WDT DUFTDOS-0-Compact User manual

Item no.: 17630 Language: EN
Operating instructions
Fragrances dosing for steam rooms
Type DUFTDOS-0-Compact

Fragrances dosing, type DUFTDOS-0-Compact
Index: 01 Change date: 01/12/2017 Operating instructions no.: BA DW 017-01 Duftdos-0-Compact EN 17630.docx Page 2 of 21
Table of contents
1Information regarding these instructions / general information .............................................................. 3
Scope of validity..........................................................................................................................................3
Target group .............................................................................................................................................. 3
Symbols used..............................................................................................................................................3
Warranty ...................................................................................................................................................4
Further information .................................................................................................................................... 4
2Safety ...................................................................................................................................................... 5
Appropriate use .........................................................................................................................................5
Safety instructions.......................................................................................................................................5
2.2.1 Handling of chemicals, risks to persons and the environment .....................................................................5
2.2.2 Protective measures and behavioural rules .................................................................................................5
3Product description - delivery scope........................................................................................................ 6
Delivery scope / accessories....................................................................................................................... 6
Product description ....................................................................................................................................6
3.2.1 Dosing unit .................................................................................................................................................7
3.2.2 Dosing valve (option).................................................................................................................................7
3.2.3 Console (option).........................................................................................................................................7
Identification of the device / name plate .....................................................................................................7
Technical data............................................................................................................................................. 8
Transport / storage....................................................................................................................................8
4Installation ............................................................................................................................................... 9
Selecting the place of installation.................................................................................................................9
Installation information (installation suggestion)..........................................................................................9
Mechanical installation ..............................................................................................................................10
Hydraulic installation.................................................................................................................................10
Electrical installation..................................................................................................................................10
5Commissioning ...................................................................................................................................... 11
Commissioning - comments ......................................................................................................................11
Commissioning works ..............................................................................................................................11
5.2.1 Insert the roller carrier of the hose pump.................................................................................................11
5.2.2 Prepare the fragrance concentrate ...........................................................................................................12
5.2.3 Connect the device and aerate the dosing pipe.........................................................................................12
6Operation / handling............................................................................................................................. 13
General.....................................................................................................................................................13
Control.....................................................................................................................................................13
Control - software ....................................................................................................................................13
Top up consumables.................................................................................................................................13
7Maintenance, service, faults ................................................................................................................... 14
Device maintenance..................................................................................................................................14
7.1.1 Check / replace hose set ..........................................................................................................................14
7.1.2 Check the dosing valve .............................................................................................................................15
7.1.3 Check function of the pump .....................................................................................................................16
7.1.4 Fault removal............................................................................................................................................16
8Shutting down - Storage - Disposal ........................................................................................................ 17
General.....................................................................................................................................................17
Shutting down ..........................................................................................................................................17
9Documents............................................................................................................................................ 18
Declaration of conformity.........................................................................................................................18
Terminal plan............................................................................................................................................19
Commissioning protocol / instruction ......................................................................................................19
Operating data sheet ................................................................................................................................20
Maintenance protocol ...............................................................................................................................20
Spare parts list, wearing parts list, consumables list ..................................................................................21
10 Appendices............................................................................................................................................ 21

