WEHRLE MODULARIS Composite ETK-EAX User manual

EN
Operang Instrucons
Single-Jet Dry Meter
Single-Jet Dry Meter MODULARIS
Single-Jet Dry Meter MODULARIS Composite
II
0102
23123456
2021
DE-17-MI001-PTB004
R315H/R315V
1,6MPa
ETK-EAM
T30
Q
2,5
3
Obertalstraße8
E.Wehrle GmbH
D-78120Furtwangen
M21
m
3
2,5
Q
3
DE-08-MI001-PTB018
T30
R250H/R80V
1,6MPa
³
m
2028
E
.
W
e
h
r
l
e
G
m
b
H
O
b
e
r
t
a
l
s
t
r
a
ß
e
8
D
-
7
8
1
2
0
F
u
r
t
w
a
n
g
e
n
M21
0102
23123456
2,5
Q
3
DE-08-MI001-PTB018
T30
R250H/R80V
1,6MPa
³
m
2028
E
.
W
e
h
r
l
e
G
m
b
H
O
b
e
r
t
a
l
s
t
r
a
ß
e
8
D
-
7
8
1
2
0
F
u
r
t
w
a
n
g
e
n
M21
0102
23123456
MODULARIS
ETK-EAX
ETW-EAX
MODULARIS Composite
ETK-EAX
ETW-EAX
WECOUNT
ETK-EAM
EtW-EAM

Content
Device marking WECOUNT ETK-EAM �������������������������������������4
Device marking MODULARIS ETK-EAX �����������������������������������5
Device dimensions �������������������������������������������������������������������������6
Required tools ���������������������������������������������������������������������������������6
Scope of delivery ����������������������������������������������������������������������������7
Transport ������������������������������������������������������������������������������������������7
Storage and environmental condions ��������������������������������������7
Cleaning��������������������������������������������������������������������������������������������7
Personnel qualicaon ������������������������������������������������������������������8
Intended use������������������������������������������������������������������������������������8
Safety notes and hazard warnings ����������������������������������������������9
Installing the water meter���������������������������������������������������������� 10
WECOUNT (electronic register)����������������������������������������������� 18
Display explanaon��������������������������������������������������������������������������� 18
Delivery condion����������������������������������������������������������������������������� 19
Switching to operang mode + trigger radio ������������������������������ 19
Radio sengs������������������������������������������������������������������������������������� 21
Device display loop��������������������������������������������������������������������������� 22
Event and error messages��������������������������������������������������������������� 23
WECOUNT addional funcons �������������������������������������������� 25
Device interface with communicaon head�������������������������������� 25
End-of-day value memory��������������������������������������������������������������� 26

Event logle���������������������������������������������������������������������������������������� 26
High resoluon mode ���������������������������������������������������������������������� 27
Radio sengs conguraon����������������������������������������������������������� 28
WECOUNT technical data ������������������������������������������������������� 30
Translaons ����������������������������������������������������������������������������������� 30
Maintenance��������������������������������������������������������������������������������� 31
Disposal ����������������������������������������������������������������������������������������� 31
Return��������������������������������������������������������������������������������������������� 31

EN 4 | Water meter
Device marking WECOUNT ETK-EAM
II
0102
23123456
2021
DE-17-MI001-PTB004
R315H/R315V
1,6 MPa
ETK-EAM
T30
Q
2,5
3
Obertalstraße 8
E. Wehrle GmbH
D-78120 Furtwangen
M21
m
3
A
B
C
D
E
F
G
H
I
J
K
A
CE marking
B
Year of producon
C
Type approval number
D
Measuring class/permied installaon posion RxxH: horizontal
posion, RxxV: vercal posion
E
Type marking
F
Placeholder for customized logo
G
Max� permissible pressure
H
Max� permissible water temperature
I
Meter size Q3
J
Postal address
K
Serial number

EN
Water meter | 5
A
CE marking
B
Postal address
C
Year of producon
Type marking
E
Placeholder for customized logo
F
Type approval number
G
Max� permissible pressure
H
Measuring class/permied installaon posion RxxH: horizontal
posion, RxxV: vercal posion
I
Max� permissible water temperature
J
Meter size Q3
K
Serial number
Device marking MODULARIS ETK-EAX
2,5
Q
3
DE-08-MI001-PTB018
T30
R250H/R80V
1,6 MPa
³
m
2021
ETK-EAX
E
.
W
e
h
r
l
e
G
m
b
H
O
b
e
r
t
a
l
s
t
r
a
ß
e
8
D
-
7
8
1
2
0
F
u
r
t
w
a
n
g
e
n
M21
0102
23123456
A
B
C
D
F
G
H
I
J
K
E
D

