User-friendly
Manual
User Manual
Manual
del usuario
TENS, EMS AND
MASSAGE DEVICE
EQUIPO DE TENS, EMS Y MASAJES

Dok./Rev.-Nr. 196104_20180315
Contents
Overview ............................................................................. 3
Use........................................................................................4
Package contents/device parts.........................................6
General information ........................................................... 7
Reading and storing the user manual................................7
Explanation of symbols .........................................................7
Basic information....................................................................9
Safety................................................................................. 10
First steps ..........................................................................24
Initial inspection of package ..............................................24
Adhering the adhesive electrodes to the skin ................25
Changing the battery and battery information..............27
Overview of device functions ..........................................29
Application........................................................................ 31
Program overview................................................................ 31
Switching on the device ...................................................... 31
Procedure for fixed programs
TENS 1–27, EMS 1–7 and Massage 1–10.................................32
Procedure for fixed programs
TENS 28–30 and EMS 8–10................................................... 34
Steps for using the quick start programs.........................35
Preferred Program .............................................................. 36
Warnings, alarms and misapplications ............................37
Application programs.......................................................38
TENS application programs................................................ 38
EMS application programs.................................................. 41
Massage program................................................................ 43
Adhesive electrodes .........................................................44
Instructions for applying the adhesive electrodes....... 44
Placement of electrodes..................................................... 45
Placement of electrodes for EMS
(electrical muscle stimulation)...........................................47
Technical malfunctions..................................................... 52
Electrical interference immunity.....................................54
Cleaning and care of the TENS/EMS device .....................60
Notes on using the TENS/EMS device............................... 61
Technical data, symbols, pictograms ..............................62
Disposal .............................................................................64

A
3
12
3
4
5

B
C
4
14
13
12
11
6
7
8
9
10
15 16

D
5
EF
2
28
28
27
26
25
24
17
18
19
20
21
23 22

6
Package contents⁄device parts
1TEN 603 EMS/TENS device
2Belt clip
33× AAA batteries
44× adhesive electrodes
52× lead wires
6button
7button
8CH2 intensity button
9button
10 button
11 button
12 button
13 CH1 intensity button
14 button
15 Channel CH1 output jack
16 Channel CH2 output jack
17 Quick start mode
NECK/BACK/KNEE
18 Treatment duration in
minutes
19 Keypad lock symbol
20 Low battery symbol:
replace batteries
21 Output intensity for
channel CH2 (right)
22 Pulse length displayed in µs
23 Pulse frequency displayed
in Hz
24 Output intensity for
channel CH1 (left)
25 SET: Device is in
programming mode
26 Current program number
27 Therapy mode:
TENS/MASSAGE/EMS
28 Battery compartment cover
29 User manual

General information
7
General information
Reading and storing the user manual
This user manual accompanies this TENS, EMS and
massage device (hereinafter referred to only as
“TENS/EMS device”). It contains important information
on start-up and handling.
Before using the TENS/EMS device, read the user manual care-
fully. This particularly applies to the safety instructions. Failure
to heed this user manual may result in severe injury or dam-
age to the TENS/EMS device.
Store the user manual for future use. Make sure to include this
user manual when passing the TENS/EMS device on to third
parties.
Explanation of symbols
The following symbols and signal words are used in this user
manual, on the TENS/EMS device or on the packaging. The
safety symbols displayed in this user manual are instructions
on how to properly use the TENS/EMS device and are intended
for your safety.
DANGER!
This signal symbol/word indicates a hazard with high risk that,
if not avoided, results in death or a severe injury.

General information
8
WARNING!
This signal symbol/word designates a hazard with moderate
risk that, if not avoided, may result in death or severe injury.
CAUTION!
This signal symbol/word designates a hazard with low risk
that, if not avoided, may result in minor or moderate injury.
Read and observe the user manual!
Warning/danger: Improper use carries the risk of
serious injury, damage and risk to life!
These instructions must be followed!
Warning/danger: The device must not be used by
persons with pacemakers!