Fragrances dosing, type DUFTDOS-0-Compact
Index: 01 Change date: 01/12/2017 Operating instructions no.: BA DW 017-01 Duftdos-0-Compact EN 17630.docx Page 3 of 21
Imprint
All rights reserved
© Copyright by WDT –Werner Dosiertechnik GmbH & Co KG
Version: see footer
Publications of any kind and translation into other languages, also of excerpts, is only permitted with the
explicit approval of WDT - Werner Dosiertechnik GmbH & Co. KG.
These operating instructions are based on the German original provided by the WDT Company.
Responsible for the content:
WDT - Werner Dosiertechnik GmbH & Co. KG
Hettlinger Str. 17
D-86637 Wertingen-Geratshofen
Phone: +49 (0) 82 72 / 9 86 97 –0
Fax: +49 (0) 82 72 / 9 86 97 –19
E-mail: info@werner-dosiertechnik.de
1Information regarding these instructions / general information
Scope of validity
These instructions describe the function, installation, commissioning and operation of the device with appro-
priate accessories.
The operating instructions must be carefully read before using or maintaining the device and have to be stored
in immediate proximity of the device!
Target group
Only our authorised partners and persons who were instructed regarding the device functions and have read
and understood the operating instructions may work on the system.
Electrotechnical connection work may only be performed by appropriately trained specialist staff!
Symbols used
The following types of safety instructions and general instructions are used in this document:
DANGER !
"DANGER" indicates a safety instruction that must be adhered to at the risk of death
or severe injury!
CAUTION !
"CAUTION" indicates a safety instruction that must be adhered to at the risk of light
to medium injuries!
ATTENTION !
"ATTENTION" indicates a safety instruction that must be adhered to at the risk of
damage to goods breakdowns!
HIGHLY FLAMMABLE !
"HIGHLY FLAMMABLE" identifies substances with a low flash point under 21°C.
Hint !
A "Hint" characterises information that may help to improve the operation.

Fragrances dosing, type DUFTDOS-0-Compact
Index: 01 Change date: 01/12/2017 Operating instructions no.: BA DW 017-01 Duftdos-0-Compact EN 17630.docx Page 4 of 21
Warranty
All devices and systems of the WDT Company are produced using the latest production methods and com-
prehensive quality control. Please send your warranty claims according to the general warranty conditions
(see below) to WDT should there nevertheless be a reason for complaint.
General warranty conditions
WDT provides a warranty for 2 years from the date of commissioning, a maximum period of 27 months
after delivery, assuming correct installation and commissioning with completed and signed commissioning
protocol.
Wearing parts such as seals, hoses, membranes, dosing screw conveyors, electrodes, roller carriers and other
parts that are subject to mechanical or chemical wear are excluded. We provide a warranty for half a year
on those parts.
Our ERP program requires an invoice for each delivery (also for warranty services). Customers will receive a
credit note after returning the faulty part and its inspection as required. Please return goods within 14 days.
Costs for consequential damage and costs resulting from handling warranty claims are excluded.
Warranty claims are not valid when the damage was caused by frost, water, over-voltage or inappropriate
handling.
Hint !
Please send a completed commissioning protocol together with the defective part to
WDT to maintain your warranty claims. We reserve the right to settle the warranty
claim when no completed commissioning protocol is available.
ATTENTION !
Modification of the device is not permitted. In case of a modification of the device, the
warranty and the product liability do not apply anymore!
Further information
Additional information regarding specific topics such as description of the operating parameters as well as
further support is available from your specialist dealer.

Fragrances dosing, type DUFTDOS-0-Compact
Index: 01 Change date: 01/12/2017 Operating instructions no.: BA DW 017-01 Duftdos-0-Compact EN 17630.docx Page 5 of 21
2Safety
Appropriate use
The fragrance dosing device type DUFTDOS-0-Compact may only be used for the purposes specified in Sec-
tion 3.2 “Product description”! The locally applicable regulations regarding accident prevention, worker safety
and drinking water protection must be adhered to.
Safety instructions
The operating instructions must be carefully read and considered before installation and use!
Work on the system and changes to the settings may only be performed by trained and instructed persons!
The regulations for worker safety and accident prevention as well as for wearing protective clothing must be
adhered to.
Take note of the warning information on the device!
2.2.1 Handling of chemicals, risks to persons and the environment
Important information on the handling of chemicals and fragrances is provided in the
safety data sheets of the fragrance manufacturers!
With the fragrance dosing a fragrance concentrate is mixed with the fragrance concentrate and is conveyed
into the steam room. The fragrance concentration in the steam is so low that it poses no risk to people.
DANGER ! IRRITATION !
Fragrances concentrates may lead to irritation and allergic reactions.
HIGHLY FLAMMABLE !
Fragrances concentrates may be highly flammable. This may cause injuries to persons
or risks to the environment. Work carefully!
CAUTION !
Fragrance concentrates can be harmful for the health!
Wear protective gloves and protective glasses.
In emergencies relating to the handling of chemicals, you can contact a Poison Emergency Call Cen-
tre!
Emergency call number:
Poison Emergency Call Munich (or any other poison centre)
Telephone: +49 89 19240
2.2.2 Protective measures and behavioural rules
ATTENTION !
Modifications at the device are forbidden. Warranty and product liability claims be-
come void when this requirement is not fulfilled.
Check the dosing hose of the pump
and replace it as required when top-
ping up the fragrance
(see operating instructions).

