weintek cMT-SVR-100 User manual

User
Manual
cMT-SVR Startup Guide

Table of Contents
Chapter 1 Overview............................................................................................................................................. 1
1.1 Specification....................................................................................................................................... 1
1.2 Dimensions......................................................................................................................................... 2
1.3 Connector pin designations ............................................................................................................... 4
1.4 USB host port and SD card slot .......................................................................................................... 4
1.5 Ethernet port...................................................................................................................................... 4
1.6 DIP switch........................................................................................................................................... 4
1.7 LED indicator ...................................................................................................................................... 5
1.8 CR1225 battery .................................................................................................................................. 5
1.9 Power connection .............................................................................................................................. 5
1.10 How to update cMT-SVR OS image.................................................................................................... 5
Chapter 2 System Setting .................................................................................................................................... 7
2.1 cMT-SVR System Setting .................................................................................................................... 8
2.1.1 Information.................................................................................................................................... 8
2.1.2 System Setting ............................................................................................................................... 9
Chapter 3 How to create a cMT-SVR project..................................................................................................... 16
3.1 Create a new project........................................................................................................................ 16
3.2 Download project to cMT-SVR......................................................................................................... 17
Chapter 4 cMT Viewer App ............................................................................................................................... 18
4.1 Introduction of icons........................................................................................................................ 18
4.2 How to load project file to cMT Viewer........................................................................................... 19
4.3 How to open cMT Viewer settings page .......................................................................................... 22
4.4 Monitor Mode.................................................................................................................................. 28

cMT-SVR Startup Guide
UM015002E_20190123 Copyright© 2019 Weintek Lab., Inc. All rights reserved.
1
Chapter 1 Overview
1.1 Specification

UM015002E_20190123 Copyright© 2019 Weintek Lab., Inc. All rights reserved.
2
1.2 Dimensions
cMT-SVR-100/102
a
USB Host Port
e
Power Connector
b
Ethernet 2 Port
f
SD Card Slot
c
Ethernet 1 Port
g
DIP Switch
d
COM1 RS-232, COM2 RS-485 2W/4W,
COM3 RS-485 2W
h
Reset Button
27,00
[1,063]
125,00
[4,921]
115
[4,520]
130
[5,107]
Front View Side View
Top View Bottom View
簡中版 英文版
27,00
[1,063]
125,00
[4,921]
115
[4,520]
130
[5,107]
g
h
a
f
g
h
b
c
d
e
a
b
c
d
e
f

UM015002E_20190123 Copyright© 2019 Weintek Lab., Inc. All rights reserved.
3
cMT-SVR-200/202
a
Wi-Fi
e
Power Connector
b
USB Host Port
f
SD Card Slot
c
Ethernet Port
g
DIP Switch
d
COM1 RS-232, COM2 RS-485 2W/4W,
COM3 RS-485 2W
h
Reset Button
英文版 簡中版 日文版
正面図 側面図
上面図 下面図
b
c
d
e
a
130mm [5.11"]
115mm [4.52"]
Side View
125mm [4.92"]
27mm [1.06"]
Front View
Top View
f
g
h
b
c
d
e
f
a
130mm [5.11"]
115mm [4.52"]
125mm [4.92"]
27mm [1.06"]
g
h
i
b
c
d
e
f
a
130mm [5.11"]
115mm [4.52"]
125mm [4.92"]
27mm [1.06"]
g
h
i
Bottom View