General information
9
IP 22 The first number 2: represents protection against
hard foreign objects with a diameter of .5 inches
(12.5 mm) or larger. The second number 2: represents
protection against drops of water falling vertically
when the housing is tilted by up to 15 degrees. Drops
of water falling at a perpendicular angle have no ef-
fect when the housing is tilted by up to 15 degrees.
Basic information
What are the features of a TENS/EMS device?
The TEN 603 TENS/EMS device is a device for electrical stimula-
tion. It conducts an electric current to the skin.
EMS (electrical muscle stimulation) = Muscle tissue is stimulated
electrically.
TENS (transcutaneous electrical nerve stimulation) =
The nerves are stimulated electrically.
This handy, convenient TENS/EMS device is used to electrically
stimulate targeted areas of the body.
Information on using TENS/EMS
The principle purpose of the TENS/EMS device is to stimulate
the nerves and muscles.
How does TENS work?
According to scientific theory, electrical stimulation therapy
works in several ways:
• The gentle electrical pulses travel through the skin to the
nearby nerves, blocking pain or rather preventing it from
reaching the brain from its point of origin.
• The gentle electrical pulses increase the body’s own
production of natural pain-reducing substances such as
endorphins.

Safety
10
• Furthermore, it can be assumed that the electrical stimu-
lation also stimulates blood flow. Muscles contract upon
contact with electrical stimulation and then expand. The
repeated contracting and relaxing causes the blood to flow
in and out, improving circulation.
How does EMS work?
The EMS device sends soothing pulses through the skin and
stimulates the nerves in the area being treated. When the
muscle receives this signal, it contracts as if the brain had sent
the signal itself. As the strength of the signal increases, the
muscle contracts in the same way as it does during exercise. If
the signal is interrupted, the muscle relaxes and the process
repeats. The goal of electrical muscle stimulation is contraction
or vibration in the muscles. Normal muscle activity is controlled
by the central and peripheral nervous system, which sends
electrical signals to the muscles. The EMS functions in a similar
way, but it uses an external source (stimulator) in combination
with electrodes placed on the skin to conduct the electrical
pulses into the body. The pulses stimulate the nerves so that
they send targeted signals to specific muscles, which then re-
act by contracting – just like during normal muscle activity.
Safety
General safety information
− If there is a defect, you must not repair, modify
(change) or use the TENS/EMS device. When
used incorrectly, the stimulation current can
lead to pain, injury or burns.

Safety
11
− If you experience skin changes, pain or swell-
ing, feel unwell, or experience any other
irregularities while using the TENS/EMS device,
stop using it immediately and consult your phy-
sician. Before using, remove all metal objects
such as jewelry, belts, wristwatches or other
accessories from your body in order to prevent
these from coming into contact with the TENS/
EMS device or the adhesive electrodes. Do not
use the TENS/EMS device while operating a car;
do not undertake any other activities during
use of the device.
− If you are not sure how to use the TENS/EMS de-
vice, you should consult your physician before
using it.
− In cases of unexplained pain, swollen muscles
or after a severe muscle injury, only use the
TENS/EMS device after consulting your physi-
cian. Use of the TENS/EMS device cannot replace
medical diagnosis and treatment.
− Keep this user manual for the entire service life
of the product for later consultation and include
it if you pass the TENS/EMS device on to third
parties. Make sure that the user manual is also
accessible to third parties. The user manual is a
component of the TENS/EMS device.
− Misuse and use other than the intended use
must be avoided.

Safety
12
− No equipment from other devices may be used.
− If irregularities arise during use, stop using the
device immediately.
− Neither the connecting cords nor the adhesive
electrodes may be bent at sharp angles.
− Do not place any heavy or sharp-edged objects
on the TENS/EMS device or the adhesive elec-
trodes.
− Check the device and the adhesive electrodes
for problems before every use. If a problem or
defect is present, the device and adhesive elec-
trodes must not be used.
− Never wear any body jewelry or adhesive tat-
toos in the area being stimulated during use of
the TENS/EMS device.
− Do not use the device on areas of the body that
are tattooed.
Proper use
Which use/application is the TENS/EMS
device suited for / in which environment
should it be used?
− Only use the TENS/EMS device for its intended
purpose, which is the external application of
low frequencies (electrical pulses in the range
of up to 150 Hz and up to 50 V) to the human
body.

