WEHRLE WECOUNT RTK-OPM User manual

EN
Operang Instrucons
Piston Meter Cartridge Version
Piston Meter Cartridge Version MODULARIS
Mul-Jet Wet Meter Cartridge Version
4
Q
3
CH-MI001-09019
T30
R160H/R160V
1,6MPa
³
m
RTK-OPX
2021
M21
0102
23123456
CRI
E
.
W
e
h
r
l
e
G
m
b
H
O
b
e
r
t
a
l
s
t
r
a
ß
e
8
D
-
7
8
1
2
0
F
u
r
t
w
a
n
g
e
n
MODULARIS
RTK-OPX
Q
3
CH-MI001-10039
R80H/R50V
T30 1,6MPa
4
m³
2021
20000001
x
0
,
0
0
0
1
5
6 43
2
1
0
9
8
7
x
0
,
0
0
1
5
6 43
2
1
0
9
8
7
x
0
,
0
1
5
6 43
2
1
0
9
8
7
x
0
,
1
5
6 43
2
1
0
9
8
7
0 0 0 0 0
MNK-OPV
CRI
M21
0102
MNK-OPV
II
0102
23123456
2021
DE-19-MI001-PTB013
R160H/R160V
1,6MPa
RTK-OPM
CRI
T30
Q
4
3
Obertalstraße8
E.Wehrle GmbH
D-78120Furtwangen
M21
m
3
WECOUNT
RTK-OPM
II
0102
23123456
2021
DE-19-MI001-PTB013
R160H/R160V
1,6MPa
RTK-OPM
CRI
T30
Q
4
3
Obertalstraße8
E.Wehrle GmbH
D-78120Furtwangen
M21
m
3

Content
Device marking WECOUNT RTK-OPM�������������������������������������4
Device marking MODULARIS MNK-OPX���������������������������������5
Device marking MNK-OPV ����������������������������������������������������������6
Device design ����������������������������������������������������������������������������������7
Device dimensions �������������������������������������������������������������������������8
Required tools ���������������������������������������������������������������������������������8
Scope of delivery ����������������������������������������������������������������������������9
Transport ������������������������������������������������������������������������������������������9
Storage and environmental condions ��������������������������������������9
Cleaning��������������������������������������������������������������������������������������������9
Personnel qualicaon ��������������������������������������������������������������� 10
Intended use��������������������������������������������������������������������������������� 10
Safety notes and hazard warnings ������������������������������������������� 11
Installing the water meter���������������������������������������������������������� 12
Installing the measuring cartridge�������������������������������������������� 20
WECOUNT (electronic register)����������������������������������������������� 28
Display explanaon��������������������������������������������������������������������������� 28
Delivery condion����������������������������������������������������������������������������� 29
Switching to operang mode + trigger radio ������������������������������ 29
Radio sengs������������������������������������������������������������������������������������� 31
Device display loop��������������������������������������������������������������������������� 32
Event and error messages��������������������������������������������������������������� 33

WECOUNT addional funcons �������������������������������������������� 35
Device interface with communicaon head�������������������������������� 35
End-of-day value memory��������������������������������������������������������������� 36
Event logle���������������������������������������������������������������������������������������� 36
High resoluon mode ���������������������������������������������������������������������� 37
Radio sengs conguraon����������������������������������������������������������� 38
WECOUNT technical data ������������������������������������������������������� 40
Translaons ����������������������������������������������������������������������������������� 40
Maintenance��������������������������������������������������������������������������������� 41
Disposal ����������������������������������������������������������������������������������������� 41
Return��������������������������������������������������������������������������������������������� 41

EN 4 | Water meter
Device marking WECOUNT RTK-OPM
II
0102
23123456
2021
DE-19-MI001-PTB013
R160H/R160V
1,6 MPa
RTK-OPM
CRI
T30
Q
4
3
Obertalstraße 8
E. Wehrle GmbH
D-78120 Furtwangen
M21
m
3
A
B
C
D
E
F
G
H
I
J
K
L
A
CE marking
B
Year of producon
C
Type approval number
D
Measuring class/permied installaon posion RxxH: horizontal
posion, RxxV: vercal posion
E
Type marking
F
Placeholder for customized logo
G
Max. permissible pressure
H
Max. permissible water temperature
I
Meter size Q3
J
Postal address
K
Serial number

EN
Water meter | 5
A
Postal address
B
Year of producon
C
Type marking
D
Placeholder for customized logo
E
Type approval number
F
Max. permissible pressure
G
Measuring class/permied installaon posion RxxH: horizontal
posion, RxxV: vercal posion
H
Max. permissible water temperature
I
Meter size Q3
Serial number
CE marking
Meter type
J
K
L
Device marking MODULARIS MNK-OPX
4
Q
3
CH-MI001-09019
T30
R160H/R160V
1,6 MPa
³
m
RTK-OPX
2021
M21
0102
23123456
CRI
E
.
W
e
h
r
l
e
G
m
b
H
O
b
e
r
t
a
l
s
t
r
a
ß
e
8
D
-
7
8
1
2
0
F
u
r
t
w
a
n
g
e
n
A
B
C
D
E
F
G
H
I
J
K
L
L

