Wenger Lieto User manual

Important User Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Light Fixture Electrical Connection . . . . . . . . . . . . . . . . . . . . . . . . 3
Light Fixture Conguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Initial Conguration ................................4
Congure the DMXcat Connection ....................5
Lieto LED Light Fixture Communication ................5
Light Fixture Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Schematics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Additional Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Care and Maintenance .............................8
Storage Information ................................8
Troubleshooting ...................................8
DMX Address Information ...........................8
LED Power Settings Chart ..........................8
Owner’s Manual
Lieto
™
LED Light Fixture
©Wenger Corporation 2020 Printed in USA 2020-05 Part #188A559-01
Wenger Corporation, 555 Park Drive, P.O. Box 448, Owatonna, Minnesota 55060-0448
USA: (800) 4WENGER (493-6437) • Worldwide: +1-507-455-4100 • wengercorp.com
Contents
Note: Please read and understand these instructions before operating.
Note: If you need additional information, contact Wenger Corporation using the information below.
Visit the Lieto Light Fixture web page at wengercorp.com for more information.

2
Important User Information
General
Copyright © 2020 by Wenger Corporation
All rights reserved. No part of the contents of this manual may be reproduced, copied, or transmitted in any form or
by any means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage
and retrieval systems without the written permission of the publisher, unless it is for the purchaser's personal use.
Printed and bound in the United States of America.
The information in this manual is subject to change without notice and does not represent a commitment on the part of
Wenger Corporation. Wenger Corporation does not assume any responsibility for any errors that may appear in these
instructions.
In no event will Wenger Corporation be liable for technical or editorial omissions made herein, nor for direct, indirect,
special, incidental, or consequential damages resulting from the use or defect of these instructions.
The manufacturer reserves the right to change this product at any time.
The information in this document is not intended to cover all possible conditions and situations that might occur. The
end user must exercise caution and common sense when assembling or installing Wenger Corporation products. If any
questions or problems arise, call the Wenger Corporation at (800) 4WENGER (493-6437)
or +1-507-455-4100 worldwide.
Manufacturer
The Lieto™ LED Light Fixture is manufactured by:
Wenger Corporation
555 Park Drive
Owatonna, MN 55060
(800) 4WENGER (493-6437) • +1 (507) 455-4100
wengercorp.com
Intended Use
• This product is designed to be used in Wenger Acoustical Shells.
• The xture is not designed for use in environments that have any of the following:
- Damp or wet conditions IP20 rated
- Corrosive atmospheres
- Oil and/or chemical vapors
- Excessive dust or explosive gases
- Excessive heat or exposure to areas with high temperatures
- Exposure to surges in electrical power
• This product must be installed according to the procedures in this document.
Installation
• This installation and use must comply with local regulations and codes.
• All personnel (including all temporary workers) must read and understand these instructions.
Warranty
This product is guaranteed free of defects in materials and workmanship for ve full years from date of shipment.
A full warranty statement is available upon request.
Make sure that anyone working
with the Lieto LED light xture
has read and understands these
instructions.
Always observe and comply
with the Warnings and
Cautions posted on the system
equipment.
Failure to comply with Warnings
and Cautions in this document
can result in damage to property
or serious injury.
Safety Precautions
Throughout this document you may nd cautions and warnings which are dened as follows:
• WARNING: Failure to follow the instruction could result in serious injury or damage to property.
• CAUTION: Failure to follow the instruction could result in minor injury or damage to property.
Read all of these safety instructions before using the equipment.
!WARNING !WARNING !WARNING

3
Light Fixture Electrical Connection
Lieto LED Light Fixture Electrical Connection
1. Ensure the light xture power source is compliant with local electrical codes.
2. Connect the PowerCON and RJ-45 or XLR DMX cables to the corresponding ports on the rst light xture
control box.
3. Connect the PowerCON and RJ-45 or XLR DMX cable to the next light xture in the row.
Note: Ensure the supply voltage meets the Lieto LED light xture requirements before securing connections.
The Lieto light xture requires non-dimmed mains power in the range of 100-240VAC 50/60Hz.
4. Power up the light xture to ensure proper connections.
Lieto LED Light Fixture
Electrical Connection
Daisy Chain Multiple LED Lights
Row Mounted
Junction Box
LietoLieto Lieto
LEDLED LED
Light
Fixture
Light
Fixture
Light
Fixture
First
Light
Fixture
Light
Fixture
Terminator
Light
Fixture
PowerCON
In/Out
DMX
(RJ-45 or XLR)
First
Light
Fixture
To next
light xture
in the row
From row mounted
junction box
with integral tilt switch
PowerCON
In/Out
From house lighting
control system
From house
electrical power
distribution
Do not connect or disconnect the LED
PowerCON connector under load.
!CAUTION

