe the operating and service manual for all work.
4.2.8 Protective and Monitoring Equipment
Danger due to removal of protective and monitoring equipment!
Danger to life and equipment damage.
4Protective and monitoring equipment must not be removed, modified or rendered
unusable.
4Regularly check for perfect functioning.
4If defects are detected on protective and monitoring equipment, the system must not
be operated until these defects are remedied.
4.3 SAFETY FEATURES
Plates bearing information for the user have been attached to the work openings of the
powder coating booth.
The plate size corresponds to standard series Ø100mm (3.94inches).
The label plates, which must be attached, are shown below:
Forbidden for persons with a cardiac
pacemaker!
Forbidden for unauthorized persons!
Smoking, fire, and open flames are pro-
hibited!
Danger of crushing! Risk of tripping!
High voltage!
In the control cabinet:
(25mm; 0.98inch)
Voltage before main switch
Explosive atmosphere!

Operating manual Universal Control Unit for Powder Spray Guns EPG S2, EPG S2 FM
4 Basic Safety Instructions
16 Order number 2317574 | Edition 10/2022
Follow the instructions in the operating
manual!
Wear electrostatically conductive
footwear!

Operating manual Universal Control Unit for Powder Spray Guns EPG S2, EPG S2 FM
5 Description
Order number 2317574 | Edition 10/2022 17
5 DESCRIPTION
5.1 APPLICATIONS
The EPG S2 control unit is used to supply air and voltage to two WAGNER manual or
automatic powder spray guns, in Corona or Tribo versions. The control unit has no operating
elements; various operating statuses are simply displayed.
The module is operated with a superordinate controller (e.g. PLC) from which it receives the
necessary information.
The interface between the EPG S2 and master controller takes place by means of the
CANopen.
5.2 EXTENT OF DELIVERY
Stk Order no. Designation
1 2316991 EPG S2
1 2343176 EPG S2 FM (USA edition)
The standard equipment includes:
2322580 Declaration of Conformity
2317573 Operating manual, in German
See Languages
[86]
Operating manual in local language
5.3 TECHNICAL DATA
Dimensions:
Height 136mm; 5.35inch
Width 270mm; 10.63inch
Depth (without operating elements) 300mm; 11.81inch
Weight 5.5kg; 12.13lb
Electrical:
Mains (AC) 90VAC – 250VAC
Frequency 47Hz – 63Hz
AC input power maximum 60 W
Output voltage to guns 2x maximum 22Vpp
Output current 2x maximum 0.9A
High voltage 2x 10 – 100kV
(adjustable in 1kV steps)
Corona current limitation 5µA – 120µA
(adjustable in 1µA steps)
Tribo current measurement 0µA – 20µA (resolution 0.1µA)
Minimum Tribo current limitation 0µA – 5µA (adjustable in 0.1µA steps)
Maximum Tribo current limitation higher than 12µA
(EX: switching off of the unit)
CAN bus IN/OUT Signal optically separated
Protocol: CANopen
Release 24VDC

Operating manual Universal Control Unit for Powder Spray Guns EPG S2, EPG S2 FM
5 Description
18 Order number 2317574 | Edition 10/2022
Electrical:
Protection class IP64
Ex identification for EPG S2 II 3(2)D
Ex identification for EPG S2 FM Class II, Division E, F and G
Pneumatic:
Input air pressure 0.6 – 0.8MPa; 6 – 8bar; 87 – 116psi
Air flow maximum 30m³/h
6 x air quantity regulator with
ACTUAL value measurement
0.00 – 6.00m³/h
(adjustable in 0.025m³/h steps)
Required compressed air quality as per
ISO8573.1
6.5.2 (5µm/+7°C; +44.6°F/0.1mg/m³)
Connection hose diameter 8mm; 0.315inch
Ambient conditions:
Operating temperature range for EPG S2 5°C to 40°C; 41°F to 104°F
Operating temperature range for EPG S2
FM
5°C to 45°C; 41°F to 113°F
WARNING
Exhaust air containing oil!
Risk of poisoning if inhaled.
Insufficient paint application quality.
4The compressed air must meet the following quality requirements: (Quality
Standard 6.5.2 according to ISO 8573.1, 2010) 6.5.2 = particle density ≤ 5 mg/m³;
pressure dew point ≤ +7 °C; oil content ≤ 0.1mg/m³
NOTICE
Compressed air quality, accessories
Danger of damage to the device.
4Operate the control unit only with the prescribed compressed air quality.
4Only use the control unit with original WAGNER accessories.
4Non-observance of these conditions results in the warranty expiring.
Ambient conditions:
When using low-melting powder varieties, an ambient temperature below 30°C (86°F) may
be necessary.
Volume measures:
for volumes specified in Nm3 (standard cubic meters). One cubic meter of gas at 0°C and
1.013bar is referred to as a normal cubic meter.