EN 6 | Water meter
Device dimensions
Required tools
16 H
L = 80 - 190 mm
H = ca� 53 mm

EN
Water meter | 7
Scope of delivery
Transport
Storage and environmental condions
Cleaning
H₂O
≤ 60% RH
+0,1°C ... +65°C
H₂O

EN 8 | For your safety
Personnel qualicaon
The water meter may only be installed or replaced by trained
specialists for sanitary, heang and air-condioning technology.
Intended use
Water meters are used to record the drinking water
consumpon, depending on the version for cold or warm
water. Other cases of applicaon that deviate from these
specicaons must be approved of in wring by
E� Wehrle GmbH�
Water meters are exclusively intended for the above-meno-
ned funcon. The conversion and any use of the water meters
dierent or beyond this is considered improper use and
therefore not permied.
Warranty is only eecve aer compliance with these
regulaons and the applicable technical rules has been proven.
XFor the period of use, observe all applicable naonal regula-
ons and in parcular the calibraon regulaon.
XDuring installaon, observe all specicaons according to
DIN EN 806 and DIN 1988, especially hygiene regulaons and
ambient temperatures�
XObserve the nominal operang condions according to the
type examinaon cercate and informaon on the devices.
XKeep these instrucons close to the meter�

EN
For your safety | 9
Safety notes and hazard warnings
Improper assembly, pressure tests, modicaons or incorrect
operaon can cause personal injury and damage to property.
XIf the seal is damaged or removed, the water meter is no longer
licenced for legal metering�
XCheck water meter for transport damage before installaon.
XDo not drop, never hold by the protecve cover or counter.
XIf the water meter has fallen down, it must not be installed
anymore�
Pressure shocks in the pipe may damage the meter!
Present air pockets falsify the measurement result�
XOnly use KTW/TVO compliant lubricants that are suitable for
EPDM gaskets�
XWater meters may only be installed aer a pressure test.
XWater meters may only be installed in pipes that have already
been leak-tested, ushed and vented and they must be well
vented before commissioning�
XMake sure that the water meter is always lled with water.

EN 10 | Installaon guide
Installing the water meter
OFF
(... )
1
2

EN
Installaon guide | 11
3
4

EN 12 | Installaon guide
5
6

EN
Installaon guide | 13
7
8

EN 14 | Installaon guide
9
10

EN
Installaon guide | 15
11
12

EN 16 | Installaon guide
Composite Version
Max. 50 Nm
13
14

EN
Installaon guide | 17
15
16

EN 18 | WECOUNT
WECOUNT (electronic register)
The following device displays are examples!
Display explanaon
A
Shows acve radio signal
B
Baery warning symbol (replace device)
C
Flow rate symbol (ashes in case of ow)
D
Current ow rate value (oponal)
E
Main display (m3), cumulave consumpon with 3
decimal places (litres)
A
B
C
D
E

EN
WECOUNT | 19
Delivery condion
The SLEEP mode is the regular delivery condion of the meter.
In this condion the meter already counts the consumpon,
with the radio transmission not yet acve to save energy
during transport and unl installaon.
Note: The end customer/installer can be sure of the meter
being a new device, when the word SLEEP is displayed.
Switching to operang mode + trigger radio
Opening a tap for a few seconds triggers the meter to switch
to operang mode. The device display changes and only now
the installaon radio starts up.
A minimum ow rate of approx. 140 L/h is necessary (e.g. for a
short me, fully open the tap).

EN 20 | WECOUNT
Installaon radio
If you have triggered the installaon radio aer installing the
meter, you can use it to check for recepon. The devices
connuously transmit the consumpon data for 72 hours at a
radio frequency of 16 seconds� This discounts the set radio
mes. Only aer that does the meter run in the normally
programmed radio operaon. The radio symbol in the display
ashes during installaon radio. During normal radio operaon
the radio signal lights up permanently�
The installaon radio can also be triggered at any me via the
Windows conguraon app, see chapter “„WECOUNT
addional funcons“ on page 25�
This manual suits for next models
5
Table of contents
Other WEHRLE Measuring Instrument manuals

WEHRLE
WEHRLE WECOUNT RTK-OPM User manual

WEHRLE
WEHRLE WECOUNT MTK-OZM User manual

WEHRLE
WEHRLE ETK-EAM User manual

WEHRLE
WEHRLE ETK-EAM User manual

WEHRLE
WEHRLE WECOUNT RTK-OPM User manual

WEHRLE
WEHRLE WECOUNT-S ETK-EAM User manual

WEHRLE
WEHRLE Inline 500 WECOUNT User manual

WEHRLE
WEHRLE WECOUNT-S User manual

WEHRLE
WEHRLE WECOUNT MTK-OZM User manual

WEHRLE
WEHRLE WECOUNT MTK-OZM User manual