Technical Manual 121410-0
FluidWorker Mobility Kit
SAFETY
Risk of personal injury
• Never use on sloped ground.
• Never use on uneven ground.
• Alwaysacvatebrakeswhenstaonary.
Risk of contaminaon
• When notinoperaon,neverleavetheFluidworkermorethan24hwithoutthourough
drainingandcleaning.Useawetvacuumfordrainingandsystemcleanerfordisinfecon.Ifliquid
remainsintheFluidWorker,thereisariskthatbacteriawillgrowtohighlevels.Thiscan
contaminatewhentheproductisputintoservice.
MOVING THE FLUIDWORKER BETWEEN TANKS
Note: FluidWorkerreducesbacteriainthemachinetankitisinstalledon.Beforemovingtothenext
machine,therootcauseofbacterialproblemsmustberesolvedandtheuidmustbeadjustedto
theconcentraonandpHvaluerecommendedbytheprocessuidsupplier.
1. DraintheFluidWorker:WiththeFluidWorkerinoperaon,demountthetankbracketandcarefully
lithepipesabovewaterlevel.Waitunlnomoreuidejects.
2. Placethepipesandtankbracketintothecontainer(4)onthebackoftheFluidWorker.
3. TurntheFluidWorkero,swiththemainswitchoandunplugthepowerplug.
4. Forthoroughdraining(recommended),opentheprimingtankandsuckdryusingawetvacuum.
5. Movetothenewtank.
6. Carefullymountinletandoutletpipes,makingsureinletismidwaybetweensurfaceand
boomandoutletisdirectedtocreateopmalcirculaoninthetank.
7. Filluptheprimingtankwithwaterorprocessuid.Closethelid.TurntheFluidWorkeron.
CONTENT
1:Wheelbracket 2x
2:ScrewMRTFZBM6x20 4x
3:Containerholder 1x
4:Container30L 1x
2
1
3
4