Operating manual Universal Control Unit for Powder Spray Guns EPG S2, EPG S2 FM
5 Description
Order number 2317574 | Edition 10/2022 19
5.4 OPERATING ELEMENTS
5.4.1 Display Elements on Front Side
P_01487
A B
S2
EPG
36 5 42164 5
1 LED display: Operating voltage
– The LED lights up green when the operating voltage is activated
2 LED display: CAN data communication
– The LED lights up green during data communication with the master
3 LED display: Release
– The LED lights up green when enabling has taken place
4 LED display: Air
– The LED lights up green when the air module is activated
5 LED display: High voltage
– The LED lights up green when the high voltage is activated
6 LED display: Warning/Malfunction
– The LED flashes in the event of a warning and lights up red in the event of a malfunction
Displays 4 - 6 exist for both gun A and gun B.

Operating manual Universal Control Unit for Powder Spray Guns EPG S2, EPG S2 FM
5 Description
20 Order number 2317574 | Edition 10/2022
5.4.2 Connections on the Rear Side of the EPG S2
Year of build:
Baujahr:
B
Für den Betrieb in der Zone 22
müssen alle Anschlüsse mit Stecker
oder Schutzkappe versehen sein.
Prim. Fuse
Sicherung
1.0 AT
(slow blow)
Spraygun
Sprühpistole
IN CAN Bus OUT
Data and Interlock
Daten und Verriegelung
Ausgang zur Pistole
Output to gun
I max. 0,9 A
U max. 22 Vpp
Dosage air
Dosierluft
Feeding air
Förderluft
Atomizing air
Zerstäuberluft
Mains power IN / OUT
Netz EIn / Ausgang
6.....8 bar
87..116 psi
Clean and
dry air
Saubere und
trockene Luft
6.5.2 (ISO 8573.1)
Do NOT disconnect under voltage!
NICHT unter Spannung trennen!
Air input
Lufteingang
Dosage air
Dosierluft
Feeding air
Förderluft
Atomizing air
Zerstäuberluft
A
A AB B
Type / Typ:
Serial No.:
Serie Nr.:
Voltage:
Spannung:
Line Power:
Eingangsleistung:
Prot. Class:
Schutzklasse:
EPG S2
90-250 VAC 47-63 Hz
max. 60 W
IP 64
For operation all ports must be fitted
with a plug or the protection cap.
12
8 17 16 15 11 10 9 8
73 4
P_01488
14
5 6
1213
CH 9450 Altstätten
Made in Switzerland
II 3(2)D IP64 80ºC
Tested / Geprüft EN50050-2, EN50177
BS EN50050-2, BS EN50177
PTB 12 ATEX 5001 / CSAE 21 UKEX 5714
Wagner International AG
0102
0518
Service
Port
CAN
Address
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
1 2 3 4
1 Primary fuse
– 1 ampere, slow-acting
2 Grounding connection
– To connect the signal ground
3 Compressed air inlet
– The LED lights up green when enabling has taken place
– Pressure range: 0.6 – 0.8MPa; 6 – 8bar; 87 – 116psi
– Air volume: 2x maximal 15m³/h
– Connection hose diameter 8mm; 0.315inch
4 Input: CAN bus connector plug
– CANopen communication signal
– Release signal
5 Output: CAN bus bushing
– CANopen communication signal
– Release signal
6 Gun connection B
– To connect a Corona or Tribo gun
7 Gun connection A
– To connect a Corona or Tribo gun
8 Fastenings
– For screwing to the rack
9 Cover of the service connection
– Once the cover has been removed, the DIP switches and rotary switches for the CAN bus
address, CAN bus baud rate and the switch for emergency mode can be set.
Other manuals for EPG S2
1
This manual suits for next models
1
Table of contents
Other WAGNER Controllers manuals
Popular Controllers manuals by other brands

Ldsolar
Ldsolar TD2210 user manual

Denon
Denon DN-HC4500 - DJ Mixer USB Controller quick start guide

Lionel
Lionel RAILROAD quick start guide

Mitsubishi Electric
Mitsubishi Electric MELSEC-A Series user manual

ProMinent
ProMinent DULCOMETER D1Cb Instructions for assembly and use

Whelen Engineering Company
Whelen Engineering Company Wireless Traffic Advisor Installation guides