4
Light Fixture Conguration
Initial Conguration
Note: Only the initial conguration procedure does not require an
active power connection to the light xture.
1. Remove the conguration tablet from the shipping container.
Power-up and register the tablet by following the tablet initial
start-up prompts.
2. After the tablet has been registered select the appstore icon,
select the search button in the top right corner and type
“Wenger” in the search bar, then select the orange search icon
on the right side of the keyboard.
Note: Global installations may need to be set to the United States
to search for the software.
3. Locate the Wenger programmer application then select “get”.
The app will begin to download and install on the tablet.
4. Insert the USB-B connector of the USB-A to USB-B cord
in the corresponding USB-B port on the light xture
control box.
5. Insert the USB-A connector of the
USB-A to USB-B cord in the
corresponding port of the
micro USB to USB adapter cord,
then insert the micro USB connector
of the adapter cord into the tablet’s
micro USB port next to the
power/lock button.
6. Select the Wenger app on the tablet home screen.
7. Once the app is open/running the diagnostic information window
for the currently connected light xture is displayed, view the
information and select “ok”.
8. If a change to any of the elds is necessary, select the eld,
enter the new value, the select “set”.
The adjustable elds are:
• Device Label (ex. Wenger xture)
• DMX Address (ex. 1-512)
• DMX Value (Ex. 0-100% or 0-255)
• Dimming Curve (incandescent, linear, s curve, or exponential)
• DMX Terminator (on/o)
• DMX Loss (0-101% or 0-256)
• LED Power (0-100% or 0-255)
9. If required, select “set factory defaults” to reset the elds listed
above to the original values assigned by the manufacturer.
Note: Pressing “set factory defaults” results in the LED power setting to
be set to its maximum value of 255, which is approximately
170W output.
Although this output wattage will not adversely aect the
Lieto xture, the LED power value should be changed to the
value correlating to the photometric layout output wattage for
each xture.
This is best done using the Wenger App, not DMXcat app.
10. Repeat this procedure for each required light xture.
Conguration Tablet
Micro USB to USB AdapterUSB-A to USB-B
Diagnostic Information Window

5
Light Fixture Conguration (continued)
Congure the DMXcat®Connection
To congure the DMXcat® device to communicate with the conguration tablet:
1. Gently insert the DMXCat’s 5-pin
XLR jack into the 5-Pin XLR panel
mount plug with the protruding pins
located on the light xture control box.
2. Turn on the conguration tablet,
once the home screen is displayed
select the appstore icon.
3. Select the search icon in the upper
corner of the screen, type “DMXcat”
in the search bar then select the
orange search icon, select “get”
to download the DMXcat app by
City Theatrical.
4. Select the empty circle on the bottom
of the screen to return to the tablet
home screen, then select the DMXcat app.
5. Once the app is open select the
settings icon located in the top right
corner of the screen, then select “device list”
located under the bluetooth device section.
6. Locate the required DMXcat serial number and
select it to establish a connection between the
conguration tablet and the device.
7. The LED status indicator on the device will continuously illuminate green once the connection is established.
8. Congure the xture to the required DMX/RDM address based on the site’s requirements.
9. If required, select and hold down the Link icon in the lower left corner of the screen to disconnect the
DMXcat device from the conguration tablet. Wait for the LED status indicator to ash four times before
disconnecting the device from the xture.
10. If additional information is required select the DMXcat info icon to view the information provided by
City Theatrical while using the conguration tablet.
Lieto LED Light Fixture Communication
The Lieto LED light xture is compatible with the following communication networks:
• ANSI E1.11-2008 (R2013) USITT DMX512-A
• ANSI E1.20-2010 RDM over DMX512 Networks
• ANSI E1.37-1-2012 Additional RDM Message Sets
The congurable settings are made via RDM commands, serial TTL commands, and the tablet programmer.
On-board xture monitoring such as temperature, power cycles, and hours of operation are also continuously
recorded.
Unpackaged DMXcat Connector
(Kit components may vary slightly)
DMXcat
XLR5F
Connector
Belt Clip, Screw
and
Splint Ring Safety Point
USB to
Micro USB
Cable
XLR5M to
XLR5M
Turnaround

