Installation and Maintenance
7
1. Safety Notice
WARNING
·Do not install the equipment in a location where there is danger of exposure to flammable gas leakage.
(A high concentration of flammable gas near the unit may result in fire)
·Install condensate drain piping according to the instructions in this manual.
(Inadequate piping may cause flooding).
·Tighten the flare nut according to the specifications with a torque wrench. (Tightening the flare nut beyond
specified torque may damage the flare nut).
CAUTION
·Installation should be performed by a qualified personnel. (Improper installation may cause water leakage
and damage, shock, or fire.)
·Install the unit according to the instructions given in this manual. (Incomplete installation may cause water
leakage and damage, electrical shock, or fire).
·Be sure to use the supplied or specified installation parts. (Use of other parts may result in a poor installation,
water leakage, shock, or fire).
·Install the air conditioner on a solid structure that can support the unit weight. ( Inadequate support or
incomplete installation may cause injury).
·Electrical work should be carried out in accordance with the installation manual and national and local
codes.(Insufficient capacity or incomplete electrical work may cause electrical shock, or fire).
·Be sure to use a dedicated power circuit. (Never use a power supply shared by another appliance).
·For wiring, use a cable long enough to cover the entire distance. Do not use an extension cord.
·Use the specified types of wires for electrical connections between the indoor and outdoor units. (Tightly
connect the wires so their terminals with no external stresses).
·Poor or loose connections may cause terminal overheating or fire.
·After connecting all the wiring be sure to secure the cables so that they do not put pressure on the electrical
covers or panels. (Install covers over the wires. Incomplete cover installation may cause terminal overheating,
electrical shock, or fire).
·When installing or relocating the system, be sure to keep the refrigerant circuit free from air (Air in the
refrigerant circuit may cause an abnormal pressure rise or rupture, resulting in injury).
·If any refrigerant has leaks out during the installation work, ventilate the room.
·After all installation is completed, check to make sure that no refrigerant is leaking out. ( Refrigerant produces
a toxic gas if exposed to flames).
·When making piping connection, do not let any debris or contaminants other than the specified refrigerant
get into refrigeration cycle. (Doing so will cause reduced performance, abnormal high pressure in the
refrigeration cycle, explosion and injury).
·Make sure that the equipment is properly grounded. Do not ground the unit to a utility pipe, lightning arrester,
or telephone grounding. Incomplete grounding may cause electrical shock. (A high surge current from
lightning or other sources may cause damage to the equipment).
·An earth leakage circuit breaker may be required depending on the site condition to prevent electrical shock.
·Disconnect the power supply before wiring, piping, or checking the unit.
·When moving the units, do not tilt the unit incline more than 45 degree. Pay attention to the sharp edges of the
air conditioner to avoid any injury.
·During wired controller installation, ensure that the length of the wire between the indoor unit and remote
controller is within 131 ft. (40 m).