weintek cMT-G01 series User manual

User Manual V1.0.0

Table of Contents
Overview........................................................................................................................................ 1Chapter1.
1.1. Specification....................................................................................................................................... 1
1.2. Dimensions......................................................................................................................................... 2
1.3. Connector pin designations ............................................................................................................... 4
1.4. Restoring factory default ................................................................................................................... 4
1.5. LED indicator ...................................................................................................................................... 5
1.6. Battery................................................................................................................................................ 6
1.7. Power connection .............................................................................................................................. 6
cMT-G01/G02 System Setting ....................................................................................................... 7Chapter2.
2.1. Search for cMT-G01/G02’s IP address ............................................................................................... 7
2.2. Set in internet browser ...................................................................................................................... 7
2.3. System Setting.................................................................................................................................... 8
2.3.1. Network ......................................................................................................................................... 8
2.3.2. Wi-Fi (cMT-G02)............................................................................................................................. 9
2.3.3. Date/Time...................................................................................................................................... 9
2.3.4. HMI Name.................................................................................................................................... 10
2.3.5. History.......................................................................................................................................... 10
2.3.6. Email ............................................................................................................................................ 11
2.3.7. Project Management ................................................................................................................... 12
2.3.8. System Password ......................................................................................................................... 12
2.3.9. Enhanced Security ....................................................................................................................... 13
2.3.10. EasyAccess 2.0 ............................................................................................................................. 13
2.3.11. OPA UA ........................................................................................................................................ 14
2.3.12. Communication ........................................................................................................................... 14
Updating Web Package and OS ................................................................................................... 15Chapter3.
3.1 Updating Web Package .................................................................................................................... 15
3.2 Updating OS ..................................................................................................................................... 16
How to create a cMT-G01/G02 project ....................................................................................... 18Chapter4.
4.1. Create a new project........................................................................................................................ 18
4.2. Download project to cMT-G01/G02 ................................................................................................ 20
4.3. Monitoring OPC UA Client................................................................................................................ 21
4.4. On-line/Off-line Simulation.............................................................................................................. 21
Functions supported by cMT-G01/G02 ....................................................................................... 23Chapter5.
OPC UA Web Management Interface.......................................................................................... 24Chapter6.
6.1. Introduction ..................................................................................................................................... 24
6.2. Startup / Shut Down ........................................................................................................................ 25
6.3. Server Settings ................................................................................................................................. 25

UM017003_cMT-G01G02_UserManual
V1.0.0
1
6.4. Edit Node.......................................................................................................................................... 27
6.5. Certificates ....................................................................................................................................... 28
6.6. Discovery.......................................................................................................................................... 29
6.7. Advanced.......................................................................................................................................... 30

UM017003_cMT-G01G02_UserManual
V1.0.0
1
OverviewChapter1.
1.1. Specification
IIoT Gateway
Features
Supports OPC UA
Supports MQTT
Supports MODBUS TCP/IP Gateway
Compact Design and DIN-rail
Mountable
Fan-less Cooling System
Built-in 256 MB Flash Memory
Supports MPI 187.5K
Built-in Power Isolator
cMT-G02 supports Wi-Fi
Model
cMT-G01
cMT-G02
Memory
Flash
256 MB
RAM
256 MB
Processor
32 bits RISC Cortex-A8 600MHz
I/O Port
SD Card Slot
N/A
USB Host
N/A
USB Client
N/A
Ethernet
10/100/1000 Base-T x 1
WiFi IEEE 802.11 b/g/n
10/100 Base-T x 1
10/100 Base-T x 1
COM Port
COM1: RS-232 2W, COM2: RS-485 2W/4W, COM3: RS-485 2W
RS-485 Built-in Isolation
N/A
CAN Bus
N/A
HDMI
N/A
Audio Output
N/A
Video Input
N/A
RTC
Built-in
Power
Input Power
24±20%VDC
10.5~28VDC
Power Isolation
Built-in
Power Consumption
230mA@24VDC
230mA@12VDC;
115mA@24VDC
Voltage Resistance
500VAC (1 min.)
Isolation Resistance
Exceed 50Mat 500VDC
Vibration Endurance
10 to 25Hz (X, Y, Z direction 2G 30 minutes)
Specification
PCB Coating
Yes
Enclosure
Plastic
Dimensions WxHxD
109 x 81 x 27 mm
Weight
Approx. 0.14 kg
Mount
35 mm DIN rail mounting
Environment
Protection Structure
IP20
Storage Temperature
-20°~ 60°C (-4°~ 140°F)
Operating Temperature
0°~ 50°C (32°~ 122°F)
Relative Humidity
10% ~ 90% (non-condensing)
Certificate
CE
CE marked
UL
cULus Listed
Application in progress
Software
EasyBuilder Pro V5.06.01
EasyBuilder Pro V6.00.01

