Dear Wellion CALLA Mini Owner,
Thank you for choosing the Wellion CALLA Mini Blood Glucose Monitoring
System to help you monitoring your blood sugar levels. We designed the
Wellion CALLA Mini Blood Glucose Monitoring System to be accurate and
easy to use.
Your new Wellion CALLA Mini Blood Glucose Monitoring System is designed
with convenience and accuracy in mind to make your life easier. The No
Code feature eliminates coding errors and ensures your test results are
accurate on every test. All of the information needed to use and maintain
your new meter is included in this manual. Please read it carefully.
The Wellion CALLA Mini Blood Glucose Monitoring System is a portable
battery operated meter intended for use as an aid by persons with diabetes
and by health care professionals to monitor glucose concentration in whole
blood.

3
Intended Use: The Wellion CALLA Mini Blood Glucose Monitoring System
is intended for the quantitative measurement of glucose in fresh capillary
whole blood samples drawn from the fingertips. Testing is done outside
the body (in vitro diagnostic use). The Wellion CALLA Mini blood glucose
meter is intended for both self-testing use by people with diabetes and
professional use by healthcare professionals in a clinical setting, as an aid
to monitoring glucose levels in Diabetes Mellitus. It is not intended for
diagnosis of diabetes or for neonatal use.
IMPORTANT:
t%FIZESBUJPOo4FWFSFEFIZESBUJPONBZMFBEUPJOBDDVSBUFCMPPEHMVDPTF
test result. If you suspect you are severely dehydrated, contact your
healthcare professional immediately.
t)FNBUPDSJUSBOHFo"IFNBUPDSJUSBOHFUIBUJTIJHIFSUIBOPSMPXFS
UIBODBODBVTFJOBDDVSBUFCMPPEHMVDPTFUFTUSFTVMUT
t/PUJOUFOEFEGPSVTFPOOFPOBUFT
t1BUJFOUTVOEFSHPJOHPYZHFOUIFSBQZNBZSFDFJWFJOBDDVSBUFSFTVMUT

4
If you have questions or simply need more information, please call our
authorized representative or visit our website at www.medtrust.at
Thank you again for choosing the Wellion CALLA Mini Blood Glucose
Monitoring System.

YOUR NEW BLOOD GLUCOSE KIT
The Wellion CALLA Mini Blood Glucose Monitoring System kit includes the
following items:
Wellion CALLA Mini blood glucose meter
Wellion Lancing device
10 Wellion Lancets
Compact Pouch
User Guide
WELLION CALLA MINI

6
The Wellion CALLA Mini meter
WELLION CALLA MINI
Meter Display
Shows your blood glucose test
results, memory values, averages,
and other messages.
Test Strip Port
Insert test strip to turn on the
meter.
Scroll Buttons
Press the scroll buttons to go into setup mode during meter setting, to
navigate through stored test values and averages or when setting up the
meter.
OK Button
Press and hold to turn meter on
and off.

7
Battery Compartment
)PMET B 7 MJUIJVN CBUUFSZ
(CR2032).
Das Wellion CALLA Mini Messgerät
WELLION CALLA MINI
PC Connection Port
Plug in the data cable to transmit results onto a PC (Data cable and
software sold separately*).
*The correct reading of your data can be ensured only with the original Wellion CALLA USB cable with Micro-USB connector.-
xx000001

8
The Wellion CALLA Blood Glucose Test Strip
The Wellion CALLA Test Strips are glucose specific, biosensor-based test
strips that can test glucose in capillary whole blood in as quickly as 6 sec-
onds and require very little blood sample.
The No Code feature eliminates error in testing caused by incorrect coding
or calibration procedure. The test result is plasma referenced for easy
comparison to lab results. The meter has an under-fill detection to alert you
when there is not enough blood to perform a test, so you can be assure that
each reading you get is an accurate and meaningful result.
WELLION CALLA MINI
Contact Points
Insert this end to the test
strip port on the meter.
Sampling End
Apply blood or
control solution here