Fragrances dosing, type DUFTDOS-0-Compact
Index: 01 Change date: 01/12/2017 Operating instructions no.: BA DW 017-01 Duftdos-0-Compact EN 17630.docx Page 6 of 21
3Product description - delivery scope
Delivery scope / accessories
The device mainly consist of the following components:
Hose dosing pump SA, approx. 3 l/h
Connection cable 4 x 1mm2- 3m
Roller carrier SA yellow
Dosing hose 3.2 x 1.6 Viton with hose holder on 4 x 1 mm
Suction hose PE 4 x 1 - 1.5 m
The following options are available as accessories:
Dosing set
Console for round jar with wide neck, 1.5 litres
Console for canister, 10 litres
Order numbers see Section 9.6 “Spare parts list, wearing parts list, consumables list“.
Product description
The fragrance dosing type DUFTDOS-0-Compact refers to a dosing system for the dosed introduction of
fragrance concentrate in the steam pipe of steam rooms.
Function
The fragrance concentrate is dosed through the hose pump passing the dosing pipe into the steam pipe. The
pump must be connected in such a way that it can only dose during the steam production. The dosing power
depends only on the diameter of the dosing hose. The dosing pipe is made of transparent PTFE, so that during
the deaeration the air bubble in the pipe can be observed.
The optional dosing valve is assembled into the dosing pipe to connection the dosing power.
ATTENTION !
The device must be connected in such a way that dosing is only done during the steam
production of the steam generator.
Overview of the fragrance dosing type: DUFTDOS-0-Compact
Figure 1, DUFTDOS-0-Compact
Legend
1 Housing
2 Housing cover
3 Hose dosing pump
4 Transparent protection cover
5 Pressure connection for dosing pipe to
the steam pipe
6 Console for round jar with wide neck
7 Warning sign
8 Suction connection for hose pipe to the
fragrance concentrate container
5
6
7
2
3
1
4
8

Fragrances dosing, type DUFTDOS-0-Compact
Index: 01 Change date: 01/12/2017 Operating instructions no.: BA DW 017-01 Duftdos-0-Compact EN 17630.docx Page 7 of 21
3.2.1 Dosing unit
For the fragrance dosing a hose pump is used, conveying even the smallest
dosing volumes securely, even when there are air bubbles in the suction
pipe. Rotating rollers press the dosing hose against the wall, squeezing out
the liquid in front of the rollers while sucking in new liquid at the same time.
Hose pumps are extremely reliable and particularly easy to operate.
Fragrance concentrates can be extremely corrosive. The dosing hose used
resists most of the commercially available concentrates.
ATTENTION !
The composition of the fragrance varies. This may reduce the service life of the hose.
You should therefore regularly check the fragrance pump according to the mainte-
nance plan or whenever fragrance is topped up.
3.2.2 Dosing valve (option)
The valve is a combined spring loaded non-return valve and dosing valve.
In case of a defect of the pump or the dosing pipe (broken hose, mainte-
nance works) the dosing valve avoids the penetration of steam from the
steam pipe into the dosing pipe.
In the error free operation no dosing valve is required since the pressure of
the pump is higher than the pressure in the steam pipe.
3.2.3 Console (option)
The device is supplied standard for wall Installation. The fragrance container is put on the floor.
The optional console is foreseen for an Installation at a higher level, so that the floor remains free. The fra-
grance container is put on the console. The console is available in two sizes.
Identification of the device / name plate
Enter the data on the name plate of your device here.
Array 1: Enter the serial number
Array 2: Enter the production date
Figure 2, Hose pump function
Figure 4, Name plate
Figure 3, Dosing valve