6
Light Fixture Operation
To adjust the angle and orientation of the LED array, use the adjustment knobs located in the underside
of the light xture.
1. Loosen the adjustment knobs to change the LED array angle and orientation.
2. Use the knobs, to orient the LED array to the desired angle.
3. Tighten the adjustment knobs to secure the LED array in the new position.
Only tighten the adjustment knobs by hand.
Use of tooling could cause damage.
Adjustment
Knobs
!CAUTION

7
Schematics
Lieto LED Light Fixture Electrical Schematic (Diva®Acoustical Ceiling)
LED SCHEMATIC FOR WENGER
MANUALS& ES51089
8.50
11.00
L1L2
L3
L4
JUNCTION BOX
RED
TILT SWITCH
110/240
VAC
JUNCTION BOX
N1N2
N3
CIRCUIT 1
L NGL NGL NGL NG
LAMP 1 LAMP 2
LAMP 31 LAMP 32 LAMP 40
CIRCUIT 2
CIRCUIT 3
CIRCUIT 4
LAMP 21
LAMP 11
LAMP 22
LAMP 12
LAMP 30
LAMP 20
LAMP 10
N4
RED
L NGL NGL NGL NG
RELAY
NEUTRAL TERMINAL BLOCK
GROUND BAR
HOUSE POWER SUPPLIED
IN FIELD BY OTHERS
CIRCUIT 4
CIRCUIT 3
CIRCUIT 2
CIRCUIT 1
R A C E WAY
See applications
documents for
coil voltage
LED's for manual
8.50
11.00
RELAY
JUNCTION BOX
NEUTRAL TERMINAL BLOCK
L NGL NGL NGL NG
TILT SWITCH
110/240
VAC
L NGL NGL NGL NG
LAMP 40
LAMP 30
LAMP 20
LAMP 10
LAMP 32
LAMP 22
LAMP 12
LAMP 2 LAMP 1
LAMP 31
LAMP 21
LAMP 11
CIRCUIT 4
CIRCUIT 3
CIRCUIT 2
CIRCUIT 1
RED
RED
HOUSE POWER SUPPLIED
IN FIELD BY OTHERS
L1 L2 L3 L4 N1 N2 N3 N4
CIRCUIT 1
CIRCUIT 2
CIRCUIT 3
CIRCUIT 4
See applications
documents for
coil voltage
Lieto LED Light Fixture Electrical Schematic (Maestro®Acoustical Ceiling)

8
Additional Information
Care and Maintenance
Periodically remove dust and debris from the surface and lower light diuser for optimal appearance and
performance.
Storage Information
The light xture must be kept in the original shipping container in a clean and dry location if not installed/used.
The light xture must be stored in a controlled environment, with adequate air circulation, and be protected by
sunlight, dirt, water, and condensation.
The optimal storage temperature is: 32°F to 125°F (0°C to 51.67°C).
Troubleshooting
The Lieto LED light xture will default to “Full-On” when the unit has power but no control signal.
DMX Address Information
The Lieto White Fixture
requires 1 DMX Channel
The Lieto Color Fixture
requires 4 DMX Channels
Channel 1: Intensity (0-255) Channel 1: Red (0-255)
Channel 2: Green (0-255)
Channel 3: Blue (0-255)
Channel 4: White (0-255)
LED Power Settings Chart
Wattage Power Setting
(0-255)
75 80
100 130
125 167
150 205
170* 255*
* See step 9 on page 4.
The light xture must be disconnected
from the site’s power supply before
any maintenance is performed.
!WARNING
Table of contents
Other Wenger Light Fixture manuals
Popular Light Fixture manuals by other brands

Emos
Emos ZY2268 manual

RAB Lighting
RAB Lighting ALED 52W installation instructions

ProLights
ProLights Sunbar2000FC user manual

Blizzard Lighting
Blizzard Lighting TORRENT 90 manual

Larson Electronics
Larson Electronics IND-HR-UVC-EXS-R1-24-3L-120V-2X instruction manual

BEMKO
BEMKO BLK-066-400-4K-WH instructions