Home Maintenance
There is no power to the remote display…………………….
If there is a loss of power to the valve controller, it will continue to work normally on battery
power for several months. Power to the remote display will be cut off to conserve the battery
power. Connections to the intruder alarm and/or building management system will continue
as normal. See page 2 for instructions on how to operate the system using the valve driver.
As soon as mains power is restored the system will operate fully as normal and will have
remembered previous guard levels.
The valve doesn’t open or close…………………….
If all controls are functioning as normal but the valve is failing to close, please see Routine
Maintenance below as the valve assembly may be blocked up.
How to manually bypass the valve to allow water flow…………………….
WARNING The manual bypass must only be used
in an emergency to restore the water supply when
the controller is damaged or there has been a long
term loss of mains power.
Rotate the whole coil head as shown. THIS WILL
DEACTIVATE WATER LEAK PROTECTION AND
MAY INVALIDATE YOUR HOME INSURANCE.
Please contact the technical support team if any further assistance is required.
General Maintenance
Automatic Testing –The valve driver is programmed to automatically close and open the
valve every 24 hours whilst in high guard. This tests both the valve assembly and controls.
Routine Maintenance –This system requires minimal maintenance and will only require
the following:
•In hard water areas it is recommended that the valve assembly is dismantled and
cleaned with limescale remover every 12 months as build up can cause the unit to
fail
•After continued power loss the valve driver back up battery may need replacing. It
is recommended that a suitably qualified engineer changes the battery (3 volt
lithium, size code CR123A) after firstly turning off mains power to the unit
Water Leak Detection Equipment
Waterguard Home
Operating & Setup
The residential solution to water leak prevention
© 2017 Waterguard Services Limited, All Rights Reserved
Waterguard Services Limited. Registered address: 22 Oakwell Business Centre, Oakwell View, Barnsley,
South Yorkshire, S71 1HX. Tel: 01226 244200. Email: enquiries@waterguard.co.uk.
VALVE ON
BYPASS
VALVE
NORMAL
Sustainable
Products Under
the ECA Scheme
System Profile
The Waterguard Home is a language free water leak prevention system which continuously
monitors the water flow from the incoming supply. Features include:
•Automatically shuts off the water supply when a predetermined maximum
continuous flow time (guard level) has been exceeded
•Has two levels of guard, low guard (occupied) and high guard (unoccupied)
•Has an integrated back-up battery for continuous power
System Controls
The remote display…..
The valve driver…..
Understanding the Controls
The remote display…..
Current Display
Meaning
Off
The valve driver has closed the valve. Please see, the Operating the
Controls section
3 digit number, e.g.
010
The system is set to Low Guard, the last time value displayed before the
screen times out is the active time
2 digit number with a
decimal point e.g. 0.1
The system is set to High Guard, the last time value displayed before the
screen times out is the active time
3 dashes running
across the display
The remote display is communicating with the valve driver
None of the above
The remote display may be damaged or in an error state. Please call
technical on 01226 397895
The valve driver…..
LED Indicator
Buzzer
Meaning
Solid red
Silent
Unit operating normally
Off, followed by brief
flashes
Silent
Device running on battery backup. Please see, the
Home Maintenance section
Equal intermittent
flashes
Equal intermittent
beeps
The valve driver has closed the valve. Please see, the
Operating the Controls section
Solid red followed by
brief flashes
Silent
The valve driver has closed the valve as the battery
backup requires replacing. Please see, the General
Maintenance section. In order to reinstate the water
supply, bypass the valve manually. Please see, the
Home Maintenance section
Operating the Controls
Control & setup of the remote display…..
Action
Dial/Button
Setup
Awaken the
display
Single button
press
No setup required
Switch between
guard levels
Single button
press
Must be done each time the occupant enters and
exits the property. If the system is linked to an intruder
alarm, it will automatically switch between guard levels
Input low guard
level –
Waterguard
recommend max
20 minutes.
Rotate dial both
ways until the
desired time is
found
Low guard level is intended for when people are in the
property and water is being used. In low guard the
guard time can be set from 0 to 30 minutes (displayed
as 000 to 030). The last time value displayed before
the screen times out is the active time for this guard
level.
Input high guard
level –
Waterguard
Recommend
max 2 minutes.
Rotate dial both
ways until the
desired time is
found
High guard is a higher protection level, used when the
property is unoccupied. In high guard the guard time
can be set from 0 to 3 minutes (displayed as 0.0 to
3.0, each decimal point equates to 6 secs). The last
time value displayed before the screen times out is the
active time for this guard level.
To close the valve using the remote display, whilst in high guard set the time to 0.0.
Controlling the system from the valve driver…..
Button Press
Command
Single short
press when valve
is closed
This will open the valve and set the unit to high guard, confirmed by a
singular flash and beep
Single short
press when valve
is open
If in high guard - this will switch to low guard level, confirmed by 2 flashes
and beeps
If in low guard - this closes the valve, confirmed by 3 flashes and beeps
Remote Display Button
•Awakens the display –
unit will automatically
switch off after 10
seconds
•Switches between guard
levels
Remote Display
Dial - Adjusts flow
time allowances for
each guard level
Valve Driver
Button - Operates
basic system
functions
Valve Driver Red
LED - Indicates
current status of
system