Fragrances dosing, type DUFTDOS-0-Compact
Index: 01 Change date: 01/12/2017 Operating instructions no.: BA DW 017-01 Duftdos-0-Compact EN 17630.docx Page 8 of 21
Technical data
DUFTDOS-0-Compact
Dimensions and weights:
External dimensions
approx. 0.14 x 0.07 x 0.8m (HxWxD)
Space requirements
approx. 0.50 x 0.30 x 0.30m (HxWxD)
Space requirements incl. operation and
maintenance
approx. 2.00 x 0.60 x 0.90m (HxWxD)
Weight
approx. 0.6kg
Connection data
Connection dosing
Dosing hose Ø 6/4mm
Electrical connection
230 VAC/50Hz, 6W
Protection type
IP65
Operating data:
Medium temperature
5-35°C
Environmental temperature in utility
room
5-35°C
Humidity in utility room
max. 70%
Suction height
max. 2m
Ventilation and extraction
Recommended for the utility room
Operating pressure
max. 1.5 barg
Transport power in the continuous mode
max. 3l/h
Transport / storage
The device must be checked for possible transport damage immediately after receipt.
ATTENTION !
The device can get damaged by frost or high temperatures. Prevent exposure to frost
during transport and storage! Do not store the device next to objects with high heat
radiation or directly exposed to sunlight. The device may only be transported and
stored in its original packaging. Careful handling must be ensured.
The roller carrier of the dosing pump is not installed during transport and storage. This prevents deformation
of the hose.
Storage of fragrances / chemicals
DANGER !
The safety data sheets of the fragrance manufacturers have to be considered with re-
gard to storage!
The following points must be considered, among others:
Fragrance concentrates may only be stored in appropriately marked, original plastic containers.
The fragrance concentrates must be stored in a separate storage room.
The environmental temperature may not exceed 20°C.
See at this regard also Section 2.2.1 “Handling of chemicals, risks to persons and the environment“.
CAUTION !
Follow locally valid rules for the handling of chemicals!

Fragrances dosing, type DUFTDOS-0-Compact
Index: 01 Change date: 01/12/2017 Operating instructions no.: BA DW 017-01 Duftdos-0-Compact EN 17630.docx Page 9 of 21
4Installation
The work described here may only be performed by appropriately trained specialist staff or by a specialist
company.
Selecting the place of installation
The place of installation must have the following characteristics:
1. The place of installation must be protected against frost.
2. The device must be protected against direct sunlight.
3. An electrical mains connection must be available.
4. Good air supply and extraction are recommended for the installation room.
Installation information (installation suggestion)
The device is assembled in the technical room at a wall. The dosing pipe to the steam pipe must be as short
as possible.
Consider the space required for operation and maintenance of the device, see Section 3.4 Technical data.
Warning and information signs according to the locally valid accident prevention regulations are to be
provided at the intended positions.
Mounting diagram
Figure 5, Installation suggestion
Steam cabin
Steam pipe
Dosing pipe
Dosing valve
Lock the plug
socket DUFTDOS
with steam gener-
ator
Steam generator