EN 6 | Water meter
A
Serial number
B
Type approval number
C
Measuring class/permied installaon posion RxxH: horizontal
posion, RxxV: vercal posion
D
Max. permissible pressure
E
Max. permissible water temperature
F
Meter size Q3
G
10 liter scala
H
Meter type
I
Type marking
CE marking
Year of producon
J
K
Device marking MNK-OPV
Q3
CH-MI001-10039
R80H/R50V
T30 1,6 MPa
4
m³
2021
20000001
x
0
,
0
0
0
1
5
6 43
2
1
0
9
8
7
x
0
,
0
0
1
5
6 43
2
1
0
9
8
7
x
0
,
0
1
5
6 43
2
1
0
9
8
7
x
0
,
1
5
6 43
2
1
0
9
8
7
0 0 0 0 0
MNK-OPV
CRI
M21
0102
A
B
C
D
E
G
H
I
J
K
F

EN
Water meter | 7
Device design
G
A
B
C
D
E
F
I
H
A
Alternavely with protecve cover (consisng of protecve ring
and protecve cover)
B
Cartridge screw connecon
C
Head screwed O-ring
D
Measuring cartridge O-ring
E
Measuring cartridge
F
O-ring (already mounted onto cartridge)
G
Housing according to DIN EN 14154
H
Backow preventer (BFP) oponal
I
O-ring seang (also available without BFP)

EN 8 | Water meter
Device dimensions
Required tools
L = 190 mm
H = 106 - 122 mm
L = 105 mm
H = 164 - 178 mm

EN
Water meter | 9
Scope of delivery
Transport
Storage and environmental condions
Cleaning
H₂O
≤ 60% RH
+0,1°C ... +65°C
H₂O
Enre meter
CRI
CRI
Measuring cartridge

EN 10 | For your safety
Personnel qualicaon
The water meter may only be installed or replaced by trained
specialists for sanitary, heang and air-condioning technology.
Intended use
Water meters are used to record the drinking water
consumpon, depending on the version for cold or warm
water. Other cases of applicaon that deviate from these
specicaons must be approved of in wring by
E. Wehrle GmbH.
Water meters are exclusively intended for the above-meno-
ned funcon. The conversion and any use of the water meters
dierent or beyond this is considered improper use and
therefore not permied.
Warranty is only eecve aer compliance with these
regulaons and the applicable technical rules has been proven.
XFor the period of use, observe all applicable naonal regula-
ons and in parcular the calibraon regulaon.
XDuring installaon, observe all specicaons according to
DIN EN 806 and DIN 1988, especially hygiene regulaons and
ambient temperatures.
XObserve the nominal operang condions according to the
type examinaon cercate and informaon on the devices.
XKeep these instrucons close to the meter�

EN
For your safety | 11
Safety notes and hazard warnings
Improper assembly, pressure tests, modicaons or incorrect
operaon can cause personal injury and damage to property.
XIf the seal is damaged or removed, the water meter is no longer
licenced for legal metering�
XCheck water meter for transport damage before installaon.
XDo not drop, never hold by the protecve cover or counter.
XIf the water meter has fallen down, it must not be installed
anymore�
Pressure shocks in the pipe may damage the meter!
Present air pockets falsify the measurement result�
XOnly use KTW/TVO compliant lubricants that are suitable for
EPDM gaskets.
XWater meters may only be installed aer a pressure test.
XWater meters may only be installed in pipes that have already
been leak-tested, ushed and vented and they must be well
vented before commissioning.
XMake sure that the water meter is always lled with water.

EN 12 | Installaon guide
Installing the water meter
OFF
(... )
1
2

EN
Installaon guide | 13
3
4

EN 14 | Installaon guide
5
6

EN
Installaon guide | 15
7
8

EN 16 | Installaon guide
9
10

EN
Installaon guide | 17
11
12

EN 18 | Installaon guide
Composite Version
Max. 50 Nm
13
14

EN
Installaon guide | 19
15
16

EN 20 | Measuring cartridge assembly
Installing the measuring cartridge
1
2
OFF
(... )
Other manuals for WECOUNT RTK-OPM
1
This manual suits for next models
4
Table of contents
Other WEHRLE Measuring Instrument manuals

WEHRLE
WEHRLE WECOUNT-S User manual

WEHRLE
WEHRLE WECOUNT MTK-OZM User manual

WEHRLE
WEHRLE WECOUNT-S ETK-EAM User manual

WEHRLE
WEHRLE ETK-EAM User manual

WEHRLE
WEHRLE WECOUNT MTK-OZM User manual

WEHRLE
WEHRLE Inline 500 WECOUNT User manual

WEHRLE
WEHRLE WECOUNT RTK-OPM User manual

WEHRLE
WEHRLE ETK-EAM User manual

WEHRLE
WEHRLE MODULARIS Composite ETK-EAX User manual

WEHRLE
WEHRLE WECOUNT MTK-OZM User manual