9
IMPORTANT:
t #FTVSFUPVTFPOMZUIF8FMMJPO$"--"#MPPE(MVDPTF5FTU4USJQXJUI
the Wellion CALLA Mini Blood Glucose Meter. Other brands of test
strips will not work with the Meter.
t 5IF8FMMJPO$"--"#MPPE(MVDPTF5FTU4USJQTBSFTFOTJUJWFUPNPJTUVSF
and light, it is important to close the vial cap of the test strip bottle
immediately tightly after each use. Keep the un-used test strips in the
original bottle. DO NOT leave any test strips outside the bottle while
not in use.
t %0/05SFVTFUFTUTUSJQT5FTUTUSJQTBSFGPSTJOHMFVTFPOMZ
t $BSFGVMMZEJTDBSEVTFEUFTUTUSJQTBOEMBODFUTJOQSPQFSXBTUFDPOUBJO-
ers.
WELLION CALLA MINI

10
WELLION CALLA MINI
Meter Display Screen
Blood drop Icon
(meter ready for testing)
Test result, stored
test results, averages,
countdown, messages
)PVS.JOVUFT
Temperature Icon
(too hot, too cold)
Low Battery Icon
Day Average Icon
Memory Icon
Units of measurement
Tone Icon
Alarm Clock Icon)BQQZ'BDF
(meter electronic
works properly)
Icon for control
solution mode
Test strip Icon
(meter is ready to
insert a test strip)

11
SETTING UP YOUR NEW SYSTEM
Inserting (or changing) batteries
Batteries need to be inserted before using your Wellion CALLA Mini Meter for
the first time or when the battery icon appears on the meter display.
Materials you will need:
Your Wellion CALLA Mini Meter
0OF$37-JUIJVNDPJODFMMCBUUFSZ4VQQMJFEJO,JU
Step 1:
Unhook the hinge on the battery cover.
Step 2:
Insert a new battery to the battery socket with the “+” side facing up.
Place the battery cover back into the meter firmly.
WELLION CALLA MINI
xx000001

12
WELLION CALLA MINI
NOTE:
t 5IFEBUFBOEUIFTUPSFESFTVMUTXJMMOPUCFFSBTFEXIFOUIFCBUUFSJFT
are being changed.
t 8IFOZPVDIBOHFUIFCBUUFSZUIFNFUFSBVUPNBUJDBMMZQSPNQUTZPV
to check the time and date, when you turn on the meter or insert a test
strip. If time and date are correct, press OK. If time and date are not
correct, set them to the correct values.
t %JTDBSEVTFECBUUFSJFTBDDPSEJOHUPZPVSMPDBMSFHVMBUJPO

13
WELLION CALLA MINI
Setting the clock
Material you will need:
Your Wellion CALLA Mini Meter
Step 1: Press and hold the OK button to turn on the meter.
Step 2: Release the OK button and the meter will run a system check
automatically. “-” will appear on the display before entering the main
mode.
If an error message appears, please refer to chapter“solving problems”
NOTE:
t *GEBUFBOEUJNFPOUIF8FMMJPO$"--".JOJ.FUFSIBTOPUCFFOTFU
test or control results will not be stored in the meter memory.

14
WELLION CALLA MINI
After a flashing test strip icon appears on the screen, press the arrow-button
YYY twice until you can see the clock-symbol .
Step 3 - Set Year:
Press the OK button to enter date and time set up. The current year will
flash. Use or buttons to select the correct year. Press the OK button
to confirm your choice and advance to set the month.
Step 4 - Set Month:
The current month will flash. Use or buttons to select the correct
month. Press the OK button to confirm your choice and to advance to set
the day.
4UFQ4FU%BZ
The current day will flash. Use or buttons to select the correct day.
Press the OK button to confirm your choice and to advance to set the time
format.