Fragrances dosing, type DUFTDOS-0-Compact
Index: 01 Change date: 01/12/2017 Operating instructions no.: BA DW 017-01 Duftdos-0-Compact EN 17630.docx Page 10 of 21
Mechanical installation
Installing the dosing device
The dosing device is supplied ready to use on a roller carrier.
The device is assembled in the technical room approximately 1 m above the floor. In case of Installation with
console, the device can be assembled at any height. The container with the fragrances concentrate is put
underneath the device.
1. When choosing the Installation place, ensure a good accessibility.
2. Fix the device with 4 screws onto the wall or the console.
Hydraulic installation
ATTENTION !
Do not bend the dosing pipe.
Install the dosing pipe in such a way that the fragrance concentrate cannot flow through
the steam pipe into the steam generator.
1. If necessary, screw the dosing valve (option) at the dosing point in the steam pipe.
2. In case of a bigger distance between the installation place and the dosing valve, install a transparent protec-
tion pipe for the dosing pipe, if necessary.
3. Connect the dosing pipe at the right connection of the hose pump.
4. Connect the other end of the dosing pipe onto the steam pipe (dosing valve).
5. Connect the suction pipe at the left connection of the hose pump.
Electrical installation
The dosing pump is supplied with connection cable without plug. The pump starts running as soon as power
is supplied. Therefore the pump must be connected to an external control. See Section 9.2, “Terminal plan“.
Do not open the casing.
DANGER DUE TO HIGH VOLTAGE !
The electrical installation may only be performed by appropriately trained specialist
staff! The device must be switched off and secured against re-operation before any
electrical work is carried out!
Hint !
The dosing of the fragrance concentrate must be coupled with the function of the steam
generator. This avoids a dosing without steam. For example, lock the power output
with steam generator or by means of a temperature probe on the steam pipe.

Fragrances dosing, type DUFTDOS-0-Compact
Index: 01 Change date: 01/12/2017 Operating instructions no.: BA DW 017-01 Duftdos-0-Compact EN 17630.docx Page 11 of 21
5Commissioning
Commissioning - comments
The work described here may only be performed by appropriately trained specialist staff or by a specialist
company. Alternatively, the work may be performed by persons who have completely read and understood
the operating instructions. The systems installed must be inspected for appropriate installation and tightness
before commissioning.
Use the commissioning protocol for the commissioning procedure, see Section 9.3.
The device is provided with factory settings when it is delivered. Adapt the regulation parameters during the
start-up on the desired operating mode.
Commissioning works
Ensure that the device is appropriately installed and connected.
5.2.1 Insert the roller carrier of the hose pump
1. Remove the clipped transparent protective cover (4, not shown in image).
2. Strip the blue lock washer (2).
3. Strip the hose holder (15) from the pump housing.
Figure 6, Hose pump
Legend
11 Pump housing
12 Lock washer
13 Pressure connection
14 Suction connection
15 Hose holder with dosing pipe made of
Viton (hose set)
16 Hose
17 Roller carrier (covered by lock washer)
- Transparent protection cover (not
shown)
4. Place the yellow roller carrier (17) on the shaft
Figure 7,
Insert the roller carrier
12
11
13
14
15
16
17

Fragrances dosing, type DUFTDOS-0-Compact
Index: 01 Change date: 01/12/2017 Operating instructions no.: BA DW 017-01 Duftdos-0-Compact EN 17630.docx Page 12 of 21
5. Place the hose carrier (15) into the guide of the housing until it clicks in.
6. Turn the roller carrier (17) anticlockwise while carefully pushing the hose
into the housing until it is completely within the housing.
6. Insert the lock washer (12) again.
7. Attach the transparent protective cover again. The installation of the roller
carrier is finished.
The disassembly of the roll carrier and of the hose holder in reverse order.
5.2.2 Prepare the fragrance concentrate
CAUTION !
Many fragrance concentrates are highly flammable!
CAUTION !
Fragrance concentrates can be harmful for the health!
Wear protective gloves and protective glasses.
See the safety data sheet of the manufacturer of the fragrance.
1. Screw off the cover at the fragrance concentrate container.
2. Bore a hole with a diameter of 7mm in the cover.
3. Screw the cover again.
4. Place the container under the device.
5. Glide the suction pipe into the container so that the end of the suction pipe touches the container bottom.
5.2.3 Connect the device and aerate the dosing pipe
Realise the power supply (see Section 3.4 “Technical data“).
1. Wait until the fragrance concentrate is pumped upwards.
2. Wait until the pumped up fragrance concentrate fills the dosing pipe completely.
3. The dosing pipe is deaerated as soon as there are no air bubbles in the pipe any more.
Figure 8,
Insert the hose holder
Figure 9,
Turn the roller carrier

