900CE Installation, Operation and Maintenance
11477-03-D Page 18 of 56 Webasto Charging Systems, Inc.
Operate If no faults have been detected, following connection to a
UUT, the system disconnects the isolation monitoring,
allows the output contactors to close, and continues to
display the ready light (green).
Reset After a fault has been detected and the cause of the fault
corrected, the unit must be reset. This can be done either
by a power-down and re-start of the unit (as would have to
be done to perform any work inside the unit) or by manually
pressing the RESET button (yellow). To clear the fault
manually, hold the reset button down for eight (8) seconds.
The light will flash while you are holding down the button.
Once the fault is cleared, the light will return to a steady
yellow indicating the circuit is ready to resume monitoring
and the 900CE lockout has been released.
2.1.3 DC Converter Functions & Controls
The DC Converter monitors load connections, processes power from the
Intermediate DC Bus for the load, and provides a local control interface for
the user. All DC converter configurations can be set either via the ROS
computer or manually through the front panel (shown in Figure 2.4).
The DC Converter is composed of two separately controllable converters,
converter A and converter B. Each converter has its own set of front panel
meters, mode select switches and output terminals.
The converter has the ability to operate in two different configurations:
Independent Configuration
Two loads can be connected and separately controlled.
External Parallel Configuration
This configuration is called parallel because internally the two converter
circuits function in parallel to provide higher current capability. When
operating in this mode, the user must use the output on both channel
terminals.
The DC Converter incorporates safety features to minimize the possibility
of an improperly connected load, or hazardous voltage exposure. The DC
Converter monitors internal switches, which indicate where load
connectors are inserted, and verifies that the load connections and the
chosen configuration are compatible.
If the load configuration requested does not match the load connections,
the requested configuration will not be acknowledged. Additionally, the
output terminals will automatically be disconnected, using internal
contactors, if one of the connectors is pulled from the unit.
The internal contactors remain disconnected during load configuration or
reconfiguration, and will also be disconnected in the event of a load fault