Safety
13
− The TENS/EMS device is exclusively intended for
external use (application on the skin) in people
with the intention of stimulating the nerves and
muscles.
− The device may be used as part of TENS therapy
to treat pain in cases of acute pain, arthritis,
rheumatoid pain and other conditions causing
chronic pain.
− Unless instructed otherwise by a physician, we
recommend an average treatment time of 30
minutes, up to three times a day.
− The sensation of intensity varies widely from
day to day and can be adjusted by the user to
suit their needs through the TENS/EMS device’s
intensity control settings.
− TENS pain treatment using the TENS/EMS
device is purely symptomatic in nature. It can
contribute to a reduction in pain and, under
some circumstances, can aid recovery. If you
have questions about the therapy, consult your
physician.
− EMS applications using the TENS/EMS device
work to stimulate the muscles.

Safety
14
Which areas of application and use
are the TENS/EMS device not suited for / in
which setting should it not be used?
− The TENS/EMS device may not be used simul-
taneously with other medical and electrical
devices of any kind.
− Do not use the TENS/EMS device while show-
ering, swimming, using a sauna, bathing or
in any other environment with high humidity.
Keep all liquids away during use. Otherwise,
injury and detrimental health effects may result
due to increased stimulation or a short-circuit.
Attention! Risk to life!
− Do not use the TENS/EMS device in bed and/or
when sleeping. Do not use the TENS/EMS device
if easily flammable substances and gases or
explosives are nearby.
− During use, the TENS/EMS device may interfere
with other electric or electrical equipment.
Therefore, do not use the TENS/EMS device in
the vicinity of other electric devices.
− Do not use the TENS/EMS device within 1.5 me-
ters of a shortwave or microwave appliance or
a high-frequency electrosurgical device, as this
may result irritation or burning to the skin under
the electrodes. Do not use the TENS/EMS device
at altitudes of over 9,843 feet (3,000 meters).

Safety
15
− The TENS/EMS device is meant for personal
use only and is not intended for commercial or
industrial use.
− Please note that portable and mobile HF
(high-frequency) communication equipment
(e.g. mobile phones) may interfere with med-
ical electrical equipment. Medical electrical
devices are subject to special precautionary
measures with respect to the EMC (electromag-
netic compatibility). Therefore, please observe
the EMC notes concerning the installation and
start-up of the TENS/EMS device.
− You must not use the TENS/EMS device
under the following circumstances:
a. if you have cardiac disease or cardiac
arrhythmia (use can lead to cardiac arrest),
b. directly on a wound,
c. during pregnancy, near the uterus or during
labor,
d. near the eyes,
e. if you have a pacemaker,
f. on areas of the body with poor circulation,
g. if you have an emotional or mental disorder,
h. if you have been diagnosed with dementia
(mental deterioration),
i. if you have a low IQ (intelligence quotient).

Safety
16
− Under the following circumstances, you must
consult your physician before using the TENS/
EMS device:
a. acute illness,
b. tumors,
c. infectious disease,
d. fever,
e. blood-pressure conditions,
f. skin conditions,
g. following an accident,
h. nausea or dizziness,
i. disease outbreak,
j. as soon as irregularities arise,
k. pain from an unexplained source,
l. diabetes,
m. seizure disorders,
n. while menstruating,
o. if certain areas of the body are insensitive to
pain,
p. if you have metal or implants within your
body.
− In cases of non-specific pain such as general
headaches, treatment with the TENS/EMS de-
vice will be ineffective.
− Do not use the TENS/EMS device if you could
injure yourself in any way when startled sud-
denly.

Safety
17
− The adhesive electrodes of the TENS/EMS device
may not be used on open wounds, sensitive
areas of the skin, or fresh scars.
− The following persons should not use the TENS/
EMS device: children, persons at increased risk,
persons with allergies, persons with an immu-
nodeficiency, persons experiencing pain from
a unexplained cause, persons with diabetes or
circulatory system diseases, persons with poor
blood circulation in the exterior arteries and
tissues or severe cardiovascular disease. If in
doubt, ask your physician.
− The TENS/EMS device must not be used on
persons who cannot properly perceive electric
stimulation currents. Children are sensitive to
stimulation currents! Frail persons and those
with disabilities may not be able to notify others
when the stimulation current is too intense.
Use by children and young people
− This TENS/EMS device may not be used on children.
− The TENS/EMS device must be kept in a location
that is inaccessible to children and young peo-
ple under the age of 18.
− Ensure that the TENS/EMS device does not fall
into the hands of children. Children could ingest
the small parts and choke. Children could injure
themselves when using the device.