Fragrances dosing, type DUFTDOS-0-Compact
Index: 01 Change date: 01/12/2017 Operating instructions no.: BA DW 017-01 Duftdos-0-Compact EN 17630.docx Page 13 of 21
6Operation / handling
General
The device is ready for use after the successful commissioning.
Control
No adjustments on the control possible
Control - software
No software available
Top up consumables
CAUTION !
Fragrance concentrates can be harmful for the health!
Wear protective gloves and protective glasses.
ATTENTION !
Aggressive fragrance concentrates shorten the lifetime of the hoses.
If possible, avoid aggressive fragrance concentrates.
Hint !
Refill consumables in due time. If the container is empty, the pump sucks air and the
dosing pipe must be deaerated before continuing. Do not use any aggressive fragrance
concentrates attacking the hoses.
Fragrance concentrate
1. Screw off the cover at the fragrance concentrate container.
2. Bore a hole with a diameter of 7mm in the cover.
3. Screw the cover again.
4. Place the container under the device.
5. Glide the suction pipe into the container so that the end of the suction pipe touches the container bottom.

Fragrances dosing, type DUFTDOS-0-Compact
Index: 01 Change date: 01/12/2017 Operating instructions no.: BA DW 017-01 Duftdos-0-Compact EN 17630.docx Page 14 of 21
7Maintenance, service, faults
Device maintenance
It is recommended to task a specialist company with maintenance.
For an operation with few errors carry out the following works:
1. Clean the device in regular intervals.
2. Supply consumables and refill in due time.
3. Carry out test and maintenance works according to the maintenance protocol.
DANGER DUE TO HIGH VOLTAGE !
Before works on the device, make the device tension free and protect it against new
connection! Do not open the casing!
7.1.1 Check / replace hose set
The device is mainly maintenance free. The pump hose in the pump is subject to mechanical and chemical
stress.
Each time when the fragrance concentrate is exchanged, carry out a visual checking of the pump hose, to
detect damages in due time and to exchange the dosing hose.
Exchange the dosing hose at least each 6 months, and more frequently in case of aggressive fragrance concen-
trates.
Components of the hose dosing pump
Figure 10, Hose dosing pump SA spare parts
Legend
4 Transparent protection cover
12 Lock washer
15 Hose holder
17 Roller carrier, yellow
Changing the hose set and roller carrier
See description in Section 5.2 Commissioning work, "Insert roller carrier of the hose pump"
4
12
15
17

Fragrances dosing, type DUFTDOS-0-Compact
Index: 01 Change date: 01/12/2017 Operating instructions no.: BA DW 017-01 Duftdos-0-Compact EN 17630.docx Page 15 of 21
Replace the hose at the hose holder
ATTENTION !
The new hose must have the same colour and size as the hose removed. The hose may
not be twisted after insertion! The markings must be in front and in the middle (see
image).
1. Removing the hose set, see Section 7.1.1 “Check / replace hose set“.
2. Carefully cut open the hose ties with a sharp knife or pliers in order to exchange the dosing hose! Do not
damage the hose nipples!
3. Push the new dosing hose onto the hose nipples, so that the markers at the hose ends are in front. This
ensures that the hose is not twisted.
4. Fasten the hose ends with the hose ties and cut off the protruding parts of the hose ties.
5. Install the hose set, see Section 7.1.1 “Check / replace hose set“.
Figure 11, Hose set spare parts
Legend
16 Hose, black
15 Hose holder
31 Marking
32 Plier (2x)
7.1.2 Check the dosing valve
Some fragrance concentrates create deposits in the dosing line and the dosing valve. In this case the fragrances
dosing may be obstructed.
Check the dosing valve each 6 months or when necessary
1. Upon refilling the fragrance concentrate, some air of the pump must be sucked.
2. During the working of the fragrance pump, observe the air bubble.
3. The fragrance dosing system is in order when the air bubble is transported in the suction/pressure hose. If
the air bubble is moved only to and fro, the dosing valve is obstructed and must be cleaned.
Cleaning the dosing valve
1. Loosen the dosing hose from the dosing valve.
2. Screw out the dosing valve.
3. Wash the dosing valve with warm water or rinse it with ethyl alcohol.
4. If these steps are not successful, exchange the valve.
16
15
31
32

