Wellion CALLA classic User manual

OWNERS
GUIDE

2
Dear Wellion CALLA Classic Owner,
Thank you for choosing theWellion CALLA Classic Blood Glucose Monitoring
System to help you monitoring your blood sugar levels. We designed the
Wellion CALLA Classic Blood Glucose Monitoring System to be accurate and
easy to use.
Your new Wellion CALLA Classic Blood Glucose Monitoring System is
designed with convenience and accuracy in mind to make your life easier.
The No Code feature eliminates coding errors and ensures your test results
are accurate on every test. All of the information needed to use and maintain
your new meter is included in this manual. Please read it carefully.
Your Wellion CALLA Classic Blood Glucose Monitoring System
provides an easy and precise way to measure blood glucose
using fresh capillary whole blood taken from ngertips.

3
Testing is done outside the body (in vitro diagnostic use). The test results
are plasma-calibrated for easy comparison to lab results.
The Wellion CALLA Classic Blood Glucose Monitoring System is a portable
battery operated meter intended for use as an aid by persons with diabetes
and by health care professionals to monitor glucose concentration in whole
blood.
If you have questions or simply need more information, please call our
authorized representative or visit our website at www.wellion.at.
Thank you again for choosing the Wellion CALLA Classic Blood Glucose
Monitoring System.

4

5
TABLE OF CONTENTS
YOUR NEW BLOOD GLUCOSE KIT 7
The Wellion CALLA Classic Meter 8
The Wellion CALLA Blood Glucose Test Strip 10
Meter Display Screen
12
INSERTING (OR CHANGING) BATTERIES 13
CONTROL SOLUTION TESTING 15
Control Solution Trouble Shooting 21
TESTING YOUR BLOOD GLUCOSE 23
Preparing your Lancing device 24
Performing a Blood Glucose Test 26
UNDERSTANDING YOUR BLOOD GLUCOSE TEST RESULT 32
TABLE OF CONTENTS

6
TABLE OF CONTENTS
VIEWING YOUR METER’S MEMORY 33
CARING FOR THE METER 35
Cleaning the Meter 35
Storage and Precautions 35
SOLVING PROBLEMS 37
MANUFACTURER´S WARRANTY 41
SPECIFICATIONS 42
SYMBOLS 44

7
YOUR NEW BLOOD GLUCOSE KIT
The Wellion CALLA Classic Blood Glucose Monitoring System kit includes
the following items:
Wellion CALLA Classic blood glucose meter
10 Wellion CALLA test strips
Wellion Lancing device
10 Wellion Lancets
Compact Pouch
Easy Start Guide
YOUR NEW BLOOD GLUCOSE KIT

8
The Wellion CALLA Classic Meter
THE WELLION CALLA CLASSIC METER
Meter Display
Shows your blood glucose test
results and other messages.
Test Strip Port
Insert test strip to turn on the
meter.
Light Button
t 1SFTTGPSUIFMBTUTUPSFEUFTUWBMVFBOEUPTXJUDI
on the light.
t )PME BOE QSFTT UIF MJHIU CVUUPO UP UVSO Pò UIF
meter.

9
Battery Compartment
)PMETUXP"""CBUUFSJFT
The Wellion CALLA Classic Meter
THE WELLION CALLA CLASSIC METER

10
The Wellion CALLA Blood Glucose Test Strip
The Wellion CALLA Test Strips are glucose specic, biosensor-based test
strips that can test glucose in capillary whole blood in as quickly as 6
seconds and require very little blood sample.
The No Code feature eliminates error in testing caused by incorrect coding
or calibration procedure. The test result is plasma referenced for easy
comparison to lab results and has under-ll detection to alert you when
there is not enough blood to perform a test, so you can be assure that each
reading you get is an accurate and meaningful result.
THE WELLION CALLA BLOOD GLUCOSE TEST
STRIP
Contact Points
Insert this end to the
test strip port on the
meter.
Sampling End
Apply blood or control
solution here.

11
IMPORTANT:
t #FTVSFUPVTFPOMZUIF8FMMJPO$"--"#MPPE(MVDPTF5FTU4USJQXJUI
the Wellion CALLA Classic Blood Glucose Meter. Other brands of test
strips will not work with the Meter.
t 5IF8FMMJPO$"--"#MPPE(MVDPTF5FTU4USJQTBSFTFOTJUJWFUPNPJTUVSF
and light, it is important to close the vial cap of the test strip bottle
tightly after each use. DO NOT leave any test strips outside the bottle
while not in use.
t $BSFGVMMZEJTDBSEVTFEUFTUTUSJQTBOEMBODFUTJOQSPQFSXBTUFDPOUBJOFST
THE WELLION CALLA BLOOD GLUCOSE TEST
STRIP

12
METER DISPLAY SCREEN
Meter Display Screen
Reading unit icon
Meter failure icon
Invalid temperature
icon
Test strip icon Blood icon
Low battery icon
Reading,
Countdown message,
Error message
Memory recall icon
Control solution icon

13
INSERTING OR CHANGING BATTERIES
Batteries need to be inserted before using your Wellion CALLA Classic Me-
ter for the rst time or when the battery icon appears on the meter
display.
Materials you will need:
Your Wellion CALLA Classic Meter
Two Alkaline AAA Batteries (Supplied in Kit)
Step 1:
Unhook the hinge on the battery cover.
Step 2:
Insert new batteries according to the direction found
on inside the battery compartment. Place the battery
cover back into the meter rmly.
INSERTING OR CHANGING BATTERIES