Safety
18
Notes on using the TENS/EMS device
− The adhesive electrodes may only be con-
nected to the TEN 603 TENS/EMS device. Please
ensure that the device is always switched off
when attaching or removing the adhesive
electrodes.
− Always switch off the device before reposition-
ing the adhesive electrodes of the TENS/EMS
device during use.
− Under some circumstances, use of the TENS/EMS
device can irritate the skin. If skin irritations arise
such as redness, blistering or itching, discontin-
ue use of the TENS/EMS device. Do not always
attach the adhesive electrodes in the exact same
locations, as this can lead to skin irritation.
Before using the device, you should thoroughly
cleanse and then dry the areas of the skin where
you intend to place the adhesive electrodes. The
skin should be clean and free of oils.
Do not connect the lead wires and adhesive elec-
trodes unless the TENS/EMS device is switched off.
− To avoid damaging the wires, do not pull on
them to disconnect them from the adhesive
electrode plug connections or from the device.
Always pull from the plugs when removing the
lead wires from the adhesive electrodes or the
device.

Safety
19
− The adhesive electrodes may be connected to
or disconnected from the device using the sock-
ets and the electric lead wire.
− Every person responds differently to electrical
nerve stimulation. If the treatment is unsuc-
cessful, consult your physician. Please remove
the protective film prior to attaching the adhe-
sive electrodes. The adhesive strength of the
electrodes depends on the characteristics of the
skin, storage, and number of times they have
been used. If the full surface of the adhesive
electrodes no longer adheres to the surface of
the skin, they need to be replaced with new
adhesive electrodes. The entire surface of the
adhesive electrodes must be in contact with the
skin in order to avoid a high local current den-
sity, which can lead to burning of the skin. After
use, reattach the adhesive electrodes to the
protective film and keep them in the polybag to
prevent them from drying out. This maintains
their ability to adhere.
− Avoid touching the adhesive electrodes during
use, as this can cause a short-circuit under
some circumstances, resulting in an excessive
current density. This excessive current density
can lead to burning and injury!

Safety
20
− DITTMANN textile electrodes, back belt, knee
cuff or neck collar, available as accessories, are
suitable for use with the TEN 603 TENS/EMS de-
vice for the application of special programs for
different body areas.
− When using these articles with the TEN 603
TENS/EMS, please observe the user manuals for
these articles, particularly their safety instruc-
tions.
Where may the adhesive electrodes be
applied?
− Every person responds differently to electrical
nerve stimulation. The electrodes therefore
need not be kept to specific areas. If the appli-
cation is unsuccessful, consult your physician
in order to determine what positioning tech-
niques are best suited for you.
− Familiarize yourself with the proper placement
of the adhesive electrodes using the instruc-
tions in the chapter “Adhering the adhesive
electrodes to the skin” and in the example illus-
trations in the chapter “Adhesive electrodes” for
both TENS and EMS use.
− Do not use adhesive electrodes which
are smaller than 1.57 × 1.57 in or 2.46 in²
(40 × 40 mm, or 16 cm²), as this could result
in an excessively high electricity density and
cause injury.
This manual suits for next models
1
Table of contents
Languages:
Other Welby Medical Equipment manuals
Popular Medical Equipment manuals by other brands

Getinge
Getinge Arjohuntleigh Nimbus 3 Professional Instructions for use

Mettler Electronics
Mettler Electronics Sonicator 730 Maintenance manual

Pressalit Care
Pressalit Care R1100 Mounting instruction

Denas MS
Denas MS DENAS-T operating manual

bort medical
bort medical ActiveColor quick guide

AccuVein
AccuVein AV400 user manual