Fragrances dosing, type DUFTDOS-0-Compact
Index: 01 Change date: 01/12/2017 Operating instructions no.: BA DW 017-01 Duftdos-0-Compact EN 17630.docx Page 16 of 21
7.1.3 Check function of the pump
Realise the power-supply of the installation. The lock washer must rotate.
Check suction function of the pump
1. Draw the suction hose of the pump out of the container.
2. The pump must suck air, forming an air bubble in the dosing pipe.
If no air is sucked, the suction function is defect.
3. Afterwards deaerate the dosing pipe. See Section 5, Commissioning.
7.1.4 Fault removal
CAUTION !
Fragrance concentrates can be harmful for the health!
In case of works on the suction or dosing pipe, wear protection gloves or protection
glasses.
Fault table
Fault
Possible cause
Actions
The device does not connect
Power supply interrupted
Steam generator disconnected (if
coupled with steam generator)
Check the power supply
Connect steam generator
Device without function
Control board defective
Send in the device (do not open the
housing)
Dosing pump without function
Pump motor defective
Check / exchange the pump motor
No fragrance dosing
Container with fragrance con-
tainer empty
Air in the dosing pipe
Fragrance pump defective
Hose of the dosing pump defect
Roller carriers worn out
Dosing valve blocked
Fragrance concentrate dirty
Refill container
Deaerate dosing pipe
Check / exchange the pump
Exchange the hose
Exchange the roller carrier
Check / clean / exchange dosing valve
Visual check of the fragrance concen-
trate on transparency and cleanliness.
Exchange dirty concentrate

Fragrances dosing, type DUFTDOS-0-Compact
Index: 01 Change date: 01/12/2017 Operating instructions no.: BA DW 017-01 Duftdos-0-Compact EN 17630.docx Page 17 of 21
8Shutting down - Storage - Disposal
General
The device must be completely emptied or protected against frost when it is shut down!
Disposal of old part and operating materials
Thoroughly clean disassembled, contaminated parts before disposing of them.
Old parts and consumables must be disposed of according to the local valid regulations or must be recycled.
Please take note of the respective instruction on the packaging when the operating materials are subject to
specific regulations. In cases of doubt, information should be available from the institution responsible for
disposal at your place of operation.
When this is not possible, dispose of them as special waste.
Shutting down
In case of shutting down, interrupt the power supply.
Shutting down longer than 30 days
1. Interrupt the power supply.
2. Tear the suction pipe out of the fragrance concentrate container.
3. Rinse the fragrance concentrate pipes with water.
4. Dry all parts and store cleaned.
5. Remove the roller carrier of the fragrance pump so that dosing hose will not be damaged. Procedure see
Section 5.2 “Commissioning works“.
ATTENTION !
In case of new commissioning, always the instructions of the chapter “Commissioning”
and process the commissioning protocol.

Fragrances dosing, type DUFTDOS-0-Compact
Index: 01 Change date: 01/12/2017 Operating instructions no.: BA DW 017-01 Duftdos-0-Compact EN 17630.docx Page 18 of 21
9Documents
Declaration of conformity

Fragrances dosing, type DUFTDOS-0-Compact
Index: 01 Change date: 01/12/2017 Operating instructions no.: BA DW 017-01 Duftdos-0-Compact EN 17630.docx Page 19 of 21
Terminal plan
No terminal diagrams necessary
Commissioning protocol / instruction
This protocol is to be completed by the commissioning technician! All warranty claims expire when no completed and signed
commissioning protocol is available!
The commissioning protocol is included in the documents attached.

Fragrances dosing, type DUFTDOS-0-Compact
Index: 01 Change date: 01/12/2017 Operating instructions no.: BA DW 017-01 Duftdos-0-Compact EN 17630.docx Page 20 of 21
Operating data sheet
No operation data sheet necessary
Maintenance protocol
Perform the maintenance work listed in order to retain the validity of your warranty.
The maintenance protocol is included in the documents attached.