WAREMA BAline KNXMCM User manual

1
warema_2012123_alhb_en_v5•2022-03-01 We reserve the right to make technical modifications
Safety instructions
ARNINGW
The electrical installation (assembly)/
dismantling must be performed by a cer-
tified electrician in accordance with the
electrical installation regulations published
by the Association of German Electrical
Engineers (VDE 0100) or the standards
and regulations of the country in which the
device is being installed. The electrician
must observe the installation instructions
included with the electrical devices.
ARNINGW
If it can be assumed that safe operation is
not possible, the device must not be com-
missioned or must be decommissioned if
it is already in service. This assumption is
justified if
The housing or the supply lines show
signs of damage
The device is no longer working.
ARNINGW
For the safe functioning of the entire sys-
tem it is necessary that the drives, motor
control units and power supplies are
accurately coordinated with one another.
Therefore, please contact our project man-
agement before planning.
ARNINGW
The control software loaded at the factory
cannot be used for operation in a system.
The control software loaded at the factory
must be replaced by system-specific con-
trol software.
General information
Fig. 1 BAlineKNXMCM
The BAline product line is a system consisting of individual
modules for room and building automation (such as sun
shading systems, lighting, windows, HVAC, etc.). Each
basic module (e.g. BAline KNXMCM) for bus coupling can
be connected to up to 8IO modules. The basic module
can be combined with one or more IO modules as need-
ed. With this system, rooms can be automated in a wide
variety of ways.
The BAlineKNXMCM controller is a basic module for
room and building automation to which various extension
modules can be connected. The BAlineKNXMCM device
is equipped with a KNX TP1 interface. The device applica-
tion is loaded and monitored via a USB interface.
The extension modules can be connected using the
BAline jumper, A maximum of 8 IO modules can be con-
nected to a BAlineKNXMCM basic module.
Intended use
The BAlineKNXMCM is a basic module for room and
building automation. Any use other than the purpose
described in these instructions requires manufacturer
approval.
BAline KNXMCM
Installation instructions
Valid from
1. March 2022
Keep for future use.

warema_2012123_alhb_en_v5•2022-03-01We reserve the right to make technical modifications
2
Installation
The module is designed for distributor installation (DIN
rail-mounted housing (REG)).
When installing the device in a distributor, clip it onto a
symmetrical DIN rail (TH35-15). For easier connection
of the device, the terminal covers can be removed (Fig.
2).
Remove the terminal covers:
Insert a suitable screwdriver
into the notch.
Fig. 2 Detaching the terminal covers
Connection
An on-site overload current disconnecting and isolating
switch must be provided to cut off power to the entire
system.
The module is electrically connected according to the
wiring diagram on the reverse (seeFig. 5).
For loading and monitoring the device apllication
a Mini USB cable is required for the USB inter-
face.
Connection to BAline extension modules
Connect the BAlineKNXMCM to an extension module
(Fig. 3). The connection of the BAlineKNXMCM is locat-
ed on the right side; the device is always mounted at the
beginning of the module chain (at the far left).
Fig. 3 BAlineKNXMCM module
Initial operation
Once installation is complete and the operating voltage
is supplied, the device can be placed into service. The
control software loaded at the factory must be replaced by
system-specific control software.
To create, test and load the system-specific control
software, use the BAlineStudio PC software. After the
system-specific control software is loaded, the extension
modules and the connected devices can be placed in
service.
A software manual (art. no.2014978) is available for the
BAlineStudio PC software. Contact your system integrator
to request the manual.
Take suitable precautions in order to avoid
damage through electrostatic discharges!
Maintenance
There are no parts inside the device that require mainte-
nance.
Cleaning
Clean the housing with a soft, dry cloth. Do not use deter-
gents, cleaning agents, solvents, abrasive substances or
steam cleaners!
Liability
Failure to comply with the product information contained in
these instructions and any use of the device other than its
intended use and purpose may result in the manufacturer
refusing to honour warranty claims for product damage. In
this case, liability for consequential damage to persons or
property will also be excluded.
Obligations for the disposal of electrical
devices
A marking with this symbol indicates the following
obligations under the scope of legal regulations:
The owner of this electrical device must dispose of it
separately from unsorted municipal waste for further
recycling.
Used batteries and accumulators that are not enclosed
in the old device, as well as lamps/bulbs that can be
removed from the old device without breaking, must be
disposed of separately.
Distributors of electrical devices and disposal compa-
nies are obliged to take back the equipment free of
charge
.
The owner must take it upon themselves to delete any
personal data contained in the electrical device prior to
disposal.

3
warema_2012123_alhb_en_v5•2022-03-01 We reserve the right to make technical modifications
Technical data
BAlineKNXMCM Min. Typ. Max. Unit
24V DC supply (SELV)
Operating voltage 20 24 28 VDC
KNXMCM 35 mA
KNXMCM +
MIO extension modules 2 A
Interface KNX TP1
Voltage 29 VDC
Current consumption 3.5 13 mA
Housing
DIN rail-mounted housing
(REG) 3 MW
Dimensions See Fig. 4
Degree of protection IP30
Safety class III
Ambient conditions
Operating temperature 0 50 °C
Storage temperature -25 70 °C
Rel. humidity
(not condensing) 10 40 85 %Frel
Degree of soiling 2
Connection
24VDC supply Screw terminals
RS485 bus, supply of the
following modules
Jumper
(24VDC, max. 1.5A)
KNX bus system Spring terminals
Connection terminals
24VDC supply max. 2.5mm2
KNX bus system 0.6...0.8mmø
Miscellaneous
Conformity
Available at
www.warema.com
This device complies with the EMC directives for use in residen-
tial and commercial areas.
Article numbers
BAlineKNXMCM 2007 460
Jumper 317 943
Accessories
Mini USB cable 634 307
WAREMA Renkhoff SE
Hans-Wilhelm-Renkhoff-Strasse 2
97828 Marktheidenfeld
Germany
60 mm
95 mm
90 mm
54 mm
3 MW
60 mm
Fig. 4 Dimensions

warema_2012123_alhb_en_v5•2022-03-01We reserve the right to make technical modifications
4
Output to next component
Input from previous components
YCYM 2x2x0.8 mm ø
9876
24 V DC/2,5 A
Power supply unit
JY(St)Y 2x2x0.8 mm ø
0 V
+ 24 V
0 V
+ 24 V
X1 X2
+24V +24V 0V 0V
Power
+ -
BAline
KNXMCM
KNX
KNX TP1
S1 D300
Status
Power
Attention! The supply voltage of
24 V DC must be SELV voltage
in accordance with VDE 0805
or EN 60950.
Fig. 5 Connecting the BAlineKNXMCM
Other WAREMA Control System manuals
Popular Control System manuals by other brands

Hitachi
Hitachi YUTAKI ATW-YMM-01 Installation and operation manual

Polar Electro
Polar Electro Connect instructions

Norac
Norac UC4.5 installation manual

iO HVAC Controls
iO HVAC Controls ZP3-HCMS Installation and operation instructions

EUCHNER
EUCHNER MSC Operating Instructions, Installation and use

Ltech