14
INSERTING OR CHANGING BATTERIES
NOTE:
t 5IF TUPSFE SFTVMU XJMM OPU CF FSBTFE XIFO UIF CBUUFSJFT BSF CFJOH
changed.

15
CONTROL SOLUTION TESTING
CONTROL SOLUTION TESTING
The purpose of the control solution testing is to make sure the Wellion
CALLA Classic Blood Glucose Monitoring System is working properly.
You should perform control solution testing when:
t 6TJOHUIFNFUFSGPSUIFöSTUUJNF
t :PVPQFOBOFXCPUUMFPGUFTUTUSJQT
t :PVMFGUUIFDBQPOUIFUFTUTUSJQWJBMPQFOGPSBXIJMF
t :PVESPQQFEUIFNFUFS
t :PVTVTQFDUZPVSNFUFSBOEUFTUTUSJQTBSFOPUXPSLJOHQSPQFSMZ
t 5IFCMPPEHMVDPTFUFTUSFTVMUTEPOPUSFøFDUIPXZPVGFFM
t 1SBDUJDJOHUIFUFTUJOHQSPDFEVSF

16
CONTROL SOLUTION TESTING
IMPORTANT:
t 6TFPOMZUIF8FMMJPO$"--"(MVDPTF$POUSPM4PMVUJPOTXJUIUIF8FMMJPO
CALLA Test Strips. Other brands of control solution will produce
inaccurate results.
t "MXBZTDIFDLUIFFYQJSBUJPOEBUF%0/05VTFDPOUSPMTPMVUJPOTJG
FYQJSFE
t .BSLUIFOFXMZPQFOFECPUUMFPGDPOUSPMTPMVUJPOXJUIUIFEBUFPQFOFE
discard any unused control solution three months after opening.
t %0/05'3&&;&4UPSFUIFDPOUSPMTPMVUJPOTBUSPPNUFNQFSBUVSF
Materials you will need:
Your Wellion CALLA Classic Meter
Wellion CALLA Control Solution
A new Wellion CALLA Blood Glucose Test Strip

17
Step 1:
Insert a Wellion CALLA Blood Glucose Test Strip into the
meter with the arrow mark facing up. Make sure the
test strip contact points are inserted all the way into the
meter. Close the test strip bottle immediately after you
take out a strip.
CONTROL SOLUTION TESTING
IMPORTANT:
t %POPUVTFUFTUTUSJQUIBUIBTFYQJSFE$IFDLUIFFYQJSBUJPOEBUFUIBUJT
printed on the test strip bottle and its package.
t 6TFFBDIUFTUTUSJQJNNFEJBUFMZBGUFSSFNPWJOHJUGSPNUIFCPUUMF
t %POPUVTFXFUPSEBNBHFEUFTUTUSJQT
t ,FFQBXBZGSPNEJSFDUTVOMJHIUBOEIFBU4UPSFUIFUFTUTUSJQCPUUMFJO
a dry, cool place.

18
CONTROL SOLUTION TESTING
t 3FDPSEUIFvEBUFPQFOFEiPOUIFUFTUTUSJQCPUUMFMBCFMXIFOZPVöSTU
open it. 6 months after rst opened date, discard the bottle and any
remaining Test Strip.
t .BLFTVSFZPVBSFUFTUJOHCFUXFFO¡$¡$*GUIF.FUFSEJTQMBZT
NPWFUIFNFUFSJOUPBOBSFBUIBUJTCFUXFFO¡$¡$BOEBMMPX
10 to 15 minutes for it to reach the new temperature before use. Your
Meter will not begin testing if it’s outside this temperature range.
Step 2:
5IF NFUFS XJMM MJHIU VQ BOE TIPX B UFTU TUSJQ BOE øBTIJOH
blood drop icon. If other messages (Er 1, Er 2, etc) appear, see
Solving Problems on page 46 for trouble shooting.

19
CONTROL SOLUTION TESTING
Step 3:
Squeeze a drop of Wellion CALLA Control Solution onto a clean, dry,
nonabsorbent surface. Do not apply control solution to the test strip
directly from the bottle. Replace the bottle cap on the control solution
bottle immediately after use.
Step 4:
While holding the meter, touch the control solution to the
edge of the test strip, and the control solution would be
automatically sipped into the reaction area of the test strip.
)PMEUIFNFUFSVOUJMJUCFFQT
Step 5:
The screen will count down. After 6 seconds, the control solution testing
result will appear on the meter display screen.

20
CONTROL SOLUTION TESTING
Step 6:
Compare the reading on the screen to the corresponding control range
printed on the test strip bottle or its package. If the reading does not fall
within the ranges printed on the test strip bottle or
its package, see Control Solution Trouble Shooting
on page 21.
Step 7:
Remove and discard the used test strip into proper
XBTUFCBTLFU5IFNFUFSXJMMBVUPNBUJDBMMZTIVUPò
after the test strip has been removed, or will shut
PòBGUFSNJOVUFTPGOPOVTF
Perform other levels of control solution testing by repeating the above
steps.
Table of contents
Other Wellion Blood Glucose Meter manuals
Popular Blood Glucose Meter manuals by other brands

Arkray
Arkray Gluocard Shine Express user manual

Trividia Health
Trividia Health TRUE METRIX PRO user manual

Bayer HealthCare
Bayer HealthCare Breeze 2 user guide

TD
TD GLUCO TD-4277B user manual

EPS Bio Technology
EPS Bio Technology EasyPlus mini user manual

A. Menarini Diagnostics
A. Menarini Diagnostics GlucoMen Day Meter user guide

Trividia Health
Trividia Health TRUENESS AIR owner's booklet

iHealth
iHealth Gluco-Monitoring System owner's manual

TELCARE
TELCARE TCTM0001 user manual

ARA Pharmaceuticals
ARA Pharmaceuticals First Canadian Health SPIRIT owner's booklet

Linktop
Linktop HC-03U user manual

Roche
Roche Accu-Chek Aviva Expert How-to