WELLION CALLA MINI
4UFQ4FU5JNFGPSNBUII5IFUJNFGPSNBUXJMMGMBTI6TFPS
XXX buttons to select the time format. Press the OK button to confirm your
choice and to advance to set the hour.
4UFQ4FU)PVS
The current hour will flash. Use or buttons to select the correct
hour. Press the OK button to confirm your choice and to advance to set the
minutes.
Step 8 - Set Minute:
The current minute will flash. Use or buttons to select the correct
NJOVUFT1SFTTUIF0,CVUUPOUPDPOGJSNZPVSDIPJDFBOEFYJUUJNFTFUVQ
Insert a test strip and begin testing, or turn off the meter by press and hold
UIF0,CVUUPOVOUJMUIFEJTQMBZTDSFFOTTIPXT0''

16
WELLION CALLA MINI
NOTE:
t "OZUJNFEVSJOHTFUVQJOTFSUJOHB$"--"5FTU4USJQXJMMCFHJOUFTUJOH
The changes you have done so far will be memorized by the meter.

17
WELLION CALLA MINI
5VSOJOH0/0''UPOFTPVOE
The Wellion CALLA Mini Meter comes with tone ON as preset. Turning off
the tone will cause you to miss many important cues from your meter - such
as confirmation or error messages.
Material you will need: Your Wellion CALLA Mini Meter
Step 1: Scroll through the settings for the tone setting, press OK button to
enter tone set up. The tone icon will be visible and the current tone
status will appear on the LCD screen.
Step 2: Use or buttons to turn the tone on or off. Press the OK but-
ton to confirm your choice.
Insert a test strip and begin testing, or turn off the meter by press and hold
UIF0,CVUUPOVOUJMUIFEJTQMBZTDSFFOTTIPXT0''

18
WELLION CALLA MINI
NOTE:
t "OZUJNFEVSJOHTFUVQJOTFSUJOHB$"--"5FTU4USJQXJMMCFHJOUFTUJOH
The changes you have made so far will be memorized by the meter.
Setting alarms
Your Wellion CALLA Mini Meter has 3 alarms that can be setup. The factory
QSFTFUJTPGGGPSBMMBMBSNT'PMMPXUIFTUFQTCFMPXUPTFUVQVQZPVSBMBSNT
Material you will need
Your Wellion CALLA Mini Meter
Step 1: Press or buttons in the settings menu until the alarm clock
flashes.

19
Step 2: Press the OK button and enter alarm setup for alarm number 1.
4UFQ5IFBDUVBMTUBUVT0''0/XJMMGMBTI
1SFTTPSCVUUPOTUPDIBOHFUIFTFUUJOHBOEUVSO0/0''BMBSN
Step 4: If ON is selected and you press the OK button, you will proceed with
setting the hour. Press the or to change the hour. Press OK to con-
firm your choice.
4UFQ1SFTTUIFPSUPDIBOHFUIFNJOVUF1SFTT0,UPDPOGJSNZPVS
choice.
WELLION CALLA MINI

20
WELLION CALLA MINI
NOTE:
t *G0''JTTFMFDUFEBOEUIF0,CVUUPOJTQSFTTFEZPVXJMMQSPDFFEUPTFU
UIFOFYUBMBSN
t "GUFSMFBWJOHUIFTFUUJOHTUIFBMBSNDMPDLJDPOXJMMBQQFBSQFSNBOFOU-
ly to indicate that an alarm was set.
CONTROL SOLUTION TESTING
The purpose of the control solution testing is to validate the performance
of the Wellion CALLA Mini Blood Glucose Monitoring System using the
testing solution with a known range of glucose.
You can perform control solution testing when:
t 6TJOHUIFNFUFSGPSUIFGJSTUUJNF
t :PVPQFOBOFXCPUUMFPGUFTUTUSJQT
t :PVMFGUUIFDBQPOUIFUFTUTUSJQWJBMPQFOGPSBXIJMF
Table of contents
Other Wellion Blood Glucose Meter manuals
Popular Blood Glucose Meter manuals by other brands

A.MENARINI
A.MENARINI GlucoMen Areo quick guide

Beurer medical
Beurer medical GL 50 manual

ForaCare
ForaCare Premium V10 owner's manual

ACCU-CHECK
ACCU-CHECK AVIVA COMBO Getting started guide

MHC Medical Products
MHC Medical Products EasyTouch BluLink Instructions for use

Bayer HealthCare
Bayer HealthCare Contour next EZ user guide