UM015002E_20190123 Copyright© 2019 Weintek Lab., Inc. All rights reserved.
4
1.3 Connector pin designations
PIN#
COM1 RS-232
COM2 RS-485
COM3 RS-485
2W
4W
1
Data+
2
RxD
3
TxD
4
Data-
5
Ground
6
Data+
RX+
7
Data-
RX-
8
TX+
9
TX-
1.4 USB host port and SD card slot
USB 2.0 full speed host interface supports barcode scanners and USB drive. While using external
hard drive, use external power supply. Do not use USB port to charge external device. You may use
SD card as an expansion of storage.
1.5 Ethernet port
The unit has one/two 10/100/1000M Gigabit Ethernet ports.
The LED indicators on the Ethernet port indicate:
Orange LED: LAN link status
Green LED: Active communication status
1.6 DIP switch
Each unit is equipped with a reset button and a set of DIP switches. When using the DIP switches to
change modes, the corresponding functions will be triggered.
When SW1 is turned ON and power the unit again, the IP setting is restored to default:
cMT-SVR-100/102
Ethernet 1: DHCP
Ethernet 2: 192.168.100.1
cMT-SVR-200/202
Ethernet 1: DHCP
Wi-Fi: DHCP
Note: Reboot cMT-SVR after adjusting DIP switches to start the corresponding mode. When restore
factory default, the project file and history data stored in the unit are all cleared.
SW1
SW2
Mode
OFF
OFF
Normal mode
ON
OFF
Restore Ethernet IP settings
OFF
ON
Boot loader mode
ON
ON
Restore factory default

UM015002E_20190123 Copyright© 2019 Weintek Lab., Inc. All rights reserved.
5
1.7 LED indicator
LED indicators show the operation status of cMT-SVR.
Power (Orange)
Indicates power status.
CPU (Green)
Indicates CPU status.
Communication (Blue)
Indicates communication status. It flashes during communication and
may stay on when communication is good.
1.8 CR1225 battery
The cMT-SVR Series HMI requires a CR1225 coin type lithium battery to keep the RTC running.
Battery type: CR1225 3V lithium battery
1.9 Power connection
Power: The unit can be powered by DC power only, cMT-SVR-100/102 voltage range: 24±20%
Volts DC, cMT-SVR-200/202 voltage range: 10.5~28 Volts DC, compatible with most controller DC
systems.
Note: Connect positive DC line to the‘+’terminal and the DC ground to the‘-’terminal.
1.10 How to update cMT-SVR OS image
Copy the MTfirmware.bin file to SD card, insert the SD card to cMT-SVR and flip DIP Switch 2 to ON.
Restart cMT-SVR and wait about 2 minutes for the system to update OS image. To find the version
number of cMT-SVR OS, please log in System Setting as shown below. (Details can be found in later
chapters.)

UM015002E_20190123 Copyright© 2019 Weintek Lab., Inc. All rights reserved.
6

UM015002E_20190123 Copyright© 2019 Weintek Lab., Inc. All rights reserved.
7
Chapter 2 System Setting
Connect cMT-SVR via Ethernet cable or Wi-Fi, and configure system settings using the following two
ways.
Set in internet browser
Open internet browser (IE, Chrome, or Firefox), and enter cMT-SVR IP address (for example:
192.168.1.15/web_ihmi) to configure cMT-SVR.
Set on cMT Viewer devices
Launch cMT Viewer App, tap Search, select the cMT-SVR and tap icon to configure.

UM015002E_20190123 Copyright© 2019 Weintek Lab., Inc. All rights reserved.
8
2.1 cMT-SVR System Setting
2.1.1 Information
The following part introduces cMT-SVR system information.

UM015002E_20190123 Copyright© 2019 Weintek Lab., Inc. All rights reserved.
9
Icon
Description
Displays HMI name.
Displays current date.
Displays current time.
2.1.2 System Setting
The following part introduces cMT-SVR system setting.
There are two modes, [System setting] and [Update]. [System Setting] controls all the settings while
[Update] controls limited items. For safety, specify password for configuration. Enter password to
log in and then select [History] to back up history data.

UM015002E_20190123 Copyright© 2019 Weintek Lab., Inc. All rights reserved.
10
Network
Set the IP address of Ethernet port. cMT-SVR-100/102 has two Ethernet ports while
cMT-SVR-200/202 only has one.
Wi-Fi
cMT-SVR-200/202 can be connected via Wi-Fi. The settings page is shown below.