Other WATERGUARD Security Sensor manuals

WATERGUARD Solo User manual

WATERGUARD

WATERGUARD Solo User manual

WATERGUARD 7 V17X Setup guide

WATERGUARD

WATERGUARD 7 V17X Setup guide

WATERGUARD WRAS V21 User manual

WATERGUARD

WATERGUARD WRAS V21 User manual

WATERGUARD 7 Series Setup guide

WATERGUARD

WATERGUARD 7 Series Setup guide

WATERGUARD Solo User manual

WATERGUARD

WATERGUARD Solo User manual

WATERGUARD Solo User manual

WATERGUARD

WATERGUARD Solo User manual

WATERGUARD Puddle User manual

WATERGUARD

WATERGUARD Puddle User manual

Popular Security Sensor manuals by other brands

Vision ZB5311IN-5 Installation & operation manual

Vision

Vision ZB5311IN-5 Installation & operation manual

Tool Shed TSDSF manual

Tool Shed

Tool Shed TSDSF manual

EMX Industries VMD202 instruction manual

EMX Industries

EMX Industries VMD202 instruction manual

GMI Shipsurveyor User handbook

GMI

GMI Shipsurveyor User handbook

PCB Piezotronics M108A04 Installation and operating manual

PCB Piezotronics

PCB Piezotronics M108A04 Installation and operating manual

Lince DTP 20 quick start guide

Lince

Lince DTP 20 quick start guide

Datalogic SG4-H14-015-OO-X-B instruction manual

Datalogic

Datalogic SG4-H14-015-OO-X-B instruction manual

Jung 3360 operating instructions

Jung

Jung 3360 operating instructions

AccuBANKER LED61 user guide

AccuBANKER

AccuBANKER LED61 user guide

Apollo REACH RW1000-460APO quick start guide

Apollo

Apollo REACH RW1000-460APO quick start guide

Visonic TOWER 20 AM - INSTALLER GUIDE installation instructions

Visonic

Visonic TOWER 20 AM - INSTALLER GUIDE installation instructions

EpiSensor ZDI-20 user guide

EpiSensor

EpiSensor ZDI-20 user guide

Elkron IRA31WL quick start guide

Elkron

Elkron IRA31WL quick start guide

SATA 62702 user manual

SATA

SATA 62702 user manual

Z-Wave Aeotec 7 Pro manual

Z-Wave

Z-Wave Aeotec 7 Pro manual

Heico STE Radiation Pager user manual

Heico

Heico STE Radiation Pager user manual

Vertiqual Engineering SRL V41 instruction manual

Vertiqual Engineering SRL

Vertiqual Engineering SRL V41 instruction manual

Greystone Energy Systems WD-100 Series installation instructions

Greystone Energy Systems

Greystone Energy Systems WD-100 Series installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.