UM017003_cMT-G01G02_UserManual
V1.0.0
2
1.2. Dimensions
cMT-G01
a
LAN 2 Port (10M/100M)
b
LAN 1 Port (10M/100M/1G)
c
COM1: RS-232 2W
COM2: RS-485 2W/4W
COM3: RS-485 2W
d
Power Connector
e
Default Button
英文版 簡中版 日文版
正面図 側面図
上面図 下面図
27mm [1.06"]
109mm [4.29"]
81mm [3.19"]
a
b
c
d
e
Front View Side View
Top View Bottom View
27mm [1.06"]
109mm [4.29"]
81mm [3.19"]
a
b
c
d
e
27mm [1.06"]
109mm [4.29"]
81mm [3.19"]
a
b
c
d
e

UM017003_cMT-G01G02_UserManual
V1.0.0
3
cMT-G02
a
Wi-Fi
b
LAN 1 Port (10M/100M)
c
COM1: RS-232 2W
COM2: RS-485 2W/4W
COM3: RS-485 2W
d
Power Connector
e
Default Button

UM017003_cMT-G01G02_UserManual
V1.0.0
4
1.3. Connector pin designations
COM1 RS-232, COM2 RS-485 2W/4W, COM3 RS-485 2W 9 Pin, Male, D-sub
PIN#
COM1 RS-232
COM2 RS-485
COM3 RS-485
2W
4W
1
Data+
2
RxD
3
TxD
4
Data-
5
GND
6
Data+
RX+
7
Data-
RX-
8
TX+
9
TX-
1.4. Restoring factory default
Press and hold on the Default button on the unit for more than 15 seconds to restore factory
default.
The IP setting will be restored to default:
cMT-G01:
Ethernet 1: DHCP
Ethernet 2: 192.168.100.1
cMT-G02
Wi-Fi: DHCP
Ethernet: DHCP
Please note that the projects and data stored in the unit are all cleared after pressing the Default
button.

UM017003_cMT-G01G02_UserManual
V1.0.0
5
1.5. LED indicator
LED indicators show the status of IIoT Gateway.
cMT-G01
Icon
Color
Meaning
Blue
LAN 1 Communication Status
Blue
LAN 2 Communication Status
Orange
Power Status
Green
Helps the operator to find the cMT-G01. Triggering system register LB-11959
can turn this indicator on/off. Blink LED function in Web/Download interface
can also control this indicator.
cMT-G02
Icon
Color
Meaning
Blue
LAN Communication Status
Orange
Power Status
Green
Helps the operator to find the cMT-G02. Triggering system register LB-11959
can turn this indicator on/off. Blink LED function in Web/Download interface
can also control this indicator.
Note: The second LED indicator from the left is reserved.

UM017003_cMT-G01G02_UserManual
V1.0.0
6
1.6. Battery
IIoT Gateway requires a CR1220 lithium battery to keep the RTC running.
1.7. Power connection
Power: The unit can be powered by DC power only, the voltage range is compatible with most
controller DC systems. The power conditioning circuitry inside the unit is accomplished by a
switching power supply. The peak starting current can be as high as 500mA.
cMT-G01 voltage range: 24±20% VDC
cMT-G02 voltage range: 10.5~28 VDC
Note: Connect positive DC line to the‘+’terminal and the DC ground to the‘-’terminal.

UM017003_cMT-G01G02_UserManual
V1.0.0
7
cMT-G01/G02 System SettingChapter2.
Connect cMT-G01/G02 via Ethernet cable, and then configure system settings by using web
interface.
2.1. Search for cMT-G01/G02’s IP address
Launch UtilityManagerEX, select a cMT Series model, and then select a function from Reboot,
Download, or Upload. The cMT Series HMI model or cMT-G01/G02 can be found in the IP/HMI
Name groupbox by using the model’s IP address, even if the PC or laptop is not on the same
network. UtilityManagerEX can find and change cMT-G01/G02’s IP address. The following settings
can be carried out after obtaining the IP address.
2.2. Set in internet browser
Open internet browser (IE, Chrome, or Firefox), and enter cMT-G01/G02’s IP address (for example:
192.168.100.1) to configure cMT-G01/G02.
The default IP: Ethernet 1: DHCP, Ethernet 2: 192.168.100.1
cMT-G01/G02 system information is shown in the Login page.
Icon
Description
Displays HMI name.

UM017003_cMT-G01G02_UserManual
V1.0.0
8
Displays system date.
Displays system time.
2.3. System Setting
The following part introduces cMT-G01/G02 system settings.
Three levels of privileges can be found:
[System Setting]: Controls all the settings
[Update]: Controls limited items.
[History]: Downloads history data (Recipes and Event Logs).
2.3.1. Network
Configure Ethernet ports: IP, Mask, Gateway, and DNS.
cMT-G01 has two Ethernet ports. The default IP address of Ethernet 1 is DHCP, and the static IP
address of Ethernet 2 is 192.168.100.1.
cMT-G02 has one Ethernet port, and is assigned from DHCP by default.

UM017003_cMT-G01G02_UserManual
V1.0.0
9
2.3.2. Wi-Fi (cMT-G02)
Enable/Disable Wi-Fi and related settings: search for AP, configuring IP, Mask, Gateway, and DNS.
2.3.3. Date/Time
Set RTC date and time. Select [Sync. with host] and then click [Save] to synchronize cMT-G01/G02
time with the computer time.

UM017003_cMT-G01G02_UserManual
V1.0.0
10
2.3.4. HMI Name
Enter a name to identify the unit.
[Identification light]: The green LED indicator of the unit will flash three times when this
button is clicked, helping user to find the unit.
2.3.5. History
This tab offers settings related to historical data.

UM017003_cMT-G01G02_UserManual
V1.0.0
11
[Clear]: Clears history data.
[Backup]: Downloads history data in the unit to this computer.
2.3.6. Email
This tab offers settings related to email.
[SMTP]: Configure email server and relevant settings.
[Contacts]: Set email contacts in this tab.
[Update Email Contacts]: Import the email contacts built using Administrator Tools.

UM017003_cMT-G01G02_UserManual
V1.0.0
12
2.3.7. Project Management
This tab offers settings related to project management.
[Restart Project]: Restart cMT-G01/G02 project.
[Update Project]: Upload the project’s *.cxob file to cMT-G01/G02.
[Backup Project]: Backup the project file to this computer.
2.3.8. System Password
Set login password and the password for transferring project file.

UM017003_cMT-G01G02_UserManual
V1.0.0
13
2.3.9. Enhanced Security
The account setting in this tab can determine the accounts that can log in OPC UA.
[Accounts]: Add user or change user password and operable classes.
[Import User Account]: Import the user accounts built in Administrator Tools.
2.3.10. EasyAccess 2.0
This tab shows Hardware Key, EasyAccess 2.0 activate status, and proxy settings.
For more information on EasyAccess 2.0, please see EasyAccess 2.0 User Manual.

UM017003_cMT-G01G02_UserManual
V1.0.0
14
2.3.11. OPA UA
Configure OPC UA settings. Please see Chapter 6 in this manual for more information.
2.3.12. Communication
This tab displays the communication parameters of the device connected to cMT-G01/G02. The
parameters can be changed.
Parameter list for the device connected via Serial Port.
English
Interface
Baud rate
Data Bits
Parity
Stop Bits
Timeout
Parameter 1
Parameter 2
Send ACK Delay
Parameter list for the device connected via Ethernet Port.
English
IP Address
Port
Timeout
Turnaround Delay
Parameter 1
Parameter 2
Send ACK Delay

UM017003_cMT-G01G02_UserManual
V1.0.0
15
Updating Web Package and OSChapter3.
cMT-G01/G02 Web Package and OS can be updated through Ethernet. Launch Utility ManagerEX,
select [cMT Series] » [Maintenance] » [cMT-G01 OS Upgrade].
3.1 Updating Web Package
1. Select an HMI to update OS.
2. Select [Web package] and browse for the source file.
3. Click [Update].

UM017003_cMT-G01G02_UserManual
V1.0.0
16
3.2 Updating OS
1. Select an HMI to update OS.
2. Select [OS], a Warning message shows, please read this message carefully before you click [OK].
3. If you click [OK], the cMT-G01 OS Update window opens again, browse for the source file, and
then click [Update].
4. The message window below opens, please do not turn off the power while upgrading.
5. When finished, cMT-G01 OS Update window shows “finished”.

UM017003_cMT-G01G02_UserManual
V1.0.0
17
Other manuals for cMT-G01 series
2
This manual suits for next models
1
Table of contents
Other weintek Gateway manuals
Popular Gateway manuals by other brands

Inseego
Inseego SKYUS 160 Series quick start guide

Pace
Pace HomePortal 5168NV manual

DEUTSCHMANN AUTOMATION
DEUTSCHMANN AUTOMATION UNIGATE IC - LONWorks instruction manual

Efficient Networks
Efficient Networks SpeedStream 6200 user guide

Inseego
Inseego SKYUS 100B Series user guide

Moxa Technologies
Moxa Technologies Mgate MB3660 user manual