UM015002E_20190123 Copyright© 2019 Weintek Lab., Inc. All rights reserved.
11
Date/Time
Set time, or select [Sync with host.] to synchronize cMT-SVR time with PC time.
HMI Name
Enter a cMT-SVR name to identify the unit. This saves the trouble of remembering the IP address of
each unit. Click [Identification light] button to turn on the CPU light of the unit. The light flashes 3
times to help finding the unit.

UM015002E_20190123 Copyright© 2019 Weintek Lab., Inc. All rights reserved.
12
History
Clear or backup history data in cMT-SVR.
Email
Set the mail address and contact group.

UM015002E_20190123 Copyright© 2019 Weintek Lab., Inc. All rights reserved.
13
Project Management
Restart, update, or backup project file.
System Password
Set the password for login, and the password for transferring project file and history data.

UM015002E_20190123 Copyright© 2019 Weintek Lab., Inc. All rights reserved.
14
Enhanced Security
Set the privilege and password of the account.
EasyAccess 2.0
Activate EasyAccess 2.0 and configure proxy settings.

UM015002E_20190123 Copyright© 2019 Weintek Lab., Inc. All rights reserved.
15
Misc
Miscellaneous settings.

UM015002E_20190123 Copyright© 2019 Weintek Lab., Inc. All rights reserved.
16
Chapter 3 How to create a cMT-SVR project
3.1 Create a new project
Step 1. Launch EasyBuilder Pro and select cMT-SVR model.
Step 2. Create the needed objects on editing screen.
Step 3. Save the project and compile to *.cxob file.

UM015002E_20190123 Copyright© 2019 Weintek Lab., Inc. All rights reserved.
17
3.2 Download project to cMT-SVR
After compilation, a *.cxob file is generated. The file can be downloaded via Ethernet in EasyBuilder
Pro.
Or, in cMT-SVR System setting, tap Project Management \ Update Project to transfer the project file
from PC to cMT-SVR. Open internet browser (IE, Chrome, Firefox), enter cMT-SVR IP address (for
example: 192.168.1.118/web_ihmi), tap System setting, enter password, and then configure
cMT-SVR settings.

UM015002E_20190123 Copyright© 2019 Weintek Lab., Inc. All rights reserved.
18
Chapter 4 cMT Viewer App
cMT Viewer can connect and control cMT Series HMI models. The devices that support cMT Viewer
are: cMT-iV5 (Built-in), iPad/iPhone (Download from iOS® APP Store), AndroidTM (Download from
Google Play), Windows® (in EasyBuilder Pro installation directory).
Please note that:
1. Each cMT Viewer device can simultaneously connect with 4 cMT Series models.
2. Each cMT Viewer device can simultaneously monitor 50 cMT Series models (under Monitor
Mode).
3. Each cMT Series model can simultaneously connect with 1~10 cMT Viewer devices. In
EasyBuilder Pro, open System Parameters » Remote and set [Max. connet count].
4.1 Introduction of icons
Icon
Description
Tap this icon to run cMT Viewer App.
Tap the Start Button when running the project to return to cMT Viewer home
screen.
Tap this icon to configure cMT Viewer.
Tap this icon to change screen layout in Monitor Mode.
Tap this icon to search for all cMT Series HMIs on the same network.
Other manuals for cMT-SVR-100
1
This manual suits for next models
3
Table of contents
Other weintek Gateway manuals
Popular Gateway manuals by other brands

Blue Coat
Blue Coat ProxySG 300 Series quick start guide

ABB
ABB COM600 series Owner's/operator's manual

Motorola
Motorola CG4501 instruction manual

Telldus
Telldus TellStick Net quick guide

ZyXEL Communications
ZyXEL Communications PRESTIGE 2302RL - user guide

UfiSpace
UfiSpace T77I868.00 Quick reference guide

Arris
Arris Touchstone TG862G user guide

Allied Telesis
Allied Telesis AT-iMG646PX-ON Specifications

Nomadix
Nomadix AG 3100 user guide

Flint & Walling
Flint & Walling Z Control installation instructions

Ericsson
Ericsson EDACS Data Advantage Series Installation and Maintenance

Sercomm
Sercomm NA910A user guide