WEHRLE WECOUNT-S User manual

EN
Operang Instrucons
Mul-Jet Dry Meter Measuring Capsules
WECOUNT-S
MTK-OZM
MTW-OZM
II
0102
1,6 MPa
2022
DE-20-MI001-PTB001
R160H/R160V LGS
MTK-OZM
IST
LoRa
T30
Q
2,5
3
Obertalstraße8
E.Wehrle GmbH
D-78120Furtwangen
M22
m
3
2418C0000002
8 WEH00 6600 0006
II
0102
8 WEH00 6600 0002
1,6 MPa
2022
DE-20-MI001-PTB001
R160H/R160V LGS
2418C0000002
LoRa
MTK-OZM
IST
T30
Q
2,5
3
Obertalstraße8
E.Wehrle GmbH
D-78120Furtwangen
M22
m
3
II
0102
8 WEH00 6600 0002
1,6 MPa
2022
DE-20-MI001-PTB001
R160H/R160V LGS
2418C0000002
LoRa
MTK-OZM
IST
T30
Q
2,5
3
Obertalstraße8
E.Wehrle GmbH
D-78120Furtwangen
M22
m
3

Content
Overview Measuring Capsules ����������������������������������������������������4
Device marking WECOUNT-S MTK-OZM �������������������������������5
Device dimensions �������������������������������������������������������������������������7
Required tools ���������������������������������������������������������������������������������7
Scope of delivery ����������������������������������������������������������������������������8
Transport ������������������������������������������������������������������������������������������8
Storage and environmental condions ��������������������������������������8
Cleaning ��������������������������������������������������������������������������������������������8
Personnel qualicaon ������������������������������������������������������������������9
Intended use ������������������������������������������������������������������������������������9
Safety notes and hazard warnings ������������������������������������������� 10
Installing the water meter ���������������������������������������������������������� 11
WECOUNT-S (electronic register) ������������������������������������������� 17
Display explanaon��������������������������������������������������������������������������� 17
Delivery condion ����������������������������������������������������������������������������� 18
Switching to operang mode + trigger radio ������������������������������ 18
Radio sengs ������������������������������������������������������������������������������������� 20
Device display loop ��������������������������������������������������������������������������� 21
Event and error messages ���������������������������������������������������������������22

WECOUNT-S addional funcons ����������������������������������������� 24
NFC (Near Field Communicaon)
Device interface �������������������������������������������������������������������������������� 25
Data memory ������������������������������������������������������������������������������������ 27
Volume readings/15 month end values ��������������������������������������� 27
LCD sengs ��������������������������������������������������������������������������������������� 27
Event logle ���������������������������������������������������������������������������������������� 28
High resoluon mode ���������������������������������������������������������������������� 29
Radio sengs conguraon ����������������������������������������������������������� 30
WECOUNT-S technical data ���������������������������������������������������� 32
Translaons ����������������������������������������������������������������������������������� 32
Maintenance ��������������������������������������������������������������������������������� 33
Disposal ����������������������������������������������������������������������������������������� 33
Return��������������������������������������������������������������������������������������������� 33

EN 4 | Water meter
WECOUNT-S: electronic water meter (WC = Composite/WM = Brass)
MODULARIS: mechanical water meter (MC = Composite/MM = Brass)
IST
TE1 MET
MOC/MOE
MUK
WGU
WE1
MB3
HT2
MB2
A34
DM1
WC WM
M C MM
X
X
WC WM
M C MM
X
X
WC WM
M C MM
X
X
WC WM
M C X MM
XWC WM
M C MM
X
X
WC WM
M C MM
X
X
WC WM
M C MM
X
X
WC WM
M C MM
X
X
WC WM
M C MM
X
X
WC WM
M C MM
X
X
WC WM
M C MM
X
X
WC WM
M C MM
X
X
Overview Measuring Capsules

EN
Water meter | 5
Device marking WECOUNT-S MTK-OZM
II
0102
8 WEH00 6600 0002
1,6 MPa
2022
DE-20-MI001-PTB001
R160H/R160V LGS
2418C0000002
LoRa
MTK-OZM
IST
T30
Q
2,5
3
Obertalstraße 8
E. Wehrle GmbH
D-78120 Furtwangen
M22
m
3
P
Q
R
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
A
CE marking
B
Posi on of the local NFC interface
C
Serial number
D
Max� permissible pressure
E
Year of produc on
F
Type approval number
G
Placeholder for 2D data matrix code (key management pla orm)
H
Counter version 8/L = 868 MHz (wMbus-) / LoRa radio,
G/K=Large/Small ba ery, S=WECOUNT-S
I
Measuring class/permi ed installa on posi on RxxH: horizontal
posi on, RxxV: ver cal posi on

EN 6 | Water meter
J
DevEUI / MAC address (op onal for LoRa radio version)
Placeholder for customized logo
Meter type marking
M
Meter type interface
N
Radio standard (wMbus, LoRa)
O
Max� permissible water temperature
P
Meter size Q3
Q
Placeholder for 2D data matrix code (e�g� serial number)
R
Postal address
K
L

EN
Water meter | 7
Device dimensions
Required tools
H = 35 - 65 mm

EN 8 | Water meter
Scope of delivery
Transport
Storage and environmental condions
Cleaning
MB2
H₂O
≤ 60% RH
+0,1°C ... +65°C
H₂O

EN
For your safety | 9
Personnel qualicaon
The water meter may only be installed or replaced by trained
specialists for sanitary, heang and air-condioning technology�
Intended use
Water meters are used to record the drinking water
consumpon, depending on the version for cold or warm
water� Other cases of applicaon that deviate from these
specicaons must be approved of in wring by
E� Wehrle GmbH�
Water meters are exclusively intended for the above-meno-
ned funcon� The conversion and any use of the water meters
dierent or beyond this is considered improper use and
therefore not permied�
Warranty is only eecve aer compliance with these
regulaons and the applicable technical rules has been proven�
XFor the period of use, observe all applicable naonal regula-
ons and in parcular the calibraon regulaon�
XDuring installaon, observe all specicaons according to
DIN EN 806 and DIN 1988, especially hygiene regulaons and
ambient temperatures�
XObserve the nominal operang condions according to the
type examinaon cercate and informaon on the devices�
XKeep these instrucons close to the meter�

EN 10 | For your safety
Safety notes and hazard warnings
Improper assembly, pressure tests, modicaons or incorrect
operaon can cause personal injury and damage to property�
XIf the seal is damaged or removed, the water meter is no longer
licenced for legal metering�
XCheck water meter for transport damage before installaon�
XDo not drop, never hold by the protecve cover or counter�
XIf the water meter has fallen down, it must not be installed
anymore�
Pressure shocks in the pipe may damage the meter!
Present air pockets falsify the measurement result�
XOnly use KTW/TVO compliant lubricants that are suitable for
EPDM gaskets�
XWater meters may only be installed aer a pressure test�
XWater meters may only be installed in pipes that have already
been leak-tested, ushed and vented and they must be well
vented before commissioning�
XMake sure that the water meter is always lled with water�

EN
Installaon guide | 11
Installing the water meter
OFF
( ... )
WGU
HT2
!
1
2

EN 12 | Installaon guide
AB
3
4

EN
Installaon guide | 13
5
6

EN 14 | Installaon guide
AB
IST, MUK, MET,
MOC/MOE
KTW/TVO/
EPDM conform!
KTW/TVO/
EPDM conform!
7
8

EN
Installa on guide | 15
A
B
MB2
IST, TE1, MET, MOC/MOE
max. 40 Nm
A34, DM1, MUK, HT2, MB2,
MB3, WE1, WGU
max. 80 Nm
9
10

EN 16 | Installaon guide
ON
(... )
ON
11

EN
WECOUNT-S | 17
WECOUNT-S (electronic register)
The following device displays are examples!
Display explana on
A
Shows ac ve radio signal
B
Ba ery warning symbol (replace device)
C
Flow rate symbol ( ashes in case of ow)
D
Current ow rate value (op onal)
E
Main display (m3), cumula ve consump on with 3
decimal places (litres)
A
B
C
D
E

EN 18 | WECOUNT-S
Delivery condi on
The SLEEP mode is the regular delivery condion of the meter�
In this condion the meter already counts the consumpon,
with the radio transmission not yet acve to save energy
during transport and unl installaon�
Note: The end customer/installer can be sure of the meter
being a new device, when the word SLEEP is displayed�
Switching to opera ng mode + trigger radio
Opening a tap for a few seconds triggers the meter to switch
to operang mode� The device display changes and only now
the installaon radio starts up�

EN
WECOUNT-S | 19
The minimum volume of 5 l (standard) must be removed (e�g�
turn on the tap completely for a short me)� The minimum
volume can be adjusted at the factory or via NFC interface�
When switching to normal operaon from SLEEP mode, the
commissioning date is set, the volume is reset and the error log
is deleted� The unit can also be switched to operang mode via
the NFC interface with the WEPROG soware on an Android
or Windows device�
Installaon radio
If you have triggered the installaon radio aer installing the
meter, you can use it to check the recepon�
In the rst hour aer commissioning, the transmission interval
is 30 seconds� Aer this me, the congured interval is
acvated� Regardless of the congured radio mes, the radio
remains on for 24h unl the 3rd midnight crossing� Aer this
me, the radio calendar is used� During regular radio operaon,
the radio symbol in the display lights up permanently�

EN 20 | WECOUNT-S
Radio sengs
As soon as the radio is acvated, it sends an encrypted radio
telegram according to OMS (Open Metering System)� During
acve radio mes, the radio symbol lights up permanently�
Factory seng = Long telegram „Walk-by“ in C1 mode: Current
value + due date value + 15 month-end values in Mode 5 AES
encrypon
In factory seng, the radio signal is transmied in 1 minute
intervals from Monday to Friday, 6:00 am – 7:00 pm�
If other transmission mes and/or a dierent radio telegram
are desired, these can be congured using an NFC read/write
head or an NFC-capable smartphone and the WEPROG
soware, see chapter „Radio sengs conguraon“ on page
30�
Aenon!
At the request of the customer, the meter can also be
programmed with other radio sengs as default.
This manual suits for next models
2
Table of contents
Other WEHRLE Measuring Instrument manuals

WEHRLE
WEHRLE WECOUNT RTK-OPM User manual

WEHRLE
WEHRLE MODULARIS Composite ETK-EAX User manual

WEHRLE
WEHRLE WECOUNT MTK-OZM User manual

WEHRLE
WEHRLE Inline 500 WECOUNT User manual

WEHRLE
WEHRLE WECOUNT-S ETK-EAM User manual

WEHRLE
WEHRLE ETK-EAM User manual

WEHRLE
WEHRLE WECOUNT RTK-OPM User manual

WEHRLE
WEHRLE WECOUNT MTK-OZM User manual

WEHRLE
WEHRLE WECOUNT MTK-OZM User manual

WEHRLE
WEHRLE